Cargando…

Incidental Indeterminate Renal Lesions: Distinguishing Non-Enhancing from Potential Enhancing Renal Lesions Using Iodine Quantification on Portal Venous Dual-Layer Spectral CT

The purpose of our study is to determine a threshold for iodine quantification to distinguish definitely non-enhancing benign renal lesions from potential enhancing masses on portal venous dual-layer spectral computed tomography (CT) to reduce the need for additional multiphase CT. In this single-ce...

Descripción completa

Detalles Bibliográficos
Autores principales: van der Star, Simone, de Jong, Pim A., Kok, Madeleine
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10672440/
https://www.ncbi.nlm.nih.gov/pubmed/38003860
http://dx.doi.org/10.3390/jpm13111546
_version_ 1785140391782121472
author van der Star, Simone
de Jong, Pim A.
Kok, Madeleine
author_facet van der Star, Simone
de Jong, Pim A.
Kok, Madeleine
author_sort van der Star, Simone
collection PubMed
description The purpose of our study is to determine a threshold for iodine quantification to distinguish definitely non-enhancing benign renal lesions from potential enhancing masses on portal venous dual-layer spectral computed tomography (CT) to reduce the need for additional multiphase CT. In this single-center retrospective study, patients (≥18 years) scanned between April 2021 and January 2023 following the local renal CT protocol were included. Exclusion criteria were patients without renal lesions, lesions smaller than 10 mm, only fat-containing lesions, abscesses or infarction, follow-up after radiofrequent ablation, wrong scan protocol, or artefacts. Scans were performed on a dual layer detector-based spectral CT (CT 7500, Philips Healthcare, Best, The Netherlands). Iodine concentration (mgI/mL) in renal lesions was determined using spectral data. Analyses were performed for all lesions and for lesions of >30 HU on portal venous CT. Enhancement on multiphase CT (≥20 ΔHU from true unenhanced (TUE) to portal venous phase (PVP) CT) was used as reference standard. To determine thresholds for iodine concentration receiver operating characteristic (ROC) curves, area under the curve (AUC) and 95% confidence intervals were calculated. To obtain thresholds for definite (non-)enhancement, 100% sensitivity with maximum specificity and 100% specificity with maximum sensitivity were noted. Data were measured using one reader. To assess interobserver agreement, a second reader performed measurements on the PVP CT scans. A total of 103 patients (62 years ± 14, 68 men) were included. We measured 328 renal lesions, 56 enhancing lesions (17%) in 38 patients and 272 non-enhancing lesions (83%) in 86 patients. The threshold for non-enhancing lesions was 0.76 mgI/mL or lower (100% sensitivity, 76% specificity). The threshold for a definite enhancing mass was 1.69 mgI/mL or higher (100% specificity, 78% sensitivity). A total of 77% of indeterminate lesions (>30 HU on PVP CT) in our study could be definitely characterized. Renal lesions can be definitively classified as non-enhancing or enhancing on PVP spectral CT using thresholds of 0.76 mgI/mL or 1.69 mgI/mL, respectively, eliminating the need for multiphase imaging.
format Online
Article
Text
id pubmed-10672440
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-106724402023-10-28 Incidental Indeterminate Renal Lesions: Distinguishing Non-Enhancing from Potential Enhancing Renal Lesions Using Iodine Quantification on Portal Venous Dual-Layer Spectral CT van der Star, Simone de Jong, Pim A. Kok, Madeleine J Pers Med Article The purpose of our study is to determine a threshold for iodine quantification to distinguish definitely non-enhancing benign renal lesions from potential enhancing masses on portal venous dual-layer spectral computed tomography (CT) to reduce the need for additional multiphase CT. In this single-center retrospective study, patients (≥18 years) scanned between April 2021 and January 2023 following the local renal CT protocol were included. Exclusion criteria were patients without renal lesions, lesions smaller than 10 mm, only fat-containing lesions, abscesses or infarction, follow-up after radiofrequent ablation, wrong scan protocol, or artefacts. Scans were performed on a dual layer detector-based spectral CT (CT 7500, Philips Healthcare, Best, The Netherlands). Iodine concentration (mgI/mL) in renal lesions was determined using spectral data. Analyses were performed for all lesions and for lesions of >30 HU on portal venous CT. Enhancement on multiphase CT (≥20 ΔHU from true unenhanced (TUE) to portal venous phase (PVP) CT) was used as reference standard. To determine thresholds for iodine concentration receiver operating characteristic (ROC) curves, area under the curve (AUC) and 95% confidence intervals were calculated. To obtain thresholds for definite (non-)enhancement, 100% sensitivity with maximum specificity and 100% specificity with maximum sensitivity were noted. Data were measured using one reader. To assess interobserver agreement, a second reader performed measurements on the PVP CT scans. A total of 103 patients (62 years ± 14, 68 men) were included. We measured 328 renal lesions, 56 enhancing lesions (17%) in 38 patients and 272 non-enhancing lesions (83%) in 86 patients. The threshold for non-enhancing lesions was 0.76 mgI/mL or lower (100% sensitivity, 76% specificity). The threshold for a definite enhancing mass was 1.69 mgI/mL or higher (100% specificity, 78% sensitivity). A total of 77% of indeterminate lesions (>30 HU on PVP CT) in our study could be definitely characterized. Renal lesions can be definitively classified as non-enhancing or enhancing on PVP spectral CT using thresholds of 0.76 mgI/mL or 1.69 mgI/mL, respectively, eliminating the need for multiphase imaging. MDPI 2023-10-28 /pmc/articles/PMC10672440/ /pubmed/38003860 http://dx.doi.org/10.3390/jpm13111546 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
van der Star, Simone
de Jong, Pim A.
Kok, Madeleine
Incidental Indeterminate Renal Lesions: Distinguishing Non-Enhancing from Potential Enhancing Renal Lesions Using Iodine Quantification on Portal Venous Dual-Layer Spectral CT
title Incidental Indeterminate Renal Lesions: Distinguishing Non-Enhancing from Potential Enhancing Renal Lesions Using Iodine Quantification on Portal Venous Dual-Layer Spectral CT
title_full Incidental Indeterminate Renal Lesions: Distinguishing Non-Enhancing from Potential Enhancing Renal Lesions Using Iodine Quantification on Portal Venous Dual-Layer Spectral CT
title_fullStr Incidental Indeterminate Renal Lesions: Distinguishing Non-Enhancing from Potential Enhancing Renal Lesions Using Iodine Quantification on Portal Venous Dual-Layer Spectral CT
title_full_unstemmed Incidental Indeterminate Renal Lesions: Distinguishing Non-Enhancing from Potential Enhancing Renal Lesions Using Iodine Quantification on Portal Venous Dual-Layer Spectral CT
title_short Incidental Indeterminate Renal Lesions: Distinguishing Non-Enhancing from Potential Enhancing Renal Lesions Using Iodine Quantification on Portal Venous Dual-Layer Spectral CT
title_sort incidental indeterminate renal lesions: distinguishing non-enhancing from potential enhancing renal lesions using iodine quantification on portal venous dual-layer spectral ct
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10672440/
https://www.ncbi.nlm.nih.gov/pubmed/38003860
http://dx.doi.org/10.3390/jpm13111546
work_keys_str_mv AT vanderstarsimone incidentalindeterminaterenallesionsdistinguishingnonenhancingfrompotentialenhancingrenallesionsusingiodinequantificationonportalvenousduallayerspectralct
AT dejongpima incidentalindeterminaterenallesionsdistinguishingnonenhancingfrompotentialenhancingrenallesionsusingiodinequantificationonportalvenousduallayerspectralct
AT kokmadeleine incidentalindeterminaterenallesionsdistinguishingnonenhancingfrompotentialenhancingrenallesionsusingiodinequantificationonportalvenousduallayerspectralct