Optimal bi-planar gradient coil configurations for diamond nitrogen-vacancy based diffusion-weighted NMR experiments
INTRODUCTION: Diffusion weighting in optically detected magnetic resonance experiments involving diamond nitrogen-vacancy (NV) centers can provide valuable microstructural information. Bi-planar gradient coils employed for diffusion weighting afford excellent spatial access, essential for integratin...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10667408/ https://www.ncbi.nlm.nih.gov/pubmed/37578612 http://dx.doi.org/10.1007/s10334-023-01111-0 |
_version_ | 1785139242281730048 |
---|---|
author | Amrein, Philipp Bruckmaier, Fleming Jia, Feng Bucher, Dominik B. Zaitsev, Maxim Littin, Sebastian |
author_facet | Amrein, Philipp Bruckmaier, Fleming Jia, Feng Bucher, Dominik B. Zaitsev, Maxim Littin, Sebastian |
author_sort | Amrein, Philipp |
collection | PubMed |
description | INTRODUCTION: Diffusion weighting in optically detected magnetic resonance experiments involving diamond nitrogen-vacancy (NV) centers can provide valuable microstructural information. Bi-planar gradient coils employed for diffusion weighting afford excellent spatial access, essential for integrating the NV-NMR components. Nevertheless, owing to the polar tilt of roughly [Formula: see text] of the diamond NV center, the primary magnetic field direction must be taken into account accordingly. METHODS: To determine the most effective bi-planar gradient coil configurations, we conducted an investigation into the impact of various factors, including the square side length, surface separation, and surface orientation. This was accomplished by generating over 500 bi-planar surface configurations using automated methods. RESULTS: We successfully generated and evaluated coil layouts in terms of sensitivity and field accuracy. Interestingly, inclined bi-planar orientations close to the NV–NMR setup’s requirement, showed higher sensitivity for the transverse gradient channels than horizontal or vertical orientations. We fabricated a suitable solution as a three-channel bi-planar double-layered PCB system and experimentally validated the sensitivities at [Formula: see text] and [Formula: see text] for the transverse [Formula: see text] and [Formula: see text] gradients, and [Formula: see text] for the [Formula: see text] gradient. DISCUSSION: We found that the chosen relative bi-planar tilt of [Formula: see text] represents a reasonable compromise in terms of overall performance and allows for easier coil implementation with a straight, horizontal alignment within the overall experimental setup. |
format | Online Article Text |
id | pubmed-10667408 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-106674082023-08-14 Optimal bi-planar gradient coil configurations for diamond nitrogen-vacancy based diffusion-weighted NMR experiments Amrein, Philipp Bruckmaier, Fleming Jia, Feng Bucher, Dominik B. Zaitsev, Maxim Littin, Sebastian MAGMA Research Article INTRODUCTION: Diffusion weighting in optically detected magnetic resonance experiments involving diamond nitrogen-vacancy (NV) centers can provide valuable microstructural information. Bi-planar gradient coils employed for diffusion weighting afford excellent spatial access, essential for integrating the NV-NMR components. Nevertheless, owing to the polar tilt of roughly [Formula: see text] of the diamond NV center, the primary magnetic field direction must be taken into account accordingly. METHODS: To determine the most effective bi-planar gradient coil configurations, we conducted an investigation into the impact of various factors, including the square side length, surface separation, and surface orientation. This was accomplished by generating over 500 bi-planar surface configurations using automated methods. RESULTS: We successfully generated and evaluated coil layouts in terms of sensitivity and field accuracy. Interestingly, inclined bi-planar orientations close to the NV–NMR setup’s requirement, showed higher sensitivity for the transverse gradient channels than horizontal or vertical orientations. We fabricated a suitable solution as a three-channel bi-planar double-layered PCB system and experimentally validated the sensitivities at [Formula: see text] and [Formula: see text] for the transverse [Formula: see text] and [Formula: see text] gradients, and [Formula: see text] for the [Formula: see text] gradient. DISCUSSION: We found that the chosen relative bi-planar tilt of [Formula: see text] represents a reasonable compromise in terms of overall performance and allows for easier coil implementation with a straight, horizontal alignment within the overall experimental setup. Springer International Publishing 2023-08-14 2023 /pmc/articles/PMC10667408/ /pubmed/37578612 http://dx.doi.org/10.1007/s10334-023-01111-0 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Research Article Amrein, Philipp Bruckmaier, Fleming Jia, Feng Bucher, Dominik B. Zaitsev, Maxim Littin, Sebastian Optimal bi-planar gradient coil configurations for diamond nitrogen-vacancy based diffusion-weighted NMR experiments |
title | Optimal bi-planar gradient coil configurations for diamond nitrogen-vacancy based diffusion-weighted NMR experiments |
title_full | Optimal bi-planar gradient coil configurations for diamond nitrogen-vacancy based diffusion-weighted NMR experiments |
title_fullStr | Optimal bi-planar gradient coil configurations for diamond nitrogen-vacancy based diffusion-weighted NMR experiments |
title_full_unstemmed | Optimal bi-planar gradient coil configurations for diamond nitrogen-vacancy based diffusion-weighted NMR experiments |
title_short | Optimal bi-planar gradient coil configurations for diamond nitrogen-vacancy based diffusion-weighted NMR experiments |
title_sort | optimal bi-planar gradient coil configurations for diamond nitrogen-vacancy based diffusion-weighted nmr experiments |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10667408/ https://www.ncbi.nlm.nih.gov/pubmed/37578612 http://dx.doi.org/10.1007/s10334-023-01111-0 |
work_keys_str_mv | AT amreinphilipp optimalbiplanargradientcoilconfigurationsfordiamondnitrogenvacancybaseddiffusionweightednmrexperiments AT bruckmaierfleming optimalbiplanargradientcoilconfigurationsfordiamondnitrogenvacancybaseddiffusionweightednmrexperiments AT jiafeng optimalbiplanargradientcoilconfigurationsfordiamondnitrogenvacancybaseddiffusionweightednmrexperiments AT bucherdominikb optimalbiplanargradientcoilconfigurationsfordiamondnitrogenvacancybaseddiffusionweightednmrexperiments AT zaitsevmaxim optimalbiplanargradientcoilconfigurationsfordiamondnitrogenvacancybaseddiffusionweightednmrexperiments AT littinsebastian optimalbiplanargradientcoilconfigurationsfordiamondnitrogenvacancybaseddiffusionweightednmrexperiments |