Cargando…
Dynamic cardiac MRI with high spatiotemporal resolution using accelerated spiral-out and spiral-in/out bSSFP pulse sequences at 1.5 T
OBJECTIVE: To develop two spiral-based bSSFP pulse sequences combined with L + S reconstruction for accelerated ungated, free-breathing dynamic cardiac imaging at 1.5 T. MATERIALS AND METHODS: Tiny golden angle rotated spiral-out and spiral-in/out bSSFP sequences combined with view-sharing (VS), com...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10667461/ https://www.ncbi.nlm.nih.gov/pubmed/37665502 http://dx.doi.org/10.1007/s10334-023-01116-9 |
_version_ | 1785139254827941888 |
---|---|
author | Wang, Zhixing Feng, Xue Salerno, Michael Kramer, Christopher M. Meyer, Craig H. |
author_facet | Wang, Zhixing Feng, Xue Salerno, Michael Kramer, Christopher M. Meyer, Craig H. |
author_sort | Wang, Zhixing |
collection | PubMed |
description | OBJECTIVE: To develop two spiral-based bSSFP pulse sequences combined with L + S reconstruction for accelerated ungated, free-breathing dynamic cardiac imaging at 1.5 T. MATERIALS AND METHODS: Tiny golden angle rotated spiral-out and spiral-in/out bSSFP sequences combined with view-sharing (VS), compressed sensing (CS), and low-rank plus sparse (L + S) reconstruction were evaluated and compared via simulation and in vivo dynamic cardiac imaging studies. The proposed methods were then validated against the standard cine, in terms of quantitative image assessment and qualitative quality rating. RESULTS: The L + S method yielded the least residual artifacts and the best image sharpness among the three methods. Both spiral cine techniques showed clinically diagnostic images (score > 3). Compared to standard cine, there were significant differences in global image quality and edge sharpness for spiral cine techniques, while there was significant difference in image contrast for the spiral-out cine but no significant difference for the spiral-in/out cine. There was good agreement in left ventricular ejection fraction for both the spiral-out cine (− 1.6 [Formula: see text] 3.1%) and spiral-in/out cine (− 1.5 [Formula: see text] 2.8%) against standard cine. DISCUSSION: Compared to the time-consuming standard cine (~ 5 min) which requires ECG-gating and breath-holds, the proposed spiral bSSFP sequences achieved ungated, free-breathing cardiac movies at a similar spatial (1.5 × 1.5 × 8 mm(3)) and temporal resolution (36 ms) per slice for whole heart coverage (10–15 slices) within 45 s, suggesting the clinical potential for improved patient comfort or for imaging patients with arrhythmias or who cannot hold their breath. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s10334-023-01116-9. |
format | Online Article Text |
id | pubmed-10667461 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-106674612023-09-04 Dynamic cardiac MRI with high spatiotemporal resolution using accelerated spiral-out and spiral-in/out bSSFP pulse sequences at 1.5 T Wang, Zhixing Feng, Xue Salerno, Michael Kramer, Christopher M. Meyer, Craig H. MAGMA Research Article OBJECTIVE: To develop two spiral-based bSSFP pulse sequences combined with L + S reconstruction for accelerated ungated, free-breathing dynamic cardiac imaging at 1.5 T. MATERIALS AND METHODS: Tiny golden angle rotated spiral-out and spiral-in/out bSSFP sequences combined with view-sharing (VS), compressed sensing (CS), and low-rank plus sparse (L + S) reconstruction were evaluated and compared via simulation and in vivo dynamic cardiac imaging studies. The proposed methods were then validated against the standard cine, in terms of quantitative image assessment and qualitative quality rating. RESULTS: The L + S method yielded the least residual artifacts and the best image sharpness among the three methods. Both spiral cine techniques showed clinically diagnostic images (score > 3). Compared to standard cine, there were significant differences in global image quality and edge sharpness for spiral cine techniques, while there was significant difference in image contrast for the spiral-out cine but no significant difference for the spiral-in/out cine. There was good agreement in left ventricular ejection fraction for both the spiral-out cine (− 1.6 [Formula: see text] 3.1%) and spiral-in/out cine (− 1.5 [Formula: see text] 2.8%) against standard cine. DISCUSSION: Compared to the time-consuming standard cine (~ 5 min) which requires ECG-gating and breath-holds, the proposed spiral bSSFP sequences achieved ungated, free-breathing cardiac movies at a similar spatial (1.5 × 1.5 × 8 mm(3)) and temporal resolution (36 ms) per slice for whole heart coverage (10–15 slices) within 45 s, suggesting the clinical potential for improved patient comfort or for imaging patients with arrhythmias or who cannot hold their breath. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s10334-023-01116-9. Springer International Publishing 2023-09-04 2023 /pmc/articles/PMC10667461/ /pubmed/37665502 http://dx.doi.org/10.1007/s10334-023-01116-9 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Research Article Wang, Zhixing Feng, Xue Salerno, Michael Kramer, Christopher M. Meyer, Craig H. Dynamic cardiac MRI with high spatiotemporal resolution using accelerated spiral-out and spiral-in/out bSSFP pulse sequences at 1.5 T |
title | Dynamic cardiac MRI with high spatiotemporal resolution using accelerated spiral-out and spiral-in/out bSSFP pulse sequences at 1.5 T |
title_full | Dynamic cardiac MRI with high spatiotemporal resolution using accelerated spiral-out and spiral-in/out bSSFP pulse sequences at 1.5 T |
title_fullStr | Dynamic cardiac MRI with high spatiotemporal resolution using accelerated spiral-out and spiral-in/out bSSFP pulse sequences at 1.5 T |
title_full_unstemmed | Dynamic cardiac MRI with high spatiotemporal resolution using accelerated spiral-out and spiral-in/out bSSFP pulse sequences at 1.5 T |
title_short | Dynamic cardiac MRI with high spatiotemporal resolution using accelerated spiral-out and spiral-in/out bSSFP pulse sequences at 1.5 T |
title_sort | dynamic cardiac mri with high spatiotemporal resolution using accelerated spiral-out and spiral-in/out bssfp pulse sequences at 1.5 t |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10667461/ https://www.ncbi.nlm.nih.gov/pubmed/37665502 http://dx.doi.org/10.1007/s10334-023-01116-9 |
work_keys_str_mv | AT wangzhixing dynamiccardiacmriwithhighspatiotemporalresolutionusingacceleratedspiraloutandspiralinoutbssfppulsesequencesat15t AT fengxue dynamiccardiacmriwithhighspatiotemporalresolutionusingacceleratedspiraloutandspiralinoutbssfppulsesequencesat15t AT salernomichael dynamiccardiacmriwithhighspatiotemporalresolutionusingacceleratedspiraloutandspiralinoutbssfppulsesequencesat15t AT kramerchristopherm dynamiccardiacmriwithhighspatiotemporalresolutionusingacceleratedspiraloutandspiralinoutbssfppulsesequencesat15t AT meyercraigh dynamiccardiacmriwithhighspatiotemporalresolutionusingacceleratedspiraloutandspiralinoutbssfppulsesequencesat15t |