Cargando…

Integrated Performance Evaluation of Aerogel-Based Fibre-Enhanced Thermal Renders Applied on Building Walls

In this work, aerogel renders were enhanced with fibres for use in new building walls, emphasising a Mediterranean climate. The main novelty of the study relies on an integrated evaluation of the aerogel-based fibre-enhanced thermal renders from environmental, energy and economic approaches. Therefo...

Descripción completa

Detalles Bibliográficos
Autores principales: Pedroso, Marco, Silvestre, José Dinis, Gomes, Maria da Glória, Hawreen, Ahmed, Bersch, Jéssica D., Flores-Colen, Inês
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10671097/
https://www.ncbi.nlm.nih.gov/pubmed/37998988
http://dx.doi.org/10.3390/gels9110898
_version_ 1785149375939346432
author Pedroso, Marco
Silvestre, José Dinis
Gomes, Maria da Glória
Hawreen, Ahmed
Bersch, Jéssica D.
Flores-Colen, Inês
author_facet Pedroso, Marco
Silvestre, José Dinis
Gomes, Maria da Glória
Hawreen, Ahmed
Bersch, Jéssica D.
Flores-Colen, Inês
author_sort Pedroso, Marco
collection PubMed
description In this work, aerogel renders were enhanced with fibres for use in new building walls, emphasising a Mediterranean climate. The main novelty of the study relies on an integrated evaluation of the aerogel-based fibre-enhanced thermal renders from environmental, energy and economic approaches. Therefore, optimum insulation thicknesses, life cycle savings, payback periods, abiotic depletion potential from fossil fuels (ADP-ff) and global warming potential (GWP) impacts were quantified as a function of the energy consumption. The cost optimisation of aerogel-based renders enabled a reduction from 2477.4 to 1021.7 EUR∙m(−3) for the reference formulation, and the sisal-optimised render led to the best-integrated performance. A higher DD* (degree-days equivalent) led to higher optimum thicknesses (the Azores required 0.02 m and 0.01 m and Bragança 0.06 m and 0.03 m for cost-optimised and non-optimised thermal renders with sisal fibre, respectively). The optimum thickness related to the ADP-ff and GWP impacts was higher, 0.04 m for the Azores and 0.09 m for Bragança. A steeper decrease in the annual energy consumption occurred for thermal renders up to 0.02 m in the Azores and 0.04 m in Bragança. Aerogel-based fibre-enhanced thermal renders had benefits, mainly from 600 DD* onwards.
format Online
Article
Text
id pubmed-10671097
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-106710972023-11-13 Integrated Performance Evaluation of Aerogel-Based Fibre-Enhanced Thermal Renders Applied on Building Walls Pedroso, Marco Silvestre, José Dinis Gomes, Maria da Glória Hawreen, Ahmed Bersch, Jéssica D. Flores-Colen, Inês Gels Article In this work, aerogel renders were enhanced with fibres for use in new building walls, emphasising a Mediterranean climate. The main novelty of the study relies on an integrated evaluation of the aerogel-based fibre-enhanced thermal renders from environmental, energy and economic approaches. Therefore, optimum insulation thicknesses, life cycle savings, payback periods, abiotic depletion potential from fossil fuels (ADP-ff) and global warming potential (GWP) impacts were quantified as a function of the energy consumption. The cost optimisation of aerogel-based renders enabled a reduction from 2477.4 to 1021.7 EUR∙m(−3) for the reference formulation, and the sisal-optimised render led to the best-integrated performance. A higher DD* (degree-days equivalent) led to higher optimum thicknesses (the Azores required 0.02 m and 0.01 m and Bragança 0.06 m and 0.03 m for cost-optimised and non-optimised thermal renders with sisal fibre, respectively). The optimum thickness related to the ADP-ff and GWP impacts was higher, 0.04 m for the Azores and 0.09 m for Bragança. A steeper decrease in the annual energy consumption occurred for thermal renders up to 0.02 m in the Azores and 0.04 m in Bragança. Aerogel-based fibre-enhanced thermal renders had benefits, mainly from 600 DD* onwards. MDPI 2023-11-13 /pmc/articles/PMC10671097/ /pubmed/37998988 http://dx.doi.org/10.3390/gels9110898 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Pedroso, Marco
Silvestre, José Dinis
Gomes, Maria da Glória
Hawreen, Ahmed
Bersch, Jéssica D.
Flores-Colen, Inês
Integrated Performance Evaluation of Aerogel-Based Fibre-Enhanced Thermal Renders Applied on Building Walls
title Integrated Performance Evaluation of Aerogel-Based Fibre-Enhanced Thermal Renders Applied on Building Walls
title_full Integrated Performance Evaluation of Aerogel-Based Fibre-Enhanced Thermal Renders Applied on Building Walls
title_fullStr Integrated Performance Evaluation of Aerogel-Based Fibre-Enhanced Thermal Renders Applied on Building Walls
title_full_unstemmed Integrated Performance Evaluation of Aerogel-Based Fibre-Enhanced Thermal Renders Applied on Building Walls
title_short Integrated Performance Evaluation of Aerogel-Based Fibre-Enhanced Thermal Renders Applied on Building Walls
title_sort integrated performance evaluation of aerogel-based fibre-enhanced thermal renders applied on building walls
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10671097/
https://www.ncbi.nlm.nih.gov/pubmed/37998988
http://dx.doi.org/10.3390/gels9110898
work_keys_str_mv AT pedrosomarco integratedperformanceevaluationofaerogelbasedfibreenhancedthermalrendersappliedonbuildingwalls
AT silvestrejosedinis integratedperformanceevaluationofaerogelbasedfibreenhancedthermalrendersappliedonbuildingwalls
AT gomesmariadagloria integratedperformanceevaluationofaerogelbasedfibreenhancedthermalrendersappliedonbuildingwalls
AT hawreenahmed integratedperformanceevaluationofaerogelbasedfibreenhancedthermalrendersappliedonbuildingwalls
AT berschjessicad integratedperformanceevaluationofaerogelbasedfibreenhancedthermalrendersappliedonbuildingwalls
AT florescolenines integratedperformanceevaluationofaerogelbasedfibreenhancedthermalrendersappliedonbuildingwalls