Cargando…

Two-way adjustable double-knots intrascleral fixation and single sclerotomy looping technique: a novel minimal invasive adjustable intraocular lens fixation technique

BACKGROUND: IOL fixation without capsular support presents challenges for surgeons. Although innovative techniques were developed to address subluxated IOLs, adjustable IOL fixation methods are seldom reported. We introduce a novel two-way adjustable double-knots intrascleral fixation combined with...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Lulu, Wang, Zaowen, Sun, Lu, Tang, Yongxiang, Sui, Wenda, Bian, Ailing, Zhang, Xia, Zhong, Yong, Zhang, Shunhua
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10668428/
https://www.ncbi.nlm.nih.gov/pubmed/37996816
http://dx.doi.org/10.1186/s12886-023-03235-2
_version_ 1785149128759574528
author Chen, Lulu
Wang, Zaowen
Sun, Lu
Tang, Yongxiang
Sui, Wenda
Bian, Ailing
Zhang, Xia
Zhong, Yong
Zhang, Shunhua
author_facet Chen, Lulu
Wang, Zaowen
Sun, Lu
Tang, Yongxiang
Sui, Wenda
Bian, Ailing
Zhang, Xia
Zhong, Yong
Zhang, Shunhua
author_sort Chen, Lulu
collection PubMed
description BACKGROUND: IOL fixation without capsular support presents challenges for surgeons. Although innovative techniques were developed to address subluxated IOLs, adjustable IOL fixation methods are seldom reported. We introduce a novel two-way adjustable double-knots intrascleral fixation combined with single sclerotomy looping technique for fixing intraocular lenses (IOL) or IOL-capsular bags. METHODS: A bent 30-gauge needle threaded with 8 − 0 polypropylene was introduced into the eye. A gripping forceps assisted the haptic looping. Two overhand knots were made with 8 − 0 polypropylene thread. The knots were incarcerated into a scleral tunnel made by a 30-gauge needle, with two ends of the thread left at each side of the tunnel. The IOL was adjusted to the premium position with adequate tension by pulling either end of the threads. The study included 19 eyes with aphakia, subluxated IOL-capsular bags, or subluxated crystalline lenses. The mean followed up period was 18.9 ± 7.1 months with evaluations of uncorrected visual acuity (UCVA), intraocular pressure, slit-lamp examination, and swept-source optical coherence tomography of the anterior segment. RESULTS: UCVA increased from 1.28 ± 0.74 at baseline to 0.44 ± 0.51 (logMAR) at final visit (P < 0.001). All IOLs were fixed well-centered. The mean IOL tilt was 3.5°±1.1°. Postoperative complications included transient IOP elevation (15.8%), hypotony (10.5%), and cystoid edema (5.3%) which resolved within 4 weeks. CONCLUSIONS: We presented a novel adjustable technique for IOL fixation, which stabilize IOLs by using an intrascleral double-knots structure. This technique minimized surgical manipulations by using a single sclerotomy looping technique without large conjunctival dissection and scleral flap creation. The technique offers a reliable and optimal IOL positioning and improved visual outcomes in patients undergoing scleral fixed IOL implantation.
format Online
Article
Text
id pubmed-10668428
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-106684282023-11-23 Two-way adjustable double-knots intrascleral fixation and single sclerotomy looping technique: a novel minimal invasive adjustable intraocular lens fixation technique Chen, Lulu Wang, Zaowen Sun, Lu Tang, Yongxiang Sui, Wenda Bian, Ailing Zhang, Xia Zhong, Yong Zhang, Shunhua BMC Ophthalmol Research BACKGROUND: IOL fixation without capsular support presents challenges for surgeons. Although innovative techniques were developed to address subluxated IOLs, adjustable IOL fixation methods are seldom reported. We introduce a novel two-way adjustable double-knots intrascleral fixation combined with single sclerotomy looping technique for fixing intraocular lenses (IOL) or IOL-capsular bags. METHODS: A bent 30-gauge needle threaded with 8 − 0 polypropylene was introduced into the eye. A gripping forceps assisted the haptic looping. Two overhand knots were made with 8 − 0 polypropylene thread. The knots were incarcerated into a scleral tunnel made by a 30-gauge needle, with two ends of the thread left at each side of the tunnel. The IOL was adjusted to the premium position with adequate tension by pulling either end of the threads. The study included 19 eyes with aphakia, subluxated IOL-capsular bags, or subluxated crystalline lenses. The mean followed up period was 18.9 ± 7.1 months with evaluations of uncorrected visual acuity (UCVA), intraocular pressure, slit-lamp examination, and swept-source optical coherence tomography of the anterior segment. RESULTS: UCVA increased from 1.28 ± 0.74 at baseline to 0.44 ± 0.51 (logMAR) at final visit (P < 0.001). All IOLs were fixed well-centered. The mean IOL tilt was 3.5°±1.1°. Postoperative complications included transient IOP elevation (15.8%), hypotony (10.5%), and cystoid edema (5.3%) which resolved within 4 weeks. CONCLUSIONS: We presented a novel adjustable technique for IOL fixation, which stabilize IOLs by using an intrascleral double-knots structure. This technique minimized surgical manipulations by using a single sclerotomy looping technique without large conjunctival dissection and scleral flap creation. The technique offers a reliable and optimal IOL positioning and improved visual outcomes in patients undergoing scleral fixed IOL implantation. BioMed Central 2023-11-23 /pmc/articles/PMC10668428/ /pubmed/37996816 http://dx.doi.org/10.1186/s12886-023-03235-2 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Chen, Lulu
Wang, Zaowen
Sun, Lu
Tang, Yongxiang
Sui, Wenda
Bian, Ailing
Zhang, Xia
Zhong, Yong
Zhang, Shunhua
Two-way adjustable double-knots intrascleral fixation and single sclerotomy looping technique: a novel minimal invasive adjustable intraocular lens fixation technique
title Two-way adjustable double-knots intrascleral fixation and single sclerotomy looping technique: a novel minimal invasive adjustable intraocular lens fixation technique
title_full Two-way adjustable double-knots intrascleral fixation and single sclerotomy looping technique: a novel minimal invasive adjustable intraocular lens fixation technique
title_fullStr Two-way adjustable double-knots intrascleral fixation and single sclerotomy looping technique: a novel minimal invasive adjustable intraocular lens fixation technique
title_full_unstemmed Two-way adjustable double-knots intrascleral fixation and single sclerotomy looping technique: a novel minimal invasive adjustable intraocular lens fixation technique
title_short Two-way adjustable double-knots intrascleral fixation and single sclerotomy looping technique: a novel minimal invasive adjustable intraocular lens fixation technique
title_sort two-way adjustable double-knots intrascleral fixation and single sclerotomy looping technique: a novel minimal invasive adjustable intraocular lens fixation technique
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10668428/
https://www.ncbi.nlm.nih.gov/pubmed/37996816
http://dx.doi.org/10.1186/s12886-023-03235-2
work_keys_str_mv AT chenlulu twowayadjustabledoubleknotsintrascleralfixationandsinglesclerotomyloopingtechniqueanovelminimalinvasiveadjustableintraocularlensfixationtechnique
AT wangzaowen twowayadjustabledoubleknotsintrascleralfixationandsinglesclerotomyloopingtechniqueanovelminimalinvasiveadjustableintraocularlensfixationtechnique
AT sunlu twowayadjustabledoubleknotsintrascleralfixationandsinglesclerotomyloopingtechniqueanovelminimalinvasiveadjustableintraocularlensfixationtechnique
AT tangyongxiang twowayadjustabledoubleknotsintrascleralfixationandsinglesclerotomyloopingtechniqueanovelminimalinvasiveadjustableintraocularlensfixationtechnique
AT suiwenda twowayadjustabledoubleknotsintrascleralfixationandsinglesclerotomyloopingtechniqueanovelminimalinvasiveadjustableintraocularlensfixationtechnique
AT bianailing twowayadjustabledoubleknotsintrascleralfixationandsinglesclerotomyloopingtechniqueanovelminimalinvasiveadjustableintraocularlensfixationtechnique
AT zhangxia twowayadjustabledoubleknotsintrascleralfixationandsinglesclerotomyloopingtechniqueanovelminimalinvasiveadjustableintraocularlensfixationtechnique
AT zhongyong twowayadjustabledoubleknotsintrascleralfixationandsinglesclerotomyloopingtechniqueanovelminimalinvasiveadjustableintraocularlensfixationtechnique
AT zhangshunhua twowayadjustabledoubleknotsintrascleralfixationandsinglesclerotomyloopingtechniqueanovelminimalinvasiveadjustableintraocularlensfixationtechnique