Cargando…

Scheimpflug Corneal Densitometry Patterns at the Graft–Host Interface in DMEK and DSAEK: A 12-Month Longitudinal Comparative Study

Background: To compare corneal densitometry (CD) patterns at the graft–host interface between Descemet Membrane Endothelial Keratoplasty (DMEK) and Descemet Stripping Automated Endothelial Keratoplasty (DSAEK). Corneal densitometry is a quantitative assessment that objectively evaluates corneal clar...

Descripción completa

Detalles Bibliográficos
Autores principales: Ballesteros-Sánchez, Antonio, Peraza-Nieves, Jorge, Casablanca-Piñera, Anna, Rodríguez-Calvo-De-Mora, Marina, Catalán-Coronado, Saray, Torras-Sanvicens, Josep, Borroni, Davide, Sánchez-González, José-María, Rocha-De-Lossada, Carlos
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10672394/
https://www.ncbi.nlm.nih.gov/pubmed/38002744
http://dx.doi.org/10.3390/jcm12227133
_version_ 1785149518968258560
author Ballesteros-Sánchez, Antonio
Peraza-Nieves, Jorge
Casablanca-Piñera, Anna
Rodríguez-Calvo-De-Mora, Marina
Catalán-Coronado, Saray
Torras-Sanvicens, Josep
Borroni, Davide
Sánchez-González, José-María
Rocha-De-Lossada, Carlos
author_facet Ballesteros-Sánchez, Antonio
Peraza-Nieves, Jorge
Casablanca-Piñera, Anna
Rodríguez-Calvo-De-Mora, Marina
Catalán-Coronado, Saray
Torras-Sanvicens, Josep
Borroni, Davide
Sánchez-González, José-María
Rocha-De-Lossada, Carlos
author_sort Ballesteros-Sánchez, Antonio
collection PubMed
description Background: To compare corneal densitometry (CD) patterns at the graft–host interface between Descemet Membrane Endothelial Keratoplasty (DMEK) and Descemet Stripping Automated Endothelial Keratoplasty (DSAEK). Corneal densitometry is a quantitative assessment that objectively evaluates corneal clarity and optical quality by measuring the light backscatter from the cornea. Methods: Fifty-one eyes that received DMEK or DSAEK surgery for corneal endothelium dysfunction were evaluated. The primary endpoint included CD patterns at the graft–host interface, which were assessed by the Pentacam HR device at the center point of the corneal horizontal meridian (CD(central)), and at six points on the central circumference of the cornea (with a total diameter of 4 mm) (CD(I,II,III,IV,V,VI)). Secondary endpoints included the best-corrected distance visual acuity (BCDVA), central corneal thickness (CCT), and graft thickness (GT). All of the evaluations were performed at follow-up appointments one, three, six and twelve months after the procedure. Results: DMEK showed a significant overall CD reduction of −7.9 ± 8.5 grayscale unit (GSU) compared to DSAEK (p < 0.001). In addition, the DMEK group showed significantly lower CD(Central,I,II,III,IV,V,VI) values at follow-up appointments one, three, six and twelve months after the procedure compared to the DSAEK group (p < 0.001). BCDVA, CCT and GT were in favor of the DMEK group with a mean value of 0.39 ± 0.35 LogMar, 552.2 ± 71.1 µm and 11.03 ± 1.4 µm, respectively (p < 0.001). Conclusions: CD patterns at the graft–host interface seem to be different depending on the endothelial keratoplasty procedure. This provides specific insight into CD changes in this critical region of surgery, which may provide a better understanding of the postoperative evolution of these patients.
format Online
Article
Text
id pubmed-10672394
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-106723942023-11-16 Scheimpflug Corneal Densitometry Patterns at the Graft–Host Interface in DMEK and DSAEK: A 12-Month Longitudinal Comparative Study Ballesteros-Sánchez, Antonio Peraza-Nieves, Jorge Casablanca-Piñera, Anna Rodríguez-Calvo-De-Mora, Marina Catalán-Coronado, Saray Torras-Sanvicens, Josep Borroni, Davide Sánchez-González, José-María Rocha-De-Lossada, Carlos J Clin Med Article Background: To compare corneal densitometry (CD) patterns at the graft–host interface between Descemet Membrane Endothelial Keratoplasty (DMEK) and Descemet Stripping Automated Endothelial Keratoplasty (DSAEK). Corneal densitometry is a quantitative assessment that objectively evaluates corneal clarity and optical quality by measuring the light backscatter from the cornea. Methods: Fifty-one eyes that received DMEK or DSAEK surgery for corneal endothelium dysfunction were evaluated. The primary endpoint included CD patterns at the graft–host interface, which were assessed by the Pentacam HR device at the center point of the corneal horizontal meridian (CD(central)), and at six points on the central circumference of the cornea (with a total diameter of 4 mm) (CD(I,II,III,IV,V,VI)). Secondary endpoints included the best-corrected distance visual acuity (BCDVA), central corneal thickness (CCT), and graft thickness (GT). All of the evaluations were performed at follow-up appointments one, three, six and twelve months after the procedure. Results: DMEK showed a significant overall CD reduction of −7.9 ± 8.5 grayscale unit (GSU) compared to DSAEK (p < 0.001). In addition, the DMEK group showed significantly lower CD(Central,I,II,III,IV,V,VI) values at follow-up appointments one, three, six and twelve months after the procedure compared to the DSAEK group (p < 0.001). BCDVA, CCT and GT were in favor of the DMEK group with a mean value of 0.39 ± 0.35 LogMar, 552.2 ± 71.1 µm and 11.03 ± 1.4 µm, respectively (p < 0.001). Conclusions: CD patterns at the graft–host interface seem to be different depending on the endothelial keratoplasty procedure. This provides specific insight into CD changes in this critical region of surgery, which may provide a better understanding of the postoperative evolution of these patients. MDPI 2023-11-16 /pmc/articles/PMC10672394/ /pubmed/38002744 http://dx.doi.org/10.3390/jcm12227133 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ballesteros-Sánchez, Antonio
Peraza-Nieves, Jorge
Casablanca-Piñera, Anna
Rodríguez-Calvo-De-Mora, Marina
Catalán-Coronado, Saray
Torras-Sanvicens, Josep
Borroni, Davide
Sánchez-González, José-María
Rocha-De-Lossada, Carlos
Scheimpflug Corneal Densitometry Patterns at the Graft–Host Interface in DMEK and DSAEK: A 12-Month Longitudinal Comparative Study
title Scheimpflug Corneal Densitometry Patterns at the Graft–Host Interface in DMEK and DSAEK: A 12-Month Longitudinal Comparative Study
title_full Scheimpflug Corneal Densitometry Patterns at the Graft–Host Interface in DMEK and DSAEK: A 12-Month Longitudinal Comparative Study
title_fullStr Scheimpflug Corneal Densitometry Patterns at the Graft–Host Interface in DMEK and DSAEK: A 12-Month Longitudinal Comparative Study
title_full_unstemmed Scheimpflug Corneal Densitometry Patterns at the Graft–Host Interface in DMEK and DSAEK: A 12-Month Longitudinal Comparative Study
title_short Scheimpflug Corneal Densitometry Patterns at the Graft–Host Interface in DMEK and DSAEK: A 12-Month Longitudinal Comparative Study
title_sort scheimpflug corneal densitometry patterns at the graft–host interface in dmek and dsaek: a 12-month longitudinal comparative study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10672394/
https://www.ncbi.nlm.nih.gov/pubmed/38002744
http://dx.doi.org/10.3390/jcm12227133
work_keys_str_mv AT ballesterossanchezantonio scheimpflugcornealdensitometrypatternsatthegrafthostinterfaceindmekanddsaeka12monthlongitudinalcomparativestudy
AT perazanievesjorge scheimpflugcornealdensitometrypatternsatthegrafthostinterfaceindmekanddsaeka12monthlongitudinalcomparativestudy
AT casablancapineraanna scheimpflugcornealdensitometrypatternsatthegrafthostinterfaceindmekanddsaeka12monthlongitudinalcomparativestudy
AT rodriguezcalvodemoramarina scheimpflugcornealdensitometrypatternsatthegrafthostinterfaceindmekanddsaeka12monthlongitudinalcomparativestudy
AT catalancoronadosaray scheimpflugcornealdensitometrypatternsatthegrafthostinterfaceindmekanddsaeka12monthlongitudinalcomparativestudy
AT torrassanvicensjosep scheimpflugcornealdensitometrypatternsatthegrafthostinterfaceindmekanddsaeka12monthlongitudinalcomparativestudy
AT borronidavide scheimpflugcornealdensitometrypatternsatthegrafthostinterfaceindmekanddsaeka12monthlongitudinalcomparativestudy
AT sanchezgonzalezjosemaria scheimpflugcornealdensitometrypatternsatthegrafthostinterfaceindmekanddsaeka12monthlongitudinalcomparativestudy
AT rochadelossadacarlos scheimpflugcornealdensitometrypatternsatthegrafthostinterfaceindmekanddsaeka12monthlongitudinalcomparativestudy