A Theoretical Study on the Spatiotemporal Variation in the Temperature Field in Linings of High-Water-Temperature Tunnels

On the basis of the theory of unsteady heat conduction, discrete equations for the unsteady temperature field in the secondary linings of high-water-temperature tunnels when considering the hydration heat of lining concrete were derived and established. Spatiotemporal variation in the temperature fi...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Mingli, Huang, Meng, Li, Jiacheng, Qian, Yuan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10672787/
https://www.ncbi.nlm.nih.gov/pubmed/38005069
http://dx.doi.org/10.3390/ma16227139
_version_ 1785149553307025408
author Huang, Mingli
Huang, Meng
Li, Jiacheng
Qian, Yuan
author_facet Huang, Mingli
Huang, Meng
Li, Jiacheng
Qian, Yuan
author_sort Huang, Mingli
collection PubMed
description On the basis of the theory of unsteady heat conduction, discrete equations for the unsteady temperature field in the secondary linings of high-water-temperature tunnels when considering the hydration heat of lining concrete were derived and established. Spatiotemporal variation in the temperature field of tunnel linings was revealed through the analysis of numerical examples. Research demonstrates that the temperature of the secondary lining within a thickness range of approximately 15 cm near the tunnel clearance decreases sharply under the condition that the lining thickness is 35 cm. The higher the temperature on the lining’s outer surface, the more drastically the lining temperature decreases. When considering the hydration heat of lining concrete, the lining temperature increases to a certain extent after a sudden drop, reaching stability after approximately 20 h, and the lining temperature is approximately 1–2 °C higher than that without taking concrete hydration heat into account. The temperature difference between the tunnel lining’s core and its inner and outer surfaces is positively and negatively correlated with the temperature of the secondary lining’s outer surface, respectively. When the temperature of the secondary lining’s outer surface is not higher than 65 °C, the temperature difference between the tunnel lining’s core and its inner and outer surfaces is less than 20 °C. Conversely, it partially or completely exceeds 20 °C, in which case an insulation method is recommended to utilize to prevent thermal cracks in secondary linings triggered via a high temperature difference.
format Online
Article
Text
id pubmed-10672787
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-106727872023-11-13 A Theoretical Study on the Spatiotemporal Variation in the Temperature Field in Linings of High-Water-Temperature Tunnels Huang, Mingli Huang, Meng Li, Jiacheng Qian, Yuan Materials (Basel) Article On the basis of the theory of unsteady heat conduction, discrete equations for the unsteady temperature field in the secondary linings of high-water-temperature tunnels when considering the hydration heat of lining concrete were derived and established. Spatiotemporal variation in the temperature field of tunnel linings was revealed through the analysis of numerical examples. Research demonstrates that the temperature of the secondary lining within a thickness range of approximately 15 cm near the tunnel clearance decreases sharply under the condition that the lining thickness is 35 cm. The higher the temperature on the lining’s outer surface, the more drastically the lining temperature decreases. When considering the hydration heat of lining concrete, the lining temperature increases to a certain extent after a sudden drop, reaching stability after approximately 20 h, and the lining temperature is approximately 1–2 °C higher than that without taking concrete hydration heat into account. The temperature difference between the tunnel lining’s core and its inner and outer surfaces is positively and negatively correlated with the temperature of the secondary lining’s outer surface, respectively. When the temperature of the secondary lining’s outer surface is not higher than 65 °C, the temperature difference between the tunnel lining’s core and its inner and outer surfaces is less than 20 °C. Conversely, it partially or completely exceeds 20 °C, in which case an insulation method is recommended to utilize to prevent thermal cracks in secondary linings triggered via a high temperature difference. MDPI 2023-11-13 /pmc/articles/PMC10672787/ /pubmed/38005069 http://dx.doi.org/10.3390/ma16227139 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Huang, Mingli
Huang, Meng
Li, Jiacheng
Qian, Yuan
A Theoretical Study on the Spatiotemporal Variation in the Temperature Field in Linings of High-Water-Temperature Tunnels
title A Theoretical Study on the Spatiotemporal Variation in the Temperature Field in Linings of High-Water-Temperature Tunnels
title_full A Theoretical Study on the Spatiotemporal Variation in the Temperature Field in Linings of High-Water-Temperature Tunnels
title_fullStr A Theoretical Study on the Spatiotemporal Variation in the Temperature Field in Linings of High-Water-Temperature Tunnels
title_full_unstemmed A Theoretical Study on the Spatiotemporal Variation in the Temperature Field in Linings of High-Water-Temperature Tunnels
title_short A Theoretical Study on the Spatiotemporal Variation in the Temperature Field in Linings of High-Water-Temperature Tunnels
title_sort theoretical study on the spatiotemporal variation in the temperature field in linings of high-water-temperature tunnels
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10672787/
https://www.ncbi.nlm.nih.gov/pubmed/38005069
http://dx.doi.org/10.3390/ma16227139
work_keys_str_mv AT huangmingli atheoreticalstudyonthespatiotemporalvariationinthetemperaturefieldinliningsofhighwatertemperaturetunnels
AT huangmeng atheoreticalstudyonthespatiotemporalvariationinthetemperaturefieldinliningsofhighwatertemperaturetunnels
AT lijiacheng atheoreticalstudyonthespatiotemporalvariationinthetemperaturefieldinliningsofhighwatertemperaturetunnels
AT qianyuan atheoreticalstudyonthespatiotemporalvariationinthetemperaturefieldinliningsofhighwatertemperaturetunnels
AT huangmingli theoreticalstudyonthespatiotemporalvariationinthetemperaturefieldinliningsofhighwatertemperaturetunnels
AT huangmeng theoreticalstudyonthespatiotemporalvariationinthetemperaturefieldinliningsofhighwatertemperaturetunnels
AT lijiacheng theoreticalstudyonthespatiotemporalvariationinthetemperaturefieldinliningsofhighwatertemperaturetunnels
AT qianyuan theoreticalstudyonthespatiotemporalvariationinthetemperaturefieldinliningsofhighwatertemperaturetunnels