Fabrication of an Azithromycin Sensor

Azithromycin (AZY) is a well-known top-prioritized antibiotic and is used by humans in strong concentrations. However, the side effects of the AZY antibiotic may cause some serious and significant damage to humans and the environment. Thus, there is a need to develop effective and sensitive sensors...

Descripción completa

Detalles Bibliográficos
Autores principales: Niyitanga, Theophile, Khan, Mohd Quasim, Ahmad, Khursheed, Khan, Rais Ahmad
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10669414/
https://www.ncbi.nlm.nih.gov/pubmed/37998161
http://dx.doi.org/10.3390/bios13110986
_version_ 1785149230257537024
author Niyitanga, Theophile
Khan, Mohd Quasim
Ahmad, Khursheed
Khan, Rais Ahmad
author_facet Niyitanga, Theophile
Khan, Mohd Quasim
Ahmad, Khursheed
Khan, Rais Ahmad
author_sort Niyitanga, Theophile
collection PubMed
description Azithromycin (AZY) is a well-known top-prioritized antibiotic and is used by humans in strong concentrations. However, the side effects of the AZY antibiotic may cause some serious and significant damage to humans and the environment. Thus, there is a need to develop effective and sensitive sensors to monitor accurate concentrations of AZY. In the last decade, electrochemistry-based sensors have received enormous attention from the scientific community because of their high sensitivity, selectivity, cost-effectiveness, fast response, rapid detection response, simple fabrication, and working principle. It is important to mention that electrochemical sensors rely on the properties of electrode modifiers. Hence, the selection of electrode materials is of great significance when designing and developing efficient and robust electrochemical sensors. In this study, we fabricated an AZY sensor by utilizing a molybdenum disulfide/titanium aluminum carbide (MoS(2)@Ti(3)AlC(2)) composite as the electrode material. The MoS(2)@Ti(3)AlC(2) composite was synthesized via a simple sonication process. The synthesized MoS(2)@Ti(3)AlC(2) composite was characterized using a powder X-ray diffraction (XRD) method to examine the phase purity and formation of the MoS(2)@Ti(3)AlC(2) composite. Scanning electron microscopy (SEM) was used to study the surface morphological features of the prepared MoS(2)@Ti(3)AlC(2) composite, whereas energy dispersive X-ray spectroscopy (EDAX) was adopted to determine the elemental composition of the prepared MoS(2)@Ti(3)AlC(2) composite. The glassy carbon (GC) electrode was modified with the prepared MoS(2)@Ti(3)AlC(2) composite and applied as the AZY sensor. The sensing performance of the MoS(2)@Ti(3)AlC(2) composite-modified GC electrode was studied using linear sweep voltammetry. The sensor demonstrated excellent performance when determining AZY and showed a good detection limit of 0.009 µM with a sensitivity of 6.77 µA/µM.cm(2).
format Online
Article
Text
id pubmed-10669414
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-106694142023-11-16 Fabrication of an Azithromycin Sensor Niyitanga, Theophile Khan, Mohd Quasim Ahmad, Khursheed Khan, Rais Ahmad Biosensors (Basel) Article Azithromycin (AZY) is a well-known top-prioritized antibiotic and is used by humans in strong concentrations. However, the side effects of the AZY antibiotic may cause some serious and significant damage to humans and the environment. Thus, there is a need to develop effective and sensitive sensors to monitor accurate concentrations of AZY. In the last decade, electrochemistry-based sensors have received enormous attention from the scientific community because of their high sensitivity, selectivity, cost-effectiveness, fast response, rapid detection response, simple fabrication, and working principle. It is important to mention that electrochemical sensors rely on the properties of electrode modifiers. Hence, the selection of electrode materials is of great significance when designing and developing efficient and robust electrochemical sensors. In this study, we fabricated an AZY sensor by utilizing a molybdenum disulfide/titanium aluminum carbide (MoS(2)@Ti(3)AlC(2)) composite as the electrode material. The MoS(2)@Ti(3)AlC(2) composite was synthesized via a simple sonication process. The synthesized MoS(2)@Ti(3)AlC(2) composite was characterized using a powder X-ray diffraction (XRD) method to examine the phase purity and formation of the MoS(2)@Ti(3)AlC(2) composite. Scanning electron microscopy (SEM) was used to study the surface morphological features of the prepared MoS(2)@Ti(3)AlC(2) composite, whereas energy dispersive X-ray spectroscopy (EDAX) was adopted to determine the elemental composition of the prepared MoS(2)@Ti(3)AlC(2) composite. The glassy carbon (GC) electrode was modified with the prepared MoS(2)@Ti(3)AlC(2) composite and applied as the AZY sensor. The sensing performance of the MoS(2)@Ti(3)AlC(2) composite-modified GC electrode was studied using linear sweep voltammetry. The sensor demonstrated excellent performance when determining AZY and showed a good detection limit of 0.009 µM with a sensitivity of 6.77 µA/µM.cm(2). MDPI 2023-11-16 /pmc/articles/PMC10669414/ /pubmed/37998161 http://dx.doi.org/10.3390/bios13110986 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Niyitanga, Theophile
Khan, Mohd Quasim
Ahmad, Khursheed
Khan, Rais Ahmad
Fabrication of an Azithromycin Sensor
title Fabrication of an Azithromycin Sensor
title_full Fabrication of an Azithromycin Sensor
title_fullStr Fabrication of an Azithromycin Sensor
title_full_unstemmed Fabrication of an Azithromycin Sensor
title_short Fabrication of an Azithromycin Sensor
title_sort fabrication of an azithromycin sensor
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10669414/
https://www.ncbi.nlm.nih.gov/pubmed/37998161
http://dx.doi.org/10.3390/bios13110986
work_keys_str_mv AT niyitangatheophile fabricationofanazithromycinsensor
AT khanmohdquasim fabricationofanazithromycinsensor
AT ahmadkhursheed fabricationofanazithromycinsensor
AT khanraisahmad fabricationofanazithromycinsensor