Cargando…
A Theoretical Study on the Spatiotemporal Variation in the Temperature Field in Linings of High-Water-Temperature Tunnels
On the basis of the theory of unsteady heat conduction, discrete equations for the unsteady temperature field in the secondary linings of high-water-temperature tunnels when considering the hydration heat of lining concrete were derived and established. Spatiotemporal variation in the temperature fi...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10672787/ https://www.ncbi.nlm.nih.gov/pubmed/38005069 http://dx.doi.org/10.3390/ma16227139 |
_version_ | 1785149553307025408 |
---|---|
author | Huang, Mingli Huang, Meng Li, Jiacheng Qian, Yuan |
author_facet | Huang, Mingli Huang, Meng Li, Jiacheng Qian, Yuan |
author_sort | Huang, Mingli |
collection | PubMed |
description | On the basis of the theory of unsteady heat conduction, discrete equations for the unsteady temperature field in the secondary linings of high-water-temperature tunnels when considering the hydration heat of lining concrete were derived and established. Spatiotemporal variation in the temperature field of tunnel linings was revealed through the analysis of numerical examples. Research demonstrates that the temperature of the secondary lining within a thickness range of approximately 15 cm near the tunnel clearance decreases sharply under the condition that the lining thickness is 35 cm. The higher the temperature on the lining’s outer surface, the more drastically the lining temperature decreases. When considering the hydration heat of lining concrete, the lining temperature increases to a certain extent after a sudden drop, reaching stability after approximately 20 h, and the lining temperature is approximately 1–2 °C higher than that without taking concrete hydration heat into account. The temperature difference between the tunnel lining’s core and its inner and outer surfaces is positively and negatively correlated with the temperature of the secondary lining’s outer surface, respectively. When the temperature of the secondary lining’s outer surface is not higher than 65 °C, the temperature difference between the tunnel lining’s core and its inner and outer surfaces is less than 20 °C. Conversely, it partially or completely exceeds 20 °C, in which case an insulation method is recommended to utilize to prevent thermal cracks in secondary linings triggered via a high temperature difference. |
format | Online Article Text |
id | pubmed-10672787 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-106727872023-11-13 A Theoretical Study on the Spatiotemporal Variation in the Temperature Field in Linings of High-Water-Temperature Tunnels Huang, Mingli Huang, Meng Li, Jiacheng Qian, Yuan Materials (Basel) Article On the basis of the theory of unsteady heat conduction, discrete equations for the unsteady temperature field in the secondary linings of high-water-temperature tunnels when considering the hydration heat of lining concrete were derived and established. Spatiotemporal variation in the temperature field of tunnel linings was revealed through the analysis of numerical examples. Research demonstrates that the temperature of the secondary lining within a thickness range of approximately 15 cm near the tunnel clearance decreases sharply under the condition that the lining thickness is 35 cm. The higher the temperature on the lining’s outer surface, the more drastically the lining temperature decreases. When considering the hydration heat of lining concrete, the lining temperature increases to a certain extent after a sudden drop, reaching stability after approximately 20 h, and the lining temperature is approximately 1–2 °C higher than that without taking concrete hydration heat into account. The temperature difference between the tunnel lining’s core and its inner and outer surfaces is positively and negatively correlated with the temperature of the secondary lining’s outer surface, respectively. When the temperature of the secondary lining’s outer surface is not higher than 65 °C, the temperature difference between the tunnel lining’s core and its inner and outer surfaces is less than 20 °C. Conversely, it partially or completely exceeds 20 °C, in which case an insulation method is recommended to utilize to prevent thermal cracks in secondary linings triggered via a high temperature difference. MDPI 2023-11-13 /pmc/articles/PMC10672787/ /pubmed/38005069 http://dx.doi.org/10.3390/ma16227139 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Huang, Mingli Huang, Meng Li, Jiacheng Qian, Yuan A Theoretical Study on the Spatiotemporal Variation in the Temperature Field in Linings of High-Water-Temperature Tunnels |
title | A Theoretical Study on the Spatiotemporal Variation in the Temperature Field in Linings of High-Water-Temperature Tunnels |
title_full | A Theoretical Study on the Spatiotemporal Variation in the Temperature Field in Linings of High-Water-Temperature Tunnels |
title_fullStr | A Theoretical Study on the Spatiotemporal Variation in the Temperature Field in Linings of High-Water-Temperature Tunnels |
title_full_unstemmed | A Theoretical Study on the Spatiotemporal Variation in the Temperature Field in Linings of High-Water-Temperature Tunnels |
title_short | A Theoretical Study on the Spatiotemporal Variation in the Temperature Field in Linings of High-Water-Temperature Tunnels |
title_sort | theoretical study on the spatiotemporal variation in the temperature field in linings of high-water-temperature tunnels |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10672787/ https://www.ncbi.nlm.nih.gov/pubmed/38005069 http://dx.doi.org/10.3390/ma16227139 |
work_keys_str_mv | AT huangmingli atheoreticalstudyonthespatiotemporalvariationinthetemperaturefieldinliningsofhighwatertemperaturetunnels AT huangmeng atheoreticalstudyonthespatiotemporalvariationinthetemperaturefieldinliningsofhighwatertemperaturetunnels AT lijiacheng atheoreticalstudyonthespatiotemporalvariationinthetemperaturefieldinliningsofhighwatertemperaturetunnels AT qianyuan atheoreticalstudyonthespatiotemporalvariationinthetemperaturefieldinliningsofhighwatertemperaturetunnels AT huangmingli theoreticalstudyonthespatiotemporalvariationinthetemperaturefieldinliningsofhighwatertemperaturetunnels AT huangmeng theoreticalstudyonthespatiotemporalvariationinthetemperaturefieldinliningsofhighwatertemperaturetunnels AT lijiacheng theoreticalstudyonthespatiotemporalvariationinthetemperaturefieldinliningsofhighwatertemperaturetunnels AT qianyuan theoreticalstudyonthespatiotemporalvariationinthetemperaturefieldinliningsofhighwatertemperaturetunnels |