Cargando…
Innovative Curved-Tip Reactor for Non-Thermal Plasma and Plasma-Treated Water Generation: Synergistic Impact Comparison with Sodium Hypochlorite in Dental Root Canal Disinfection
Non-thermal plasmas (NTPs), known as cold atmospheric plasmas (CAPs), hold great potential for diverse medical applications, including dentistry. However, traditional linear and rigid dielectric barrier discharge reactors used for NTP generation encounter limitations in accessing oral cavities and r...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10672626/ https://www.ncbi.nlm.nih.gov/pubmed/38005133 http://dx.doi.org/10.3390/ma16227204 |
_version_ | 1785149539389276160 |
---|---|
author | Arguello-Sánchez, Raúl López-Callejas, Régulo Rodríguez-Méndez, Benjamín Gonzalo Scougall-Vilchis, Rogelio Velázquez-Enríquez, Ulises Mercado-Cabrera, Antonio Peña-Eguiluz, Rosendo Valencia-Alvarado, Raúl Medina-Solís, Carlo Eduardo |
author_facet | Arguello-Sánchez, Raúl López-Callejas, Régulo Rodríguez-Méndez, Benjamín Gonzalo Scougall-Vilchis, Rogelio Velázquez-Enríquez, Ulises Mercado-Cabrera, Antonio Peña-Eguiluz, Rosendo Valencia-Alvarado, Raúl Medina-Solís, Carlo Eduardo |
author_sort | Arguello-Sánchez, Raúl |
collection | PubMed |
description | Non-thermal plasmas (NTPs), known as cold atmospheric plasmas (CAPs), hold great potential for diverse medical applications, including dentistry. However, traditional linear and rigid dielectric barrier discharge reactors used for NTP generation encounter limitations in accessing oral cavities and root canals. To address this issue, we have developed an innovative NTP reactor featuring an angled end for improved accessibility. The central copper electrode, with a 0.59 mm diameter and adjustable length for desired angulation, is coated with zircon powder (ZrSiO(4)) to ensure stable NTP generation. This central electrode is housed within a stainless steel tube (3 mm internal diameter, 8 mm external diameter, and 100 mm length) with a 27° angle at one end, making it ergonomically suitable for oral applications. NTP generation involves polarizing the reactor electrodes with 13.56 MHz radio frequency signals, using helium gas as a working medium. We introduce plasma-treated water (PTW) as an adjunctive therapy to enhance biofilm eradication within root canals. A synergistic approach combining NTP and PTW is employed and compared to the gold standard (sodium hypochlorite, NaOCl), effectively neutralizing Enterococcus faecalis bacteria, even in scenarios involving biofilms. Moreover, applying NTP in both gaseous and liquid environments successfully achieves bacterial inactivation at varying treatment durations, demonstrating the device’s suitability for medical use in treating root canal biofilms. The proposed NTP reactor, characterized by its innovative design, offers a practical and specific approach to plasma treatment in dental applications. It holds promise in combatting bacterial infections in root canals and oral cavities. |
format | Online Article Text |
id | pubmed-10672626 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-106726262023-11-17 Innovative Curved-Tip Reactor for Non-Thermal Plasma and Plasma-Treated Water Generation: Synergistic Impact Comparison with Sodium Hypochlorite in Dental Root Canal Disinfection Arguello-Sánchez, Raúl López-Callejas, Régulo Rodríguez-Méndez, Benjamín Gonzalo Scougall-Vilchis, Rogelio Velázquez-Enríquez, Ulises Mercado-Cabrera, Antonio Peña-Eguiluz, Rosendo Valencia-Alvarado, Raúl Medina-Solís, Carlo Eduardo Materials (Basel) Article Non-thermal plasmas (NTPs), known as cold atmospheric plasmas (CAPs), hold great potential for diverse medical applications, including dentistry. However, traditional linear and rigid dielectric barrier discharge reactors used for NTP generation encounter limitations in accessing oral cavities and root canals. To address this issue, we have developed an innovative NTP reactor featuring an angled end for improved accessibility. The central copper electrode, with a 0.59 mm diameter and adjustable length for desired angulation, is coated with zircon powder (ZrSiO(4)) to ensure stable NTP generation. This central electrode is housed within a stainless steel tube (3 mm internal diameter, 8 mm external diameter, and 100 mm length) with a 27° angle at one end, making it ergonomically suitable for oral applications. NTP generation involves polarizing the reactor electrodes with 13.56 MHz radio frequency signals, using helium gas as a working medium. We introduce plasma-treated water (PTW) as an adjunctive therapy to enhance biofilm eradication within root canals. A synergistic approach combining NTP and PTW is employed and compared to the gold standard (sodium hypochlorite, NaOCl), effectively neutralizing Enterococcus faecalis bacteria, even in scenarios involving biofilms. Moreover, applying NTP in both gaseous and liquid environments successfully achieves bacterial inactivation at varying treatment durations, demonstrating the device’s suitability for medical use in treating root canal biofilms. The proposed NTP reactor, characterized by its innovative design, offers a practical and specific approach to plasma treatment in dental applications. It holds promise in combatting bacterial infections in root canals and oral cavities. MDPI 2023-11-17 /pmc/articles/PMC10672626/ /pubmed/38005133 http://dx.doi.org/10.3390/ma16227204 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Arguello-Sánchez, Raúl López-Callejas, Régulo Rodríguez-Méndez, Benjamín Gonzalo Scougall-Vilchis, Rogelio Velázquez-Enríquez, Ulises Mercado-Cabrera, Antonio Peña-Eguiluz, Rosendo Valencia-Alvarado, Raúl Medina-Solís, Carlo Eduardo Innovative Curved-Tip Reactor for Non-Thermal Plasma and Plasma-Treated Water Generation: Synergistic Impact Comparison with Sodium Hypochlorite in Dental Root Canal Disinfection |
title | Innovative Curved-Tip Reactor for Non-Thermal Plasma and Plasma-Treated Water Generation: Synergistic Impact Comparison with Sodium Hypochlorite in Dental Root Canal Disinfection |
title_full | Innovative Curved-Tip Reactor for Non-Thermal Plasma and Plasma-Treated Water Generation: Synergistic Impact Comparison with Sodium Hypochlorite in Dental Root Canal Disinfection |
title_fullStr | Innovative Curved-Tip Reactor for Non-Thermal Plasma and Plasma-Treated Water Generation: Synergistic Impact Comparison with Sodium Hypochlorite in Dental Root Canal Disinfection |
title_full_unstemmed | Innovative Curved-Tip Reactor for Non-Thermal Plasma and Plasma-Treated Water Generation: Synergistic Impact Comparison with Sodium Hypochlorite in Dental Root Canal Disinfection |
title_short | Innovative Curved-Tip Reactor for Non-Thermal Plasma and Plasma-Treated Water Generation: Synergistic Impact Comparison with Sodium Hypochlorite in Dental Root Canal Disinfection |
title_sort | innovative curved-tip reactor for non-thermal plasma and plasma-treated water generation: synergistic impact comparison with sodium hypochlorite in dental root canal disinfection |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10672626/ https://www.ncbi.nlm.nih.gov/pubmed/38005133 http://dx.doi.org/10.3390/ma16227204 |
work_keys_str_mv | AT arguellosanchezraul innovativecurvedtipreactorfornonthermalplasmaandplasmatreatedwatergenerationsynergisticimpactcomparisonwithsodiumhypochloriteindentalrootcanaldisinfection AT lopezcallejasregulo innovativecurvedtipreactorfornonthermalplasmaandplasmatreatedwatergenerationsynergisticimpactcomparisonwithsodiumhypochloriteindentalrootcanaldisinfection AT rodriguezmendezbenjamingonzalo innovativecurvedtipreactorfornonthermalplasmaandplasmatreatedwatergenerationsynergisticimpactcomparisonwithsodiumhypochloriteindentalrootcanaldisinfection AT scougallvilchisrogelio innovativecurvedtipreactorfornonthermalplasmaandplasmatreatedwatergenerationsynergisticimpactcomparisonwithsodiumhypochloriteindentalrootcanaldisinfection AT velazquezenriquezulises innovativecurvedtipreactorfornonthermalplasmaandplasmatreatedwatergenerationsynergisticimpactcomparisonwithsodiumhypochloriteindentalrootcanaldisinfection AT mercadocabreraantonio innovativecurvedtipreactorfornonthermalplasmaandplasmatreatedwatergenerationsynergisticimpactcomparisonwithsodiumhypochloriteindentalrootcanaldisinfection AT penaeguiluzrosendo innovativecurvedtipreactorfornonthermalplasmaandplasmatreatedwatergenerationsynergisticimpactcomparisonwithsodiumhypochloriteindentalrootcanaldisinfection AT valenciaalvaradoraul innovativecurvedtipreactorfornonthermalplasmaandplasmatreatedwatergenerationsynergisticimpactcomparisonwithsodiumhypochloriteindentalrootcanaldisinfection AT medinasoliscarloeduardo innovativecurvedtipreactorfornonthermalplasmaandplasmatreatedwatergenerationsynergisticimpactcomparisonwithsodiumhypochloriteindentalrootcanaldisinfection |