Cargando…
Design and Experimental Evaluation of a Dual-Cantilever Piezoelectric Film Sensor with a Broadband Response and High Sensitivity
Cantilever-beam-type PVDF (Polyvinylidene Fluoride) piezoelectric film sensors are commonly utilized for vibration signal detection due to their simple structures and ease of processing. Traditional cantilevered PVDF piezoelectric film sensors are susceptible to the influence of the second-order vib...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10673016/ https://www.ncbi.nlm.nih.gov/pubmed/38004964 http://dx.doi.org/10.3390/mi14112108 |
_version_ | 1785149572014669824 |
---|---|
author | Xin, Wei He, Zhaoyang Zhao, Chaocheng |
author_facet | Xin, Wei He, Zhaoyang Zhao, Chaocheng |
author_sort | Xin, Wei |
collection | PubMed |
description | Cantilever-beam-type PVDF (Polyvinylidene Fluoride) piezoelectric film sensors are commonly utilized for vibration signal detection due to their simple structures and ease of processing. Traditional cantilevered PVDF piezoelectric film sensors are susceptible to the influence of the second-order vibration mode and have a low lateral stress distribution at the free end, which limit their measurement bandwidth and sensitivity. This study is on the design of a dual-cantilever PVDF piezoelectric film sensor based on the principle of cantilevered piezoelectric film sensors. The results of the experiments indicate that, compared to a typical single-arm piezoelectric cantilever beam vibration sensor, the developed sensor has a longer second-order natural frequency that ranges from 112 Hz to 453 Hz, while the first-order natural frequency is maintained at around 12 Hz. This leads to a better ratio of the second-order natural frequency to the first-order natural frequency and a wider frequency response range. At the same time, the sensitivity is increased by a factor of 3.48. |
format | Online Article Text |
id | pubmed-10673016 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-106730162023-11-17 Design and Experimental Evaluation of a Dual-Cantilever Piezoelectric Film Sensor with a Broadband Response and High Sensitivity Xin, Wei He, Zhaoyang Zhao, Chaocheng Micromachines (Basel) Article Cantilever-beam-type PVDF (Polyvinylidene Fluoride) piezoelectric film sensors are commonly utilized for vibration signal detection due to their simple structures and ease of processing. Traditional cantilevered PVDF piezoelectric film sensors are susceptible to the influence of the second-order vibration mode and have a low lateral stress distribution at the free end, which limit their measurement bandwidth and sensitivity. This study is on the design of a dual-cantilever PVDF piezoelectric film sensor based on the principle of cantilevered piezoelectric film sensors. The results of the experiments indicate that, compared to a typical single-arm piezoelectric cantilever beam vibration sensor, the developed sensor has a longer second-order natural frequency that ranges from 112 Hz to 453 Hz, while the first-order natural frequency is maintained at around 12 Hz. This leads to a better ratio of the second-order natural frequency to the first-order natural frequency and a wider frequency response range. At the same time, the sensitivity is increased by a factor of 3.48. MDPI 2023-11-17 /pmc/articles/PMC10673016/ /pubmed/38004964 http://dx.doi.org/10.3390/mi14112108 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Xin, Wei He, Zhaoyang Zhao, Chaocheng Design and Experimental Evaluation of a Dual-Cantilever Piezoelectric Film Sensor with a Broadband Response and High Sensitivity |
title | Design and Experimental Evaluation of a Dual-Cantilever Piezoelectric Film Sensor with a Broadband Response and High Sensitivity |
title_full | Design and Experimental Evaluation of a Dual-Cantilever Piezoelectric Film Sensor with a Broadband Response and High Sensitivity |
title_fullStr | Design and Experimental Evaluation of a Dual-Cantilever Piezoelectric Film Sensor with a Broadband Response and High Sensitivity |
title_full_unstemmed | Design and Experimental Evaluation of a Dual-Cantilever Piezoelectric Film Sensor with a Broadband Response and High Sensitivity |
title_short | Design and Experimental Evaluation of a Dual-Cantilever Piezoelectric Film Sensor with a Broadband Response and High Sensitivity |
title_sort | design and experimental evaluation of a dual-cantilever piezoelectric film sensor with a broadband response and high sensitivity |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10673016/ https://www.ncbi.nlm.nih.gov/pubmed/38004964 http://dx.doi.org/10.3390/mi14112108 |
work_keys_str_mv | AT xinwei designandexperimentalevaluationofadualcantileverpiezoelectricfilmsensorwithabroadbandresponseandhighsensitivity AT hezhaoyang designandexperimentalevaluationofadualcantileverpiezoelectricfilmsensorwithabroadbandresponseandhighsensitivity AT zhaochaocheng designandexperimentalevaluationofadualcantileverpiezoelectricfilmsensorwithabroadbandresponseandhighsensitivity |