Cargando…
Impact of digital positron emission tomography/computed tomography on the delineation of clinical target volume in advanced lung cancer
The present study investigated the differences between digital [18F]-Fluorodeoxyglucose (FDG) positron emission tomography [PET]/computed tomography [CT] (dPET/CT) and conventional PET/CT (cPET/CT) in delineating the clinical target volume (CTV) in patients with advanced lung cancer in the involved...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
D.A. Spandidos
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10666076/ https://www.ncbi.nlm.nih.gov/pubmed/38022846 http://dx.doi.org/10.3892/mco.2023.2698 |
_version_ | 1785138964434255872 |
---|---|
author | Makita, Kenji Hamamoto, Yasushi Kanzaki, Hiromitsu Nagasaki, Kei Miyagawa, Masao Kawaguchi, Naoto Okada, Tomohisa Kido, Teruhito Kozuki, Toshiyuki |
author_facet | Makita, Kenji Hamamoto, Yasushi Kanzaki, Hiromitsu Nagasaki, Kei Miyagawa, Masao Kawaguchi, Naoto Okada, Tomohisa Kido, Teruhito Kozuki, Toshiyuki |
author_sort | Makita, Kenji |
collection | PubMed |
description | The present study investigated the differences between digital [18F]-Fluorodeoxyglucose (FDG) positron emission tomography [PET]/computed tomography [CT] (dPET/CT) and conventional PET/CT (cPET/CT) in delineating the clinical target volume (CTV) in patients with advanced lung cancer in the involved field radiation therapy (IFRT) era. Patients with advanced lung cancer were scanned using two dual-imaging protocols (dPET/CT and cPET/CT). Two virtual delineations contoured with reference to dPET/CT and cPET/CT images were created for each patient by five radiation oncologists. Changes in the delineation of target volumes in each patient were examined. A total of 10 patients [male/female, 9/1; median age, 65 years (range, 58-80 years)] were enrolled between April 2020 and September 2020. Significant changes in the delineation of CTVs were uncommon between dPET/CT and cPET/CT. A notable increase in CTVn was observed in 10% of the patients (1/10; P<0.05; Smirnov-Grubbs analysis). In this patient, a node that was not assessed as lymph node metastasis when cPET/CT was used was assessed as lymph node metastasis when dPET/CT was used and was included in the CTVn by all five radiation oncologists. In patients with advanced lung cancer, notable changes in CTV delineations are uncommon, regardless of whether dPET/CT or cPET/CT is used. However, in some cases, CTVn delineation with reference to dPET/CT may improve the treatment outcomes of IFRT for advanced lung cancer. |
format | Online Article Text |
id | pubmed-10666076 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | D.A. Spandidos |
record_format | MEDLINE/PubMed |
spelling | pubmed-106660762023-11-06 Impact of digital positron emission tomography/computed tomography on the delineation of clinical target volume in advanced lung cancer Makita, Kenji Hamamoto, Yasushi Kanzaki, Hiromitsu Nagasaki, Kei Miyagawa, Masao Kawaguchi, Naoto Okada, Tomohisa Kido, Teruhito Kozuki, Toshiyuki Mol Clin Oncol Articles The present study investigated the differences between digital [18F]-Fluorodeoxyglucose (FDG) positron emission tomography [PET]/computed tomography [CT] (dPET/CT) and conventional PET/CT (cPET/CT) in delineating the clinical target volume (CTV) in patients with advanced lung cancer in the involved field radiation therapy (IFRT) era. Patients with advanced lung cancer were scanned using two dual-imaging protocols (dPET/CT and cPET/CT). Two virtual delineations contoured with reference to dPET/CT and cPET/CT images were created for each patient by five radiation oncologists. Changes in the delineation of target volumes in each patient were examined. A total of 10 patients [male/female, 9/1; median age, 65 years (range, 58-80 years)] were enrolled between April 2020 and September 2020. Significant changes in the delineation of CTVs were uncommon between dPET/CT and cPET/CT. A notable increase in CTVn was observed in 10% of the patients (1/10; P<0.05; Smirnov-Grubbs analysis). In this patient, a node that was not assessed as lymph node metastasis when cPET/CT was used was assessed as lymph node metastasis when dPET/CT was used and was included in the CTVn by all five radiation oncologists. In patients with advanced lung cancer, notable changes in CTV delineations are uncommon, regardless of whether dPET/CT or cPET/CT is used. However, in some cases, CTVn delineation with reference to dPET/CT may improve the treatment outcomes of IFRT for advanced lung cancer. D.A. Spandidos 2023-11-06 /pmc/articles/PMC10666076/ /pubmed/38022846 http://dx.doi.org/10.3892/mco.2023.2698 Text en Copyright: © Makita et al. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License (https://creativecommons.org/licenses/by-nc-nd/4.0/) , which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made. |
spellingShingle | Articles Makita, Kenji Hamamoto, Yasushi Kanzaki, Hiromitsu Nagasaki, Kei Miyagawa, Masao Kawaguchi, Naoto Okada, Tomohisa Kido, Teruhito Kozuki, Toshiyuki Impact of digital positron emission tomography/computed tomography on the delineation of clinical target volume in advanced lung cancer |
title | Impact of digital positron emission tomography/computed tomography on the delineation of clinical target volume in advanced lung cancer |
title_full | Impact of digital positron emission tomography/computed tomography on the delineation of clinical target volume in advanced lung cancer |
title_fullStr | Impact of digital positron emission tomography/computed tomography on the delineation of clinical target volume in advanced lung cancer |
title_full_unstemmed | Impact of digital positron emission tomography/computed tomography on the delineation of clinical target volume in advanced lung cancer |
title_short | Impact of digital positron emission tomography/computed tomography on the delineation of clinical target volume in advanced lung cancer |
title_sort | impact of digital positron emission tomography/computed tomography on the delineation of clinical target volume in advanced lung cancer |
topic | Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10666076/ https://www.ncbi.nlm.nih.gov/pubmed/38022846 http://dx.doi.org/10.3892/mco.2023.2698 |
work_keys_str_mv | AT makitakenji impactofdigitalpositronemissiontomographycomputedtomographyonthedelineationofclinicaltargetvolumeinadvancedlungcancer AT hamamotoyasushi impactofdigitalpositronemissiontomographycomputedtomographyonthedelineationofclinicaltargetvolumeinadvancedlungcancer AT kanzakihiromitsu impactofdigitalpositronemissiontomographycomputedtomographyonthedelineationofclinicaltargetvolumeinadvancedlungcancer AT nagasakikei impactofdigitalpositronemissiontomographycomputedtomographyonthedelineationofclinicaltargetvolumeinadvancedlungcancer AT miyagawamasao impactofdigitalpositronemissiontomographycomputedtomographyonthedelineationofclinicaltargetvolumeinadvancedlungcancer AT kawaguchinaoto impactofdigitalpositronemissiontomographycomputedtomographyonthedelineationofclinicaltargetvolumeinadvancedlungcancer AT okadatomohisa impactofdigitalpositronemissiontomographycomputedtomographyonthedelineationofclinicaltargetvolumeinadvancedlungcancer AT kidoteruhito impactofdigitalpositronemissiontomographycomputedtomographyonthedelineationofclinicaltargetvolumeinadvancedlungcancer AT kozukitoshiyuki impactofdigitalpositronemissiontomographycomputedtomographyonthedelineationofclinicaltargetvolumeinadvancedlungcancer |