Cargando…

Impact of digital positron emission tomography/computed tomography on the delineation of clinical target volume in advanced lung cancer

The present study investigated the differences between digital [18F]-Fluorodeoxyglucose (FDG) positron emission tomography [PET]/computed tomography [CT] (dPET/CT) and conventional PET/CT (cPET/CT) in delineating the clinical target volume (CTV) in patients with advanced lung cancer in the involved...

Descripción completa

Detalles Bibliográficos
Autores principales: Makita, Kenji, Hamamoto, Yasushi, Kanzaki, Hiromitsu, Nagasaki, Kei, Miyagawa, Masao, Kawaguchi, Naoto, Okada, Tomohisa, Kido, Teruhito, Kozuki, Toshiyuki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: D.A. Spandidos 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10666076/
https://www.ncbi.nlm.nih.gov/pubmed/38022846
http://dx.doi.org/10.3892/mco.2023.2698
_version_ 1785138964434255872
author Makita, Kenji
Hamamoto, Yasushi
Kanzaki, Hiromitsu
Nagasaki, Kei
Miyagawa, Masao
Kawaguchi, Naoto
Okada, Tomohisa
Kido, Teruhito
Kozuki, Toshiyuki
author_facet Makita, Kenji
Hamamoto, Yasushi
Kanzaki, Hiromitsu
Nagasaki, Kei
Miyagawa, Masao
Kawaguchi, Naoto
Okada, Tomohisa
Kido, Teruhito
Kozuki, Toshiyuki
author_sort Makita, Kenji
collection PubMed
description The present study investigated the differences between digital [18F]-Fluorodeoxyglucose (FDG) positron emission tomography [PET]/computed tomography [CT] (dPET/CT) and conventional PET/CT (cPET/CT) in delineating the clinical target volume (CTV) in patients with advanced lung cancer in the involved field radiation therapy (IFRT) era. Patients with advanced lung cancer were scanned using two dual-imaging protocols (dPET/CT and cPET/CT). Two virtual delineations contoured with reference to dPET/CT and cPET/CT images were created for each patient by five radiation oncologists. Changes in the delineation of target volumes in each patient were examined. A total of 10 patients [male/female, 9/1; median age, 65 years (range, 58-80 years)] were enrolled between April 2020 and September 2020. Significant changes in the delineation of CTVs were uncommon between dPET/CT and cPET/CT. A notable increase in CTVn was observed in 10% of the patients (1/10; P<0.05; Smirnov-Grubbs analysis). In this patient, a node that was not assessed as lymph node metastasis when cPET/CT was used was assessed as lymph node metastasis when dPET/CT was used and was included in the CTVn by all five radiation oncologists. In patients with advanced lung cancer, notable changes in CTV delineations are uncommon, regardless of whether dPET/CT or cPET/CT is used. However, in some cases, CTVn delineation with reference to dPET/CT may improve the treatment outcomes of IFRT for advanced lung cancer.
format Online
Article
Text
id pubmed-10666076
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher D.A. Spandidos
record_format MEDLINE/PubMed
spelling pubmed-106660762023-11-06 Impact of digital positron emission tomography/computed tomography on the delineation of clinical target volume in advanced lung cancer Makita, Kenji Hamamoto, Yasushi Kanzaki, Hiromitsu Nagasaki, Kei Miyagawa, Masao Kawaguchi, Naoto Okada, Tomohisa Kido, Teruhito Kozuki, Toshiyuki Mol Clin Oncol Articles The present study investigated the differences between digital [18F]-Fluorodeoxyglucose (FDG) positron emission tomography [PET]/computed tomography [CT] (dPET/CT) and conventional PET/CT (cPET/CT) in delineating the clinical target volume (CTV) in patients with advanced lung cancer in the involved field radiation therapy (IFRT) era. Patients with advanced lung cancer were scanned using two dual-imaging protocols (dPET/CT and cPET/CT). Two virtual delineations contoured with reference to dPET/CT and cPET/CT images were created for each patient by five radiation oncologists. Changes in the delineation of target volumes in each patient were examined. A total of 10 patients [male/female, 9/1; median age, 65 years (range, 58-80 years)] were enrolled between April 2020 and September 2020. Significant changes in the delineation of CTVs were uncommon between dPET/CT and cPET/CT. A notable increase in CTVn was observed in 10% of the patients (1/10; P<0.05; Smirnov-Grubbs analysis). In this patient, a node that was not assessed as lymph node metastasis when cPET/CT was used was assessed as lymph node metastasis when dPET/CT was used and was included in the CTVn by all five radiation oncologists. In patients with advanced lung cancer, notable changes in CTV delineations are uncommon, regardless of whether dPET/CT or cPET/CT is used. However, in some cases, CTVn delineation with reference to dPET/CT may improve the treatment outcomes of IFRT for advanced lung cancer. D.A. Spandidos 2023-11-06 /pmc/articles/PMC10666076/ /pubmed/38022846 http://dx.doi.org/10.3892/mco.2023.2698 Text en Copyright: © Makita et al. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License (https://creativecommons.org/licenses/by-nc-nd/4.0/) , which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.
spellingShingle Articles
Makita, Kenji
Hamamoto, Yasushi
Kanzaki, Hiromitsu
Nagasaki, Kei
Miyagawa, Masao
Kawaguchi, Naoto
Okada, Tomohisa
Kido, Teruhito
Kozuki, Toshiyuki
Impact of digital positron emission tomography/computed tomography on the delineation of clinical target volume in advanced lung cancer
title Impact of digital positron emission tomography/computed tomography on the delineation of clinical target volume in advanced lung cancer
title_full Impact of digital positron emission tomography/computed tomography on the delineation of clinical target volume in advanced lung cancer
title_fullStr Impact of digital positron emission tomography/computed tomography on the delineation of clinical target volume in advanced lung cancer
title_full_unstemmed Impact of digital positron emission tomography/computed tomography on the delineation of clinical target volume in advanced lung cancer
title_short Impact of digital positron emission tomography/computed tomography on the delineation of clinical target volume in advanced lung cancer
title_sort impact of digital positron emission tomography/computed tomography on the delineation of clinical target volume in advanced lung cancer
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10666076/
https://www.ncbi.nlm.nih.gov/pubmed/38022846
http://dx.doi.org/10.3892/mco.2023.2698
work_keys_str_mv AT makitakenji impactofdigitalpositronemissiontomographycomputedtomographyonthedelineationofclinicaltargetvolumeinadvancedlungcancer
AT hamamotoyasushi impactofdigitalpositronemissiontomographycomputedtomographyonthedelineationofclinicaltargetvolumeinadvancedlungcancer
AT kanzakihiromitsu impactofdigitalpositronemissiontomographycomputedtomographyonthedelineationofclinicaltargetvolumeinadvancedlungcancer
AT nagasakikei impactofdigitalpositronemissiontomographycomputedtomographyonthedelineationofclinicaltargetvolumeinadvancedlungcancer
AT miyagawamasao impactofdigitalpositronemissiontomographycomputedtomographyonthedelineationofclinicaltargetvolumeinadvancedlungcancer
AT kawaguchinaoto impactofdigitalpositronemissiontomographycomputedtomographyonthedelineationofclinicaltargetvolumeinadvancedlungcancer
AT okadatomohisa impactofdigitalpositronemissiontomographycomputedtomographyonthedelineationofclinicaltargetvolumeinadvancedlungcancer
AT kidoteruhito impactofdigitalpositronemissiontomographycomputedtomographyonthedelineationofclinicaltargetvolumeinadvancedlungcancer
AT kozukitoshiyuki impactofdigitalpositronemissiontomographycomputedtomographyonthedelineationofclinicaltargetvolumeinadvancedlungcancer