Cargando…
Improving Chest Monitoring through Magnetic Resonance Angiogram Image Contrast Enhancement
Magnetic resonance angiography is a medical procedure used to offer an image of the blood vessels and organs of the body. Given the worldwide spread of cardiovascular diseases, more and more resources are invested in treating them. One of the most modern treatments involves the acquisition of images...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10672579/ https://www.ncbi.nlm.nih.gov/pubmed/38004300 http://dx.doi.org/10.3390/life13112160 |
_version_ | 1785140424404369408 |
---|---|
author | Arvinti, Beatrice Isar, Alexandru |
author_facet | Arvinti, Beatrice Isar, Alexandru |
author_sort | Arvinti, Beatrice |
collection | PubMed |
description | Magnetic resonance angiography is a medical procedure used to offer an image of the blood vessels and organs of the body. Given the worldwide spread of cardiovascular diseases, more and more resources are invested in treating them. One of the most modern treatments involves the acquisition of images of the heart. Sometimes the contrast of these images is not satisfactory. Injecting invasive enhancement substances to obtain a better view of the cardiac route is not advisable. However, software algorithms can solve the problem. This study proposes and tests a local adaptive contrast-adjustment algorithm using the dual-tree complex wavelet transform. The method has been tested with medical data from a public database to allow comparisons to other methods. The selected algorithm further improved the contrast of images. The performances are given for evaluation, both visually (to help doctors make accurate diagnoses) and in parametric form (to show engineers which parts of the algorithm might need improvement). Compared to other contrast enhancement methods, the proposed wavelet algorithm shows good results and greater stability. Thus, we aim to avoid future pointless complications due to unnecessary contrast substances. |
format | Online Article Text |
id | pubmed-10672579 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-106725792023-11-03 Improving Chest Monitoring through Magnetic Resonance Angiogram Image Contrast Enhancement Arvinti, Beatrice Isar, Alexandru Life (Basel) Article Magnetic resonance angiography is a medical procedure used to offer an image of the blood vessels and organs of the body. Given the worldwide spread of cardiovascular diseases, more and more resources are invested in treating them. One of the most modern treatments involves the acquisition of images of the heart. Sometimes the contrast of these images is not satisfactory. Injecting invasive enhancement substances to obtain a better view of the cardiac route is not advisable. However, software algorithms can solve the problem. This study proposes and tests a local adaptive contrast-adjustment algorithm using the dual-tree complex wavelet transform. The method has been tested with medical data from a public database to allow comparisons to other methods. The selected algorithm further improved the contrast of images. The performances are given for evaluation, both visually (to help doctors make accurate diagnoses) and in parametric form (to show engineers which parts of the algorithm might need improvement). Compared to other contrast enhancement methods, the proposed wavelet algorithm shows good results and greater stability. Thus, we aim to avoid future pointless complications due to unnecessary contrast substances. MDPI 2023-11-03 /pmc/articles/PMC10672579/ /pubmed/38004300 http://dx.doi.org/10.3390/life13112160 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Arvinti, Beatrice Isar, Alexandru Improving Chest Monitoring through Magnetic Resonance Angiogram Image Contrast Enhancement |
title | Improving Chest Monitoring through Magnetic Resonance Angiogram Image Contrast Enhancement |
title_full | Improving Chest Monitoring through Magnetic Resonance Angiogram Image Contrast Enhancement |
title_fullStr | Improving Chest Monitoring through Magnetic Resonance Angiogram Image Contrast Enhancement |
title_full_unstemmed | Improving Chest Monitoring through Magnetic Resonance Angiogram Image Contrast Enhancement |
title_short | Improving Chest Monitoring through Magnetic Resonance Angiogram Image Contrast Enhancement |
title_sort | improving chest monitoring through magnetic resonance angiogram image contrast enhancement |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10672579/ https://www.ncbi.nlm.nih.gov/pubmed/38004300 http://dx.doi.org/10.3390/life13112160 |
work_keys_str_mv | AT arvintibeatrice improvingchestmonitoringthroughmagneticresonanceangiogramimagecontrastenhancement AT isaralexandru improvingchestmonitoringthroughmagneticresonanceangiogramimagecontrastenhancement |