Dosimetric impact of applicator displacement on three-dimensional image-guided high-dose-rate brachytherapy treatments for cervical cancer

PURPOSE: To determine the dosimetric impact of brachytherapy applicator displacement during intracavitary (IC) and combined intracavitary/interstitial (IC/IS) high-dose-rate brachytherapy in the treatment of cervical cancer. MATERIAL AND METHODS: Data from 27 consecutively treated patients undergoin...

Descripción completa

Detalles Bibliográficos
Autores principales: Jayarathna, Sandun, Hoang, Matthew, Badkul, Rajeev, Hoover, Andrew
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10669918/
https://www.ncbi.nlm.nih.gov/pubmed/38026073
http://dx.doi.org/10.5114/jcb.2023.132697
_version_ 1785139804356214784
author Jayarathna, Sandun
Hoang, Matthew
Badkul, Rajeev
Hoover, Andrew
author_facet Jayarathna, Sandun
Hoang, Matthew
Badkul, Rajeev
Hoover, Andrew
author_sort Jayarathna, Sandun
collection PubMed
description PURPOSE: To determine the dosimetric impact of brachytherapy applicator displacement during intracavitary (IC) and combined intracavitary/interstitial (IC/IS) high-dose-rate brachytherapy in the treatment of cervical cancer. MATERIAL AND METHODS: Data from 27 consecutively treated patients undergoing IC or IC/IS high-dose-rate brachytherapy with tandem and ovoid-based applicators at a single academic medical center were analyzed. Virtual applicator displacements (a single shift of whole applicator with tandem/ovoid/associated needles) of 0 (clinical position), 2, 5, 7, and 10 mm in the inferior direction were modeled on treatment planning CT or MRI scans, with maintaining the same dwell times. Radiation dose to target volumes (D(90) of high-risk clinical target volume) and organs at risk (OARs) (D(0.1cc), D(1cc), and D(2cc) of bladder, rectum, and sigmoid) were calculated for each virtual applicator shift, and significance of displacements was assessed using general linear model and Kruskal-Wallis test. RESULTS: Mean dose to high-risk clinical target volume (HR-CTV) D(90) was 95.7%, 88.9%, 84.6%, and 77.1% of the prescribed dose in clinical position with displacements of 2, 5, 7, and 10 mm, respectively. Rectal D(2cc) significantly increased by 28% and 44% at displacement of 7 mm and 10 mm, respectively. IC/IS cases showed relatively greater dosimetric differences than IC cases, with HR-CTV D(90) doses of 94.4%, 85.8%, 80.4%, and 72.4% at virtual displacements of 2, 5, 7, and 10 mm, respectively. CONCLUSIONS: Applicator displacements of 5 mm or greater result in statistically significant and clinically meaningful decreases in radiation dose to HR-CTV during 3-dimensional high-dose-rate brachytherapy treatment planning, with corresponding increase in radiation dose to the rectum. IC/IS applicator displacements lead to relatively greater differences than those of IC applicators.
format Online
Article
Text
id pubmed-10669918
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Termedia Publishing House
record_format MEDLINE/PubMed
spelling pubmed-106699182023-10-01 Dosimetric impact of applicator displacement on three-dimensional image-guided high-dose-rate brachytherapy treatments for cervical cancer Jayarathna, Sandun Hoang, Matthew Badkul, Rajeev Hoover, Andrew J Contemp Brachytherapy Original Paper PURPOSE: To determine the dosimetric impact of brachytherapy applicator displacement during intracavitary (IC) and combined intracavitary/interstitial (IC/IS) high-dose-rate brachytherapy in the treatment of cervical cancer. MATERIAL AND METHODS: Data from 27 consecutively treated patients undergoing IC or IC/IS high-dose-rate brachytherapy with tandem and ovoid-based applicators at a single academic medical center were analyzed. Virtual applicator displacements (a single shift of whole applicator with tandem/ovoid/associated needles) of 0 (clinical position), 2, 5, 7, and 10 mm in the inferior direction were modeled on treatment planning CT or MRI scans, with maintaining the same dwell times. Radiation dose to target volumes (D(90) of high-risk clinical target volume) and organs at risk (OARs) (D(0.1cc), D(1cc), and D(2cc) of bladder, rectum, and sigmoid) were calculated for each virtual applicator shift, and significance of displacements was assessed using general linear model and Kruskal-Wallis test. RESULTS: Mean dose to high-risk clinical target volume (HR-CTV) D(90) was 95.7%, 88.9%, 84.6%, and 77.1% of the prescribed dose in clinical position with displacements of 2, 5, 7, and 10 mm, respectively. Rectal D(2cc) significantly increased by 28% and 44% at displacement of 7 mm and 10 mm, respectively. IC/IS cases showed relatively greater dosimetric differences than IC cases, with HR-CTV D(90) doses of 94.4%, 85.8%, 80.4%, and 72.4% at virtual displacements of 2, 5, 7, and 10 mm, respectively. CONCLUSIONS: Applicator displacements of 5 mm or greater result in statistically significant and clinically meaningful decreases in radiation dose to HR-CTV during 3-dimensional high-dose-rate brachytherapy treatment planning, with corresponding increase in radiation dose to the rectum. IC/IS applicator displacements lead to relatively greater differences than those of IC applicators. Termedia Publishing House 2023-10-31 2023-10 /pmc/articles/PMC10669918/ /pubmed/38026073 http://dx.doi.org/10.5114/jcb.2023.132697 Text en Copyright © 2023 Termedia https://creativecommons.org/licenses/by-nc-sa/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0). License (http://creativecommons.org/licenses/by-nc-sa/4.0/ (https://creativecommons.org/licenses/by-nc-sa/4.0/) )
spellingShingle Original Paper
Jayarathna, Sandun
Hoang, Matthew
Badkul, Rajeev
Hoover, Andrew
Dosimetric impact of applicator displacement on three-dimensional image-guided high-dose-rate brachytherapy treatments for cervical cancer
title Dosimetric impact of applicator displacement on three-dimensional image-guided high-dose-rate brachytherapy treatments for cervical cancer
title_full Dosimetric impact of applicator displacement on three-dimensional image-guided high-dose-rate brachytherapy treatments for cervical cancer
title_fullStr Dosimetric impact of applicator displacement on three-dimensional image-guided high-dose-rate brachytherapy treatments for cervical cancer
title_full_unstemmed Dosimetric impact of applicator displacement on three-dimensional image-guided high-dose-rate brachytherapy treatments for cervical cancer
title_short Dosimetric impact of applicator displacement on three-dimensional image-guided high-dose-rate brachytherapy treatments for cervical cancer
title_sort dosimetric impact of applicator displacement on three-dimensional image-guided high-dose-rate brachytherapy treatments for cervical cancer
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10669918/
https://www.ncbi.nlm.nih.gov/pubmed/38026073
http://dx.doi.org/10.5114/jcb.2023.132697
work_keys_str_mv AT jayarathnasandun dosimetricimpactofapplicatordisplacementonthreedimensionalimageguidedhighdoseratebrachytherapytreatmentsforcervicalcancer
AT hoangmatthew dosimetricimpactofapplicatordisplacementonthreedimensionalimageguidedhighdoseratebrachytherapytreatmentsforcervicalcancer
AT badkulrajeev dosimetricimpactofapplicatordisplacementonthreedimensionalimageguidedhighdoseratebrachytherapytreatmentsforcervicalcancer
AT hooverandrew dosimetricimpactofapplicatordisplacementonthreedimensionalimageguidedhighdoseratebrachytherapytreatmentsforcervicalcancer