Cargando…

Morphological Comparison of Residual Ridge in Impression for Removable Partial Denture between Digital and Conventional Techniques: A Preliminary In-Vivo Study

Although digital impression using an intraoral scanner (IOS) has been applied for removable partial denture (RPD) fabrication, it is still unclear how the morphology of a residual ridge recorded by digital impression would differ from that recorded by conventional impression. This in vivo study inve...

Descripción completa

Detalles Bibliográficos
Autores principales: Ishioka, Yurika, Wada, Junichiro, Kim, Eung-Yeol, Sakamoto, Kazuki, Arai, Yuki, Murakami, Natsuko, Yamazaki, Toshiki, Takakusaki, Kensuke, Hayama, Hironari, Utsumi, Miona, Inukai, Shusuke, Wakabayashi, Noriyuki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10671937/
https://www.ncbi.nlm.nih.gov/pubmed/38002714
http://dx.doi.org/10.3390/jcm12227103
_version_ 1785149475525754880
author Ishioka, Yurika
Wada, Junichiro
Kim, Eung-Yeol
Sakamoto, Kazuki
Arai, Yuki
Murakami, Natsuko
Yamazaki, Toshiki
Takakusaki, Kensuke
Hayama, Hironari
Utsumi, Miona
Inukai, Shusuke
Wakabayashi, Noriyuki
author_facet Ishioka, Yurika
Wada, Junichiro
Kim, Eung-Yeol
Sakamoto, Kazuki
Arai, Yuki
Murakami, Natsuko
Yamazaki, Toshiki
Takakusaki, Kensuke
Hayama, Hironari
Utsumi, Miona
Inukai, Shusuke
Wakabayashi, Noriyuki
author_sort Ishioka, Yurika
collection PubMed
description Although digital impression using an intraoral scanner (IOS) has been applied for removable partial denture (RPD) fabrication, it is still unclear how the morphology of a residual ridge recorded by digital impression would differ from that recorded by conventional impression. This in vivo study investigated the morphological difference in the recorded residual ridge between digital and conventional impressions. Vertical and horizontal displacements (VD and HD) in residual ridges recorded by digital and conventional impressions were assessed in 22 participants (15 female; mean age 78.2 years) based on the morphology of the tissue surface of in-use RPD. Additionally, the mucosal thickness of the residual ridge was recorded using an ultrasound diagnostic device. VD and HD were compared using the Wilcoxon signed-rank test, and the correlation of mucosal thickness with VD and HD was analyzed using Spearman’s ρ. The VD of digital impression was significantly greater than that of a conventional impression (p = 0.031), while no significant difference was found in HD (p = 0.322). Meanwhile, the mucosal thickness showed no significant correlation with the recorded morphology of the residual ridge, regardless of the impression techniques. It was concluded that the digital impression would result in a greater displacement in the height of the residual ridge from the morphology of in-use RPD than the conventional impression.
format Online
Article
Text
id pubmed-10671937
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-106719372023-11-15 Morphological Comparison of Residual Ridge in Impression for Removable Partial Denture between Digital and Conventional Techniques: A Preliminary In-Vivo Study Ishioka, Yurika Wada, Junichiro Kim, Eung-Yeol Sakamoto, Kazuki Arai, Yuki Murakami, Natsuko Yamazaki, Toshiki Takakusaki, Kensuke Hayama, Hironari Utsumi, Miona Inukai, Shusuke Wakabayashi, Noriyuki J Clin Med Article Although digital impression using an intraoral scanner (IOS) has been applied for removable partial denture (RPD) fabrication, it is still unclear how the morphology of a residual ridge recorded by digital impression would differ from that recorded by conventional impression. This in vivo study investigated the morphological difference in the recorded residual ridge between digital and conventional impressions. Vertical and horizontal displacements (VD and HD) in residual ridges recorded by digital and conventional impressions were assessed in 22 participants (15 female; mean age 78.2 years) based on the morphology of the tissue surface of in-use RPD. Additionally, the mucosal thickness of the residual ridge was recorded using an ultrasound diagnostic device. VD and HD were compared using the Wilcoxon signed-rank test, and the correlation of mucosal thickness with VD and HD was analyzed using Spearman’s ρ. The VD of digital impression was significantly greater than that of a conventional impression (p = 0.031), while no significant difference was found in HD (p = 0.322). Meanwhile, the mucosal thickness showed no significant correlation with the recorded morphology of the residual ridge, regardless of the impression techniques. It was concluded that the digital impression would result in a greater displacement in the height of the residual ridge from the morphology of in-use RPD than the conventional impression. MDPI 2023-11-15 /pmc/articles/PMC10671937/ /pubmed/38002714 http://dx.doi.org/10.3390/jcm12227103 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ishioka, Yurika
Wada, Junichiro
Kim, Eung-Yeol
Sakamoto, Kazuki
Arai, Yuki
Murakami, Natsuko
Yamazaki, Toshiki
Takakusaki, Kensuke
Hayama, Hironari
Utsumi, Miona
Inukai, Shusuke
Wakabayashi, Noriyuki
Morphological Comparison of Residual Ridge in Impression for Removable Partial Denture between Digital and Conventional Techniques: A Preliminary In-Vivo Study
title Morphological Comparison of Residual Ridge in Impression for Removable Partial Denture between Digital and Conventional Techniques: A Preliminary In-Vivo Study
title_full Morphological Comparison of Residual Ridge in Impression for Removable Partial Denture between Digital and Conventional Techniques: A Preliminary In-Vivo Study
title_fullStr Morphological Comparison of Residual Ridge in Impression for Removable Partial Denture between Digital and Conventional Techniques: A Preliminary In-Vivo Study
title_full_unstemmed Morphological Comparison of Residual Ridge in Impression for Removable Partial Denture between Digital and Conventional Techniques: A Preliminary In-Vivo Study
title_short Morphological Comparison of Residual Ridge in Impression for Removable Partial Denture between Digital and Conventional Techniques: A Preliminary In-Vivo Study
title_sort morphological comparison of residual ridge in impression for removable partial denture between digital and conventional techniques: a preliminary in-vivo study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10671937/
https://www.ncbi.nlm.nih.gov/pubmed/38002714
http://dx.doi.org/10.3390/jcm12227103
work_keys_str_mv AT ishiokayurika morphologicalcomparisonofresidualridgeinimpressionforremovablepartialdenturebetweendigitalandconventionaltechniquesapreliminaryinvivostudy
AT wadajunichiro morphologicalcomparisonofresidualridgeinimpressionforremovablepartialdenturebetweendigitalandconventionaltechniquesapreliminaryinvivostudy
AT kimeungyeol morphologicalcomparisonofresidualridgeinimpressionforremovablepartialdenturebetweendigitalandconventionaltechniquesapreliminaryinvivostudy
AT sakamotokazuki morphologicalcomparisonofresidualridgeinimpressionforremovablepartialdenturebetweendigitalandconventionaltechniquesapreliminaryinvivostudy
AT araiyuki morphologicalcomparisonofresidualridgeinimpressionforremovablepartialdenturebetweendigitalandconventionaltechniquesapreliminaryinvivostudy
AT murakaminatsuko morphologicalcomparisonofresidualridgeinimpressionforremovablepartialdenturebetweendigitalandconventionaltechniquesapreliminaryinvivostudy
AT yamazakitoshiki morphologicalcomparisonofresidualridgeinimpressionforremovablepartialdenturebetweendigitalandconventionaltechniquesapreliminaryinvivostudy
AT takakusakikensuke morphologicalcomparisonofresidualridgeinimpressionforremovablepartialdenturebetweendigitalandconventionaltechniquesapreliminaryinvivostudy
AT hayamahironari morphologicalcomparisonofresidualridgeinimpressionforremovablepartialdenturebetweendigitalandconventionaltechniquesapreliminaryinvivostudy
AT utsumimiona morphologicalcomparisonofresidualridgeinimpressionforremovablepartialdenturebetweendigitalandconventionaltechniquesapreliminaryinvivostudy
AT inukaishusuke morphologicalcomparisonofresidualridgeinimpressionforremovablepartialdenturebetweendigitalandconventionaltechniquesapreliminaryinvivostudy
AT wakabayashinoriyuki morphologicalcomparisonofresidualridgeinimpressionforremovablepartialdenturebetweendigitalandconventionaltechniquesapreliminaryinvivostudy