Cargando…

Quantification of pyruvate in-vitro using mid-infrared spectroscopy: Developing a system for microdialysis monitoring in traumatic brain injury patients

INTRODUCTION: Complex metabolic disruption is a major aspect of the pathophysiology of traumatic brain injury (TBI). Pyruvate is an intermediate in glucose metabolism and considered one of the most clinically informative metabolites during neurocritical care of TBI patients, especially in deducing t...

Descripción completa

Detalles Bibliográficos
Autores principales: Zimphango, Chisomo, Alimagham, Farah C., Hutter, Tanya, Hutchinson, Peter J., Carpenter, Keri L.H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10668092/
https://www.ncbi.nlm.nih.gov/pubmed/38021004
http://dx.doi.org/10.1016/j.bas.2023.102686
_version_ 1785139396423450624
author Zimphango, Chisomo
Alimagham, Farah C.
Hutter, Tanya
Hutchinson, Peter J.
Carpenter, Keri L.H.
author_facet Zimphango, Chisomo
Alimagham, Farah C.
Hutter, Tanya
Hutchinson, Peter J.
Carpenter, Keri L.H.
author_sort Zimphango, Chisomo
collection PubMed
description INTRODUCTION: Complex metabolic disruption is a major aspect of the pathophysiology of traumatic brain injury (TBI). Pyruvate is an intermediate in glucose metabolism and considered one of the most clinically informative metabolites during neurocritical care of TBI patients, especially in deducing the lactate/pyruvate ratio (LPR) – a widely-used metric for probing the brain's metabolic redox state. LPR is conventionally measured offline on a bedside analyzer, on hourly accumulations of brain microdialysate. However, there is increasing interest within the field to quantify microdialysate pyruvate and LPR continuously in near-real-time within its pathophysiological range. We have previously measured pure standard pyruvate in-vitro using mid-infrared transmission, employing a commercially available external cavity-quantum cascade laser (EC-QCL) and a microfluidic flow cell and reported a limit of detection (LOD) of 0.1 mM. RESEARCH QUESTION: The present study was to test whether the current commercially available state-of-the-art mid-infrared transmission system, can detect pyruvate levels lower than previously reported. MATERIALS AND METHODS: We measured pyruvate in perfusion fluid on the mid-infrared transmission system also equipped with an EC-QCL and microfluidic flow cells, tested at three pathlengths. RESULTS: We characterised the system to extract its relevant figures-of-merit and report the LOD of 0.07 mM. DISCUSSION AND CONCLUSION: The reported LOD of 0.07 mM represents a clinically recognised threshold and is the lowest value reported in the field for a sensor that can be coupled to microdialysis. While work is ongoing for a definitive evaluation of the system to measuring pyruvate, these preliminary results set a good benchmark and reference against which future developments can be examined.
format Online
Article
Text
id pubmed-10668092
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-106680922023-10-11 Quantification of pyruvate in-vitro using mid-infrared spectroscopy: Developing a system for microdialysis monitoring in traumatic brain injury patients Zimphango, Chisomo Alimagham, Farah C. Hutter, Tanya Hutchinson, Peter J. Carpenter, Keri L.H. Brain Spine Article INTRODUCTION: Complex metabolic disruption is a major aspect of the pathophysiology of traumatic brain injury (TBI). Pyruvate is an intermediate in glucose metabolism and considered one of the most clinically informative metabolites during neurocritical care of TBI patients, especially in deducing the lactate/pyruvate ratio (LPR) – a widely-used metric for probing the brain's metabolic redox state. LPR is conventionally measured offline on a bedside analyzer, on hourly accumulations of brain microdialysate. However, there is increasing interest within the field to quantify microdialysate pyruvate and LPR continuously in near-real-time within its pathophysiological range. We have previously measured pure standard pyruvate in-vitro using mid-infrared transmission, employing a commercially available external cavity-quantum cascade laser (EC-QCL) and a microfluidic flow cell and reported a limit of detection (LOD) of 0.1 mM. RESEARCH QUESTION: The present study was to test whether the current commercially available state-of-the-art mid-infrared transmission system, can detect pyruvate levels lower than previously reported. MATERIALS AND METHODS: We measured pyruvate in perfusion fluid on the mid-infrared transmission system also equipped with an EC-QCL and microfluidic flow cells, tested at three pathlengths. RESULTS: We characterised the system to extract its relevant figures-of-merit and report the LOD of 0.07 mM. DISCUSSION AND CONCLUSION: The reported LOD of 0.07 mM represents a clinically recognised threshold and is the lowest value reported in the field for a sensor that can be coupled to microdialysis. While work is ongoing for a definitive evaluation of the system to measuring pyruvate, these preliminary results set a good benchmark and reference against which future developments can be examined. Elsevier 2023-10-11 /pmc/articles/PMC10668092/ /pubmed/38021004 http://dx.doi.org/10.1016/j.bas.2023.102686 Text en © 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Zimphango, Chisomo
Alimagham, Farah C.
Hutter, Tanya
Hutchinson, Peter J.
Carpenter, Keri L.H.
Quantification of pyruvate in-vitro using mid-infrared spectroscopy: Developing a system for microdialysis monitoring in traumatic brain injury patients
title Quantification of pyruvate in-vitro using mid-infrared spectroscopy: Developing a system for microdialysis monitoring in traumatic brain injury patients
title_full Quantification of pyruvate in-vitro using mid-infrared spectroscopy: Developing a system for microdialysis monitoring in traumatic brain injury patients
title_fullStr Quantification of pyruvate in-vitro using mid-infrared spectroscopy: Developing a system for microdialysis monitoring in traumatic brain injury patients
title_full_unstemmed Quantification of pyruvate in-vitro using mid-infrared spectroscopy: Developing a system for microdialysis monitoring in traumatic brain injury patients
title_short Quantification of pyruvate in-vitro using mid-infrared spectroscopy: Developing a system for microdialysis monitoring in traumatic brain injury patients
title_sort quantification of pyruvate in-vitro using mid-infrared spectroscopy: developing a system for microdialysis monitoring in traumatic brain injury patients
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10668092/
https://www.ncbi.nlm.nih.gov/pubmed/38021004
http://dx.doi.org/10.1016/j.bas.2023.102686
work_keys_str_mv AT zimphangochisomo quantificationofpyruvateinvitrousingmidinfraredspectroscopydevelopingasystemformicrodialysismonitoringintraumaticbraininjurypatients
AT alimaghamfarahc quantificationofpyruvateinvitrousingmidinfraredspectroscopydevelopingasystemformicrodialysismonitoringintraumaticbraininjurypatients
AT huttertanya quantificationofpyruvateinvitrousingmidinfraredspectroscopydevelopingasystemformicrodialysismonitoringintraumaticbraininjurypatients
AT hutchinsonpeterj quantificationofpyruvateinvitrousingmidinfraredspectroscopydevelopingasystemformicrodialysismonitoringintraumaticbraininjurypatients
AT carpenterkerilh quantificationofpyruvateinvitrousingmidinfraredspectroscopydevelopingasystemformicrodialysismonitoringintraumaticbraininjurypatients