Cargando…
Study of a High-Precision Read-Out Integrated Circuit for Bridge Sensors
Bridge sensors are widely used in military and civilian fields, and their demand gradually increases each year. Digital sensors are widely used in the military and civilian fields. High-precision and low-power analog-to-digital converters (ADCs) as sensor read-out circuits are a research hotspot. Si...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10672819/ https://www.ncbi.nlm.nih.gov/pubmed/38004870 http://dx.doi.org/10.3390/mi14112013 |
_version_ | 1785140480347996160 |
---|---|
author | Li, Xiangyu Wang, Pengjun Ye, Hao He, Haonan Zhang, Xiaowei |
author_facet | Li, Xiangyu Wang, Pengjun Ye, Hao He, Haonan Zhang, Xiaowei |
author_sort | Li, Xiangyu |
collection | PubMed |
description | Bridge sensors are widely used in military and civilian fields, and their demand gradually increases each year. Digital sensors are widely used in the military and civilian fields. High-precision and low-power analog-to-digital converters (ADCs) as sensor read-out circuits are a research hotspot. Sigma-delta ADC circuits based on switched-capacitor topology have the advantages of high signal-to-noise ratio (SNR), good linearity, and better compatibility with CMOS processes. In this work, a fourth-order feed-forward sigma-delta modulator and a digital decimation filter are designed and implemented with a correlated double sampling technique (CDS) to suppress pre-integrator low-frequency noise. This work used an active pre-compensator circuit for deep phase compensation to improve the system’s stability in the sigma-delta modulator. The modulator’s local feedback factor is designed to be adjustable off-chip to eliminate the effect of process errors. A three-stage cascade structure was chosen for the post-stage digital filter, significantly reducing the number of operations and the required memory cells in the digital circuit. Finally, the layout design and engineering circuit were fabricated by a standard 0.35 μm CMOS process from Shanghai Hua Hong with a chip area of 9 mm(2). At a 5 V voltage supply and sampling frequency of 6.144 MHz, the modulator power consumption is 13 mW, the maximum input signal amplitude is −3 dBFs, the 1 Hz dynamic range is about 118 dB, the modulator signal-to-noise ratio can reach 110.5 dB when the signal bandwidth is 24 kHz, the practical bit is about 18.05 bits, and the harmonic distortion is about −113 dB, which meets the design requirements. The output bit stream is 24 bits. |
format | Online Article Text |
id | pubmed-10672819 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-106728192023-10-29 Study of a High-Precision Read-Out Integrated Circuit for Bridge Sensors Li, Xiangyu Wang, Pengjun Ye, Hao He, Haonan Zhang, Xiaowei Micromachines (Basel) Article Bridge sensors are widely used in military and civilian fields, and their demand gradually increases each year. Digital sensors are widely used in the military and civilian fields. High-precision and low-power analog-to-digital converters (ADCs) as sensor read-out circuits are a research hotspot. Sigma-delta ADC circuits based on switched-capacitor topology have the advantages of high signal-to-noise ratio (SNR), good linearity, and better compatibility with CMOS processes. In this work, a fourth-order feed-forward sigma-delta modulator and a digital decimation filter are designed and implemented with a correlated double sampling technique (CDS) to suppress pre-integrator low-frequency noise. This work used an active pre-compensator circuit for deep phase compensation to improve the system’s stability in the sigma-delta modulator. The modulator’s local feedback factor is designed to be adjustable off-chip to eliminate the effect of process errors. A three-stage cascade structure was chosen for the post-stage digital filter, significantly reducing the number of operations and the required memory cells in the digital circuit. Finally, the layout design and engineering circuit were fabricated by a standard 0.35 μm CMOS process from Shanghai Hua Hong with a chip area of 9 mm(2). At a 5 V voltage supply and sampling frequency of 6.144 MHz, the modulator power consumption is 13 mW, the maximum input signal amplitude is −3 dBFs, the 1 Hz dynamic range is about 118 dB, the modulator signal-to-noise ratio can reach 110.5 dB when the signal bandwidth is 24 kHz, the practical bit is about 18.05 bits, and the harmonic distortion is about −113 dB, which meets the design requirements. The output bit stream is 24 bits. MDPI 2023-10-29 /pmc/articles/PMC10672819/ /pubmed/38004870 http://dx.doi.org/10.3390/mi14112013 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Li, Xiangyu Wang, Pengjun Ye, Hao He, Haonan Zhang, Xiaowei Study of a High-Precision Read-Out Integrated Circuit for Bridge Sensors |
title | Study of a High-Precision Read-Out Integrated Circuit for Bridge Sensors |
title_full | Study of a High-Precision Read-Out Integrated Circuit for Bridge Sensors |
title_fullStr | Study of a High-Precision Read-Out Integrated Circuit for Bridge Sensors |
title_full_unstemmed | Study of a High-Precision Read-Out Integrated Circuit for Bridge Sensors |
title_short | Study of a High-Precision Read-Out Integrated Circuit for Bridge Sensors |
title_sort | study of a high-precision read-out integrated circuit for bridge sensors |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10672819/ https://www.ncbi.nlm.nih.gov/pubmed/38004870 http://dx.doi.org/10.3390/mi14112013 |
work_keys_str_mv | AT lixiangyu studyofahighprecisionreadoutintegratedcircuitforbridgesensors AT wangpengjun studyofahighprecisionreadoutintegratedcircuitforbridgesensors AT yehao studyofahighprecisionreadoutintegratedcircuitforbridgesensors AT hehaonan studyofahighprecisionreadoutintegratedcircuitforbridgesensors AT zhangxiaowei studyofahighprecisionreadoutintegratedcircuitforbridgesensors |