Cargando…

Long-Term Clinical Outcomes of Ahmed Valve Implantation in Aniridic Glaucoma

Background: This study assessed the efficacy and safety of Ahmed valve implantation in patients with aniridic glaucoma for three consecutive years. Methods: Six adult patients (seven eyes) with Ahmed valve (AV) implants for aniridic glaucoma were enrolled in the study. The primary outcome measures w...

Descripción completa

Detalles Bibliográficos
Autores principales: Bolek, Bartłomiej, Wylęgała, Edward, Tarnawska, Dorota
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10669343/
https://www.ncbi.nlm.nih.gov/pubmed/38001995
http://dx.doi.org/10.3390/biomedicines11112996
Descripción
Sumario:Background: This study assessed the efficacy and safety of Ahmed valve implantation in patients with aniridic glaucoma for three consecutive years. Methods: Six adult patients (seven eyes) with Ahmed valve (AV) implants for aniridic glaucoma were enrolled in the study. The primary outcome measures were intraocular pressure reduction, glaucoma medication use, success rates, and visual acuity after AV implantation. A 30% reduction in IOP from baseline without the need for re-intervention was considered an effective treatment. The cessation of antiglaucoma medications was defined as complete success. Intraoperative and postoperative complications were included as secondary outcome measures. Measurements were performed preoperatively, at the first week, and 1, 3, 6, 12, 18, 24, 30, and 36 months postoperatively. Results: A total of seven eyes (6 patients) were evaluated 36 months after AV implantation. The mean ± SD values of IOP preoperatively at 1 day, 1 week, and 1, 3, 6, 12, 18, 24, 30, and 36 months postoperatively were 30.4 ± 4.0 mmHg, 14.6 ± 4.6 mmHg, 16.1 ± 4.6 mmHg, 20.7 ± 7.0 mmHg, 14.5 ± 2.7 mmHg, 16.5 ± 5.9 mmHg, 16.2 ± 4.0 mmHg, 16.3 ± 4.3 mmHg, 17.2 ± 10.1 mmHg, 17.6 ± 6.9 mmHg, and 18.2 ± 5.5 mmHg, respectively. At the last follow up, the mean IOP was reduced by 40.2%. The qualified success rate was 85.7%. One patient (one eye) at the last follow-up visit did not require antiglaucoma medications, resulting in a complete success rate of 14.3%. Intra- and postoperative mild or moderate subconjunctival bleeding was observed in all the patients. No other major/minor intraoperative or postoperative complications were noted. Conclusions: In long-term follow up, the AV implantation procedure is well-tolerated and relatively safe for reducing IOP in adult aniridia patients with glaucoma. These results should be validated through studies involving a larger patient cohort.