Cargando…

Bond Wire Fatigue of Au, Cu, and PCC in Power LED Packages †

Bond wire failure, primarily wire neck breakage, in power LED devices due to thermomechanical fatigue is one of the main reliability issues in power LED devices. Currently, the standard testing methods to evaluate the device’s lifetime involve time-consuming thermal cycling or thermal shock tests. W...

Descripción completa

Detalles Bibliográficos
Autores principales: Czerny, Bernhard, Schuh, Sebastian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10672991/
https://www.ncbi.nlm.nih.gov/pubmed/38004859
http://dx.doi.org/10.3390/mi14112002
_version_ 1785140517114216448
author Czerny, Bernhard
Schuh, Sebastian
author_facet Czerny, Bernhard
Schuh, Sebastian
author_sort Czerny, Bernhard
collection PubMed
description Bond wire failure, primarily wire neck breakage, in power LED devices due to thermomechanical fatigue is one of the main reliability issues in power LED devices. Currently, the standard testing methods to evaluate the device’s lifetime involve time-consuming thermal cycling or thermal shock tests. While numerical or simulation methods are used as convenient and quick alternatives, obtaining data from material lifetime models with accurate reliability and without experimental fatigue has proven challenging. To address this issue, a mechanical fatigue testing system was developed with the purpose of inducing mechanical stresses in the critical region of the bond wire connection above the ball bond. The aim was to accelerate fatigue cracks at this bottleneck, inducing a similar failure mode as observed during thermal tests. Experimental investigations were conducted on Au, Cu, and Pd-coated Cu bonding wires, each with a diameter of 25 µm, using both low- and high-frequency excitation. The lifetime of the wire bond obtained from these tests ranged from 100 to 1,000,000 cycles. This proposed testing method offers material lifetime data in a significantly shorter timeframe and requires minimal sample preparation. Additionally, finite element simulations were performed to quantify the stresses at the wire neck, facilitating comparisons to conventional testing methods, fatigue test results under various operating conditions, material models, and design evaluations of the fine wire bond reliability in LED and microelectronic packages.
format Online
Article
Text
id pubmed-10672991
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-106729912023-10-28 Bond Wire Fatigue of Au, Cu, and PCC in Power LED Packages † Czerny, Bernhard Schuh, Sebastian Micromachines (Basel) Article Bond wire failure, primarily wire neck breakage, in power LED devices due to thermomechanical fatigue is one of the main reliability issues in power LED devices. Currently, the standard testing methods to evaluate the device’s lifetime involve time-consuming thermal cycling or thermal shock tests. While numerical or simulation methods are used as convenient and quick alternatives, obtaining data from material lifetime models with accurate reliability and without experimental fatigue has proven challenging. To address this issue, a mechanical fatigue testing system was developed with the purpose of inducing mechanical stresses in the critical region of the bond wire connection above the ball bond. The aim was to accelerate fatigue cracks at this bottleneck, inducing a similar failure mode as observed during thermal tests. Experimental investigations were conducted on Au, Cu, and Pd-coated Cu bonding wires, each with a diameter of 25 µm, using both low- and high-frequency excitation. The lifetime of the wire bond obtained from these tests ranged from 100 to 1,000,000 cycles. This proposed testing method offers material lifetime data in a significantly shorter timeframe and requires minimal sample preparation. Additionally, finite element simulations were performed to quantify the stresses at the wire neck, facilitating comparisons to conventional testing methods, fatigue test results under various operating conditions, material models, and design evaluations of the fine wire bond reliability in LED and microelectronic packages. MDPI 2023-10-28 /pmc/articles/PMC10672991/ /pubmed/38004859 http://dx.doi.org/10.3390/mi14112002 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Czerny, Bernhard
Schuh, Sebastian
Bond Wire Fatigue of Au, Cu, and PCC in Power LED Packages †
title Bond Wire Fatigue of Au, Cu, and PCC in Power LED Packages †
title_full Bond Wire Fatigue of Au, Cu, and PCC in Power LED Packages †
title_fullStr Bond Wire Fatigue of Au, Cu, and PCC in Power LED Packages †
title_full_unstemmed Bond Wire Fatigue of Au, Cu, and PCC in Power LED Packages †
title_short Bond Wire Fatigue of Au, Cu, and PCC in Power LED Packages †
title_sort bond wire fatigue of au, cu, and pcc in power led packages †
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10672991/
https://www.ncbi.nlm.nih.gov/pubmed/38004859
http://dx.doi.org/10.3390/mi14112002
work_keys_str_mv AT czernybernhard bondwirefatigueofaucuandpccinpowerledpackages
AT schuhsebastian bondwirefatigueofaucuandpccinpowerledpackages