Cargando…

Physical Image Quality Metrics for the Characterization of X-ray Systems Used in Fluoroscopy-Guided Pediatric Cardiac Interventional Procedures: A Systematic Review

Pediatric interventional cardiology procedures are essential in diagnosing and treating congenital heart disease in children; however, they raise concerns about potential radiation exposure. Managing radiation doses and assessing image quality in angiographs becomes imperative for safe and effective...

Descripción completa

Detalles Bibliográficos
Autores principales: Nocetti, Diego, Villalobos, Kathia, Wunderle, Kevin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10670102/
https://www.ncbi.nlm.nih.gov/pubmed/38002875
http://dx.doi.org/10.3390/children10111784
_version_ 1785139844856414208
author Nocetti, Diego
Villalobos, Kathia
Wunderle, Kevin
author_facet Nocetti, Diego
Villalobos, Kathia
Wunderle, Kevin
author_sort Nocetti, Diego
collection PubMed
description Pediatric interventional cardiology procedures are essential in diagnosing and treating congenital heart disease in children; however, they raise concerns about potential radiation exposure. Managing radiation doses and assessing image quality in angiographs becomes imperative for safe and effective interventions. This systematic review aims to comprehensively analyze the current understanding of physical image quality metrics relevant for characterizing X-ray systems used in fluoroscopy-guided pediatric cardiac interventional procedures, considering the main factors reported in the literature that influence this outcome. A search in Scopus and Web of Science, using relevant keywords and inclusion/exclusion criteria, yielded 14 relevant articles published between 2000 and 2022. The physical image quality metrics reported were noise, signal-to-noise ratio, contrast, contrast-to-noise ratio, and high-contrast spatial resolution. Various factors influencing image quality were investigated, such as polymethyl methacrylate thickness (often used to simulate water equivalent tissue thickness), operation mode, anti-scatter grid presence, and tube voltage. Objective evaluations using these metrics ensured impartial assessments for main factors affecting image quality, improving the characterization of fluoroscopic X-ray systems, and aiding informed decision making to safeguard pediatric patients during procedures.
format Online
Article
Text
id pubmed-10670102
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-106701022023-11-05 Physical Image Quality Metrics for the Characterization of X-ray Systems Used in Fluoroscopy-Guided Pediatric Cardiac Interventional Procedures: A Systematic Review Nocetti, Diego Villalobos, Kathia Wunderle, Kevin Children (Basel) Review Pediatric interventional cardiology procedures are essential in diagnosing and treating congenital heart disease in children; however, they raise concerns about potential radiation exposure. Managing radiation doses and assessing image quality in angiographs becomes imperative for safe and effective interventions. This systematic review aims to comprehensively analyze the current understanding of physical image quality metrics relevant for characterizing X-ray systems used in fluoroscopy-guided pediatric cardiac interventional procedures, considering the main factors reported in the literature that influence this outcome. A search in Scopus and Web of Science, using relevant keywords and inclusion/exclusion criteria, yielded 14 relevant articles published between 2000 and 2022. The physical image quality metrics reported were noise, signal-to-noise ratio, contrast, contrast-to-noise ratio, and high-contrast spatial resolution. Various factors influencing image quality were investigated, such as polymethyl methacrylate thickness (often used to simulate water equivalent tissue thickness), operation mode, anti-scatter grid presence, and tube voltage. Objective evaluations using these metrics ensured impartial assessments for main factors affecting image quality, improving the characterization of fluoroscopic X-ray systems, and aiding informed decision making to safeguard pediatric patients during procedures. MDPI 2023-11-05 /pmc/articles/PMC10670102/ /pubmed/38002875 http://dx.doi.org/10.3390/children10111784 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Review
Nocetti, Diego
Villalobos, Kathia
Wunderle, Kevin
Physical Image Quality Metrics for the Characterization of X-ray Systems Used in Fluoroscopy-Guided Pediatric Cardiac Interventional Procedures: A Systematic Review
title Physical Image Quality Metrics for the Characterization of X-ray Systems Used in Fluoroscopy-Guided Pediatric Cardiac Interventional Procedures: A Systematic Review
title_full Physical Image Quality Metrics for the Characterization of X-ray Systems Used in Fluoroscopy-Guided Pediatric Cardiac Interventional Procedures: A Systematic Review
title_fullStr Physical Image Quality Metrics for the Characterization of X-ray Systems Used in Fluoroscopy-Guided Pediatric Cardiac Interventional Procedures: A Systematic Review
title_full_unstemmed Physical Image Quality Metrics for the Characterization of X-ray Systems Used in Fluoroscopy-Guided Pediatric Cardiac Interventional Procedures: A Systematic Review
title_short Physical Image Quality Metrics for the Characterization of X-ray Systems Used in Fluoroscopy-Guided Pediatric Cardiac Interventional Procedures: A Systematic Review
title_sort physical image quality metrics for the characterization of x-ray systems used in fluoroscopy-guided pediatric cardiac interventional procedures: a systematic review
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10670102/
https://www.ncbi.nlm.nih.gov/pubmed/38002875
http://dx.doi.org/10.3390/children10111784
work_keys_str_mv AT nocettidiego physicalimagequalitymetricsforthecharacterizationofxraysystemsusedinfluoroscopyguidedpediatriccardiacinterventionalproceduresasystematicreview
AT villaloboskathia physicalimagequalitymetricsforthecharacterizationofxraysystemsusedinfluoroscopyguidedpediatriccardiacinterventionalproceduresasystematicreview
AT wunderlekevin physicalimagequalitymetricsforthecharacterizationofxraysystemsusedinfluoroscopyguidedpediatriccardiacinterventionalproceduresasystematicreview