Cargando…

A convenient scoring system to distinguish intrahepatic mass-forming cholangiocarcinoma from solitary colorectal liver metastasis based on magnetic resonance imaging features

OBJECTIVES: To develop and validate a diagnostic scoring system to differentiate intrahepatic mass-forming cholangiocarcinoma (IMCC) from solitary colorectal liver metastasis (CRLM). METHODS: A total of 366 patients (263 in the training cohort, 103 in the validation cohort) who underwent MRI examina...

Descripción completa

Detalles Bibliográficos
Autores principales: Shen, Keren, Mo, Weixing, Wang, Xiaojie, Shi, Dan, Qian, Wei, Sun, Jihong, Yu, Risheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10667410/
https://www.ncbi.nlm.nih.gov/pubmed/37392232
http://dx.doi.org/10.1007/s00330-023-09873-w
_version_ 1785139242781900800
author Shen, Keren
Mo, Weixing
Wang, Xiaojie
Shi, Dan
Qian, Wei
Sun, Jihong
Yu, Risheng
author_facet Shen, Keren
Mo, Weixing
Wang, Xiaojie
Shi, Dan
Qian, Wei
Sun, Jihong
Yu, Risheng
author_sort Shen, Keren
collection PubMed
description OBJECTIVES: To develop and validate a diagnostic scoring system to differentiate intrahepatic mass-forming cholangiocarcinoma (IMCC) from solitary colorectal liver metastasis (CRLM). METHODS: A total of 366 patients (263 in the training cohort, 103 in the validation cohort) who underwent MRI examination with pathologically proven either IMCC or CRLM from two centers were included. Twenty-eight MRI features were collected. Univariate analyses and multivariate logistic regression analyses were performed to identify independent predictors for distinguishing IMCC from solitary CRLM. The independent predictors were weighted over based on regression coefficients to build a scoring system. The overall score distribution was divided into three groups to show the diagnostic probability of CRLM. RESULTS: Six independent predictors, including hepatic capsular retraction, peripheral hepatic enhancement, vessel penetrating the tumor, upper abdominal lymphadenopathy, peripheral washout at the portal venous phase, and rim enhancement at the portal venous phase were included in the system. All predictors were assigned 1 point. At a cutoff of 3 points, AUCs for this score model were 0.948 and 0.903 with sensitivities of 96.5% and 92.0%, specificities of 84.4% and 71.7%, positive predictive values of 87.7% and 75.4%, negative predictive values of 95.4% and 90.5%, and accuracies of 90.9% and 81.6% for the training and validation cohorts, respectively. An increasing trend was shown in the diagnostic probability of CRLM among the three groups based on the score. CONCLUSIONS: The established scoring system is reliable and convenient for distinguishing IMCC from solitary CRLM using six MRI features. CLINICAL RELEVANCE STATEMENT: A reliable and convenient scoring system was developed to differentiate between intrahepatic mass-forming cholangiocarcinoma from solitary colorectal liver metastasis using six MRI features. KEY POINTS: • Characteristic MRI features were identified to distinguish intrahepatic mass-forming cholangiocarcinoma (IMCC) from solitary colorectal liver metastasis (CRLM). • A model to distinguish IMCC from solitary CRLM was created based on 6 features, including hepatic capsular retraction, upper abdominal lymphadenopathy, peripheral washout at the portal venous phase, rim enhancement at the portal venous phase, peripheral hepatic enhancement, and vessel penetrating the tumor. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00330-023-09873-w.
format Online
Article
Text
id pubmed-10667410
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-106674102023-07-01 A convenient scoring system to distinguish intrahepatic mass-forming cholangiocarcinoma from solitary colorectal liver metastasis based on magnetic resonance imaging features Shen, Keren Mo, Weixing Wang, Xiaojie Shi, Dan Qian, Wei Sun, Jihong Yu, Risheng Eur Radiol Hepatobiliary-Pancreas OBJECTIVES: To develop and validate a diagnostic scoring system to differentiate intrahepatic mass-forming cholangiocarcinoma (IMCC) from solitary colorectal liver metastasis (CRLM). METHODS: A total of 366 patients (263 in the training cohort, 103 in the validation cohort) who underwent MRI examination with pathologically proven either IMCC or CRLM from two centers were included. Twenty-eight MRI features were collected. Univariate analyses and multivariate logistic regression analyses were performed to identify independent predictors for distinguishing IMCC from solitary CRLM. The independent predictors were weighted over based on regression coefficients to build a scoring system. The overall score distribution was divided into three groups to show the diagnostic probability of CRLM. RESULTS: Six independent predictors, including hepatic capsular retraction, peripheral hepatic enhancement, vessel penetrating the tumor, upper abdominal lymphadenopathy, peripheral washout at the portal venous phase, and rim enhancement at the portal venous phase were included in the system. All predictors were assigned 1 point. At a cutoff of 3 points, AUCs for this score model were 0.948 and 0.903 with sensitivities of 96.5% and 92.0%, specificities of 84.4% and 71.7%, positive predictive values of 87.7% and 75.4%, negative predictive values of 95.4% and 90.5%, and accuracies of 90.9% and 81.6% for the training and validation cohorts, respectively. An increasing trend was shown in the diagnostic probability of CRLM among the three groups based on the score. CONCLUSIONS: The established scoring system is reliable and convenient for distinguishing IMCC from solitary CRLM using six MRI features. CLINICAL RELEVANCE STATEMENT: A reliable and convenient scoring system was developed to differentiate between intrahepatic mass-forming cholangiocarcinoma from solitary colorectal liver metastasis using six MRI features. KEY POINTS: • Characteristic MRI features were identified to distinguish intrahepatic mass-forming cholangiocarcinoma (IMCC) from solitary colorectal liver metastasis (CRLM). • A model to distinguish IMCC from solitary CRLM was created based on 6 features, including hepatic capsular retraction, upper abdominal lymphadenopathy, peripheral washout at the portal venous phase, rim enhancement at the portal venous phase, peripheral hepatic enhancement, and vessel penetrating the tumor. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00330-023-09873-w. Springer Berlin Heidelberg 2023-07-01 2023 /pmc/articles/PMC10667410/ /pubmed/37392232 http://dx.doi.org/10.1007/s00330-023-09873-w Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Hepatobiliary-Pancreas
Shen, Keren
Mo, Weixing
Wang, Xiaojie
Shi, Dan
Qian, Wei
Sun, Jihong
Yu, Risheng
A convenient scoring system to distinguish intrahepatic mass-forming cholangiocarcinoma from solitary colorectal liver metastasis based on magnetic resonance imaging features
title A convenient scoring system to distinguish intrahepatic mass-forming cholangiocarcinoma from solitary colorectal liver metastasis based on magnetic resonance imaging features
title_full A convenient scoring system to distinguish intrahepatic mass-forming cholangiocarcinoma from solitary colorectal liver metastasis based on magnetic resonance imaging features
title_fullStr A convenient scoring system to distinguish intrahepatic mass-forming cholangiocarcinoma from solitary colorectal liver metastasis based on magnetic resonance imaging features
title_full_unstemmed A convenient scoring system to distinguish intrahepatic mass-forming cholangiocarcinoma from solitary colorectal liver metastasis based on magnetic resonance imaging features
title_short A convenient scoring system to distinguish intrahepatic mass-forming cholangiocarcinoma from solitary colorectal liver metastasis based on magnetic resonance imaging features
title_sort convenient scoring system to distinguish intrahepatic mass-forming cholangiocarcinoma from solitary colorectal liver metastasis based on magnetic resonance imaging features
topic Hepatobiliary-Pancreas
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10667410/
https://www.ncbi.nlm.nih.gov/pubmed/37392232
http://dx.doi.org/10.1007/s00330-023-09873-w
work_keys_str_mv AT shenkeren aconvenientscoringsystemtodistinguishintrahepaticmassformingcholangiocarcinomafromsolitarycolorectallivermetastasisbasedonmagneticresonanceimagingfeatures
AT moweixing aconvenientscoringsystemtodistinguishintrahepaticmassformingcholangiocarcinomafromsolitarycolorectallivermetastasisbasedonmagneticresonanceimagingfeatures
AT wangxiaojie aconvenientscoringsystemtodistinguishintrahepaticmassformingcholangiocarcinomafromsolitarycolorectallivermetastasisbasedonmagneticresonanceimagingfeatures
AT shidan aconvenientscoringsystemtodistinguishintrahepaticmassformingcholangiocarcinomafromsolitarycolorectallivermetastasisbasedonmagneticresonanceimagingfeatures
AT qianwei aconvenientscoringsystemtodistinguishintrahepaticmassformingcholangiocarcinomafromsolitarycolorectallivermetastasisbasedonmagneticresonanceimagingfeatures
AT sunjihong aconvenientscoringsystemtodistinguishintrahepaticmassformingcholangiocarcinomafromsolitarycolorectallivermetastasisbasedonmagneticresonanceimagingfeatures
AT yurisheng aconvenientscoringsystemtodistinguishintrahepaticmassformingcholangiocarcinomafromsolitarycolorectallivermetastasisbasedonmagneticresonanceimagingfeatures
AT shenkeren convenientscoringsystemtodistinguishintrahepaticmassformingcholangiocarcinomafromsolitarycolorectallivermetastasisbasedonmagneticresonanceimagingfeatures
AT moweixing convenientscoringsystemtodistinguishintrahepaticmassformingcholangiocarcinomafromsolitarycolorectallivermetastasisbasedonmagneticresonanceimagingfeatures
AT wangxiaojie convenientscoringsystemtodistinguishintrahepaticmassformingcholangiocarcinomafromsolitarycolorectallivermetastasisbasedonmagneticresonanceimagingfeatures
AT shidan convenientscoringsystemtodistinguishintrahepaticmassformingcholangiocarcinomafromsolitarycolorectallivermetastasisbasedonmagneticresonanceimagingfeatures
AT qianwei convenientscoringsystemtodistinguishintrahepaticmassformingcholangiocarcinomafromsolitarycolorectallivermetastasisbasedonmagneticresonanceimagingfeatures
AT sunjihong convenientscoringsystemtodistinguishintrahepaticmassformingcholangiocarcinomafromsolitarycolorectallivermetastasisbasedonmagneticresonanceimagingfeatures
AT yurisheng convenientscoringsystemtodistinguishintrahepaticmassformingcholangiocarcinomafromsolitarycolorectallivermetastasisbasedonmagneticresonanceimagingfeatures