Cargando…

Association of Hand Grip Strength with Ultrasound-derived Forearm Muscle Thickness and Echo Intensity in Young Indian Adults

BACKGROUND: Muscle thickness (MT) quantification, which reflects the muscle function, can be measured using ultrasonography. Echo intensity (EI) quantified from the ultrasonography-derived skeletal muscle images reflects muscle quality. This study aimed to analyze the associations between handgrip s...

Descripción completa

Detalles Bibliográficos
Autores principales: Aruna, R., Sivarajan, Armel Arputha, Madhumitha, Meenakshi, Vasanth, C. J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10668901/
https://www.ncbi.nlm.nih.gov/pubmed/38025016
http://dx.doi.org/10.4103/jmu.jmu_28_22
_version_ 1785139572411203584
author Aruna, R.
Sivarajan, Armel Arputha
Madhumitha, Meenakshi
Vasanth, C. J.
author_facet Aruna, R.
Sivarajan, Armel Arputha
Madhumitha, Meenakshi
Vasanth, C. J.
author_sort Aruna, R.
collection PubMed
description BACKGROUND: Muscle thickness (MT) quantification, which reflects the muscle function, can be measured using ultrasonography. Echo intensity (EI) quantified from the ultrasonography-derived skeletal muscle images reflects muscle quality. This study aimed to analyze the associations between handgrip strength, ultrasound-measured forearm MT, and EI in healthy young adults. METHODS: Sixty healthy volunteers between the ages of 18 and 25 years participated in the study. Brightness mode ultrasonography (USG) was done to measure forearm radial and ulna MT. The EI was measured from an ultrasound image as a mean pixel value using a histogram in Adobe Photoshop. Individuals were tested for forearm handgrip strength using hand dynamometry. RESULTS: Males had higher forearm MT and handgrip strength compared to females. Handgrip strength had a significant positive correlation with forearm radius, ulna MT (r = 0.726, 0.757 and P < 0.01), and forearm circumference (r = 0.529 and P < 0.01) and a negatively correlation with subcutaneous fat thickness (r = −0.496 and P < 0.01) and EI (r = −0.618 and P < 0.01). Linear regression showed a significant correlation between MT, circumference, and EI with handgrip strength (r = 0.825 and P < 0.001). After adjustment for the other two parameters, the forearm MT correlated positively and EI negatively with handgrip strength. CONCLUSION: USG can be more easily used than other imaging methods in research and clinical setting as it is nonhazardous, less expensive, versatile, and provides results faster. Thus, USG measurements in skeletal muscle are useful for measuring MT and subcutaneous fat thickness. EI measurement can be a convenient and noninvasive method for assessing muscle quality.
format Online
Article
Text
id pubmed-10668901
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-106689012022-10-07 Association of Hand Grip Strength with Ultrasound-derived Forearm Muscle Thickness and Echo Intensity in Young Indian Adults Aruna, R. Sivarajan, Armel Arputha Madhumitha, Meenakshi Vasanth, C. J. J Med Ultrasound Original Article BACKGROUND: Muscle thickness (MT) quantification, which reflects the muscle function, can be measured using ultrasonography. Echo intensity (EI) quantified from the ultrasonography-derived skeletal muscle images reflects muscle quality. This study aimed to analyze the associations between handgrip strength, ultrasound-measured forearm MT, and EI in healthy young adults. METHODS: Sixty healthy volunteers between the ages of 18 and 25 years participated in the study. Brightness mode ultrasonography (USG) was done to measure forearm radial and ulna MT. The EI was measured from an ultrasound image as a mean pixel value using a histogram in Adobe Photoshop. Individuals were tested for forearm handgrip strength using hand dynamometry. RESULTS: Males had higher forearm MT and handgrip strength compared to females. Handgrip strength had a significant positive correlation with forearm radius, ulna MT (r = 0.726, 0.757 and P < 0.01), and forearm circumference (r = 0.529 and P < 0.01) and a negatively correlation with subcutaneous fat thickness (r = −0.496 and P < 0.01) and EI (r = −0.618 and P < 0.01). Linear regression showed a significant correlation between MT, circumference, and EI with handgrip strength (r = 0.825 and P < 0.001). After adjustment for the other two parameters, the forearm MT correlated positively and EI negatively with handgrip strength. CONCLUSION: USG can be more easily used than other imaging methods in research and clinical setting as it is nonhazardous, less expensive, versatile, and provides results faster. Thus, USG measurements in skeletal muscle are useful for measuring MT and subcutaneous fat thickness. EI measurement can be a convenient and noninvasive method for assessing muscle quality. Wolters Kluwer - Medknow 2022-10-07 /pmc/articles/PMC10668901/ /pubmed/38025016 http://dx.doi.org/10.4103/jmu.jmu_28_22 Text en Copyright: © 2022 Journal of Medical Ultrasound https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Aruna, R.
Sivarajan, Armel Arputha
Madhumitha, Meenakshi
Vasanth, C. J.
Association of Hand Grip Strength with Ultrasound-derived Forearm Muscle Thickness and Echo Intensity in Young Indian Adults
title Association of Hand Grip Strength with Ultrasound-derived Forearm Muscle Thickness and Echo Intensity in Young Indian Adults
title_full Association of Hand Grip Strength with Ultrasound-derived Forearm Muscle Thickness and Echo Intensity in Young Indian Adults
title_fullStr Association of Hand Grip Strength with Ultrasound-derived Forearm Muscle Thickness and Echo Intensity in Young Indian Adults
title_full_unstemmed Association of Hand Grip Strength with Ultrasound-derived Forearm Muscle Thickness and Echo Intensity in Young Indian Adults
title_short Association of Hand Grip Strength with Ultrasound-derived Forearm Muscle Thickness and Echo Intensity in Young Indian Adults
title_sort association of hand grip strength with ultrasound-derived forearm muscle thickness and echo intensity in young indian adults
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10668901/
https://www.ncbi.nlm.nih.gov/pubmed/38025016
http://dx.doi.org/10.4103/jmu.jmu_28_22
work_keys_str_mv AT arunar associationofhandgripstrengthwithultrasoundderivedforearmmusclethicknessandechointensityinyoungindianadults
AT sivarajanarmelarputha associationofhandgripstrengthwithultrasoundderivedforearmmusclethicknessandechointensityinyoungindianadults
AT madhumithameenakshi associationofhandgripstrengthwithultrasoundderivedforearmmusclethicknessandechointensityinyoungindianadults
AT vasanthcj associationofhandgripstrengthwithultrasoundderivedforearmmusclethicknessandechointensityinyoungindianadults