Cargando…

Enhancing the Sensitivity of Lateral Flow Assay with Europium Nanoparticles for Accurate Human IgG Quantification

Accurate quantification of immunoglobulin G (IgG) levels is vital for understanding immune status and diagnosing various medical conditions. Lateral flow assays (LFAs) offer rapid and convenient diagnostic tools, but their sensitivity has been a limitation. Our research introduces a refined method i...

Descripción completa

Detalles Bibliográficos
Autores principales: Natarajan, Satheesh, Priye, Aashish
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10673117/
https://www.ncbi.nlm.nih.gov/pubmed/38004850
http://dx.doi.org/10.3390/mi14111993
_version_ 1785140547232464896
author Natarajan, Satheesh
Priye, Aashish
author_facet Natarajan, Satheesh
Priye, Aashish
author_sort Natarajan, Satheesh
collection PubMed
description Accurate quantification of immunoglobulin G (IgG) levels is vital for understanding immune status and diagnosing various medical conditions. Lateral flow assays (LFAs) offer rapid and convenient diagnostic tools, but their sensitivity has been a limitation. Our research introduces a refined method incorporating europium nanoparticles, enhancing both sensitivity and accuracy of LFAs in human IgG measurement. Utilizing a unique sandwich format, carboxylate-modified polystyrene Eu (III) chelate microparticles (CM-EUs) acted as the primary reporters. The concentrations of both detection and capture antibodies on the strip were optimized to bolster the LFA’s quantitative performance. The subsequent calibration curve between the IgG concentration and the measured intensity ratio (V(R)) established the linearity and analytical sensitivity of our method with a high correlation coefficient (r = 0.99) and an impressively low limit of detection (LoD = 0.04 ng/mL). Our precision assessment, segmented into intra-assay and inter-assay evaluations, showcases the method’s consistency and reproducibility. The LFA assay’s stability was established by demonstrating its resistance to degradation and affirming its potential for extended storage without a dip in performance. The study’s findings underscore the potential of this method to contribute to diagnostic medicine and improve patient care.
format Online
Article
Text
id pubmed-10673117
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-106731172023-10-27 Enhancing the Sensitivity of Lateral Flow Assay with Europium Nanoparticles for Accurate Human IgG Quantification Natarajan, Satheesh Priye, Aashish Micromachines (Basel) Article Accurate quantification of immunoglobulin G (IgG) levels is vital for understanding immune status and diagnosing various medical conditions. Lateral flow assays (LFAs) offer rapid and convenient diagnostic tools, but their sensitivity has been a limitation. Our research introduces a refined method incorporating europium nanoparticles, enhancing both sensitivity and accuracy of LFAs in human IgG measurement. Utilizing a unique sandwich format, carboxylate-modified polystyrene Eu (III) chelate microparticles (CM-EUs) acted as the primary reporters. The concentrations of both detection and capture antibodies on the strip were optimized to bolster the LFA’s quantitative performance. The subsequent calibration curve between the IgG concentration and the measured intensity ratio (V(R)) established the linearity and analytical sensitivity of our method with a high correlation coefficient (r = 0.99) and an impressively low limit of detection (LoD = 0.04 ng/mL). Our precision assessment, segmented into intra-assay and inter-assay evaluations, showcases the method’s consistency and reproducibility. The LFA assay’s stability was established by demonstrating its resistance to degradation and affirming its potential for extended storage without a dip in performance. The study’s findings underscore the potential of this method to contribute to diagnostic medicine and improve patient care. MDPI 2023-10-27 /pmc/articles/PMC10673117/ /pubmed/38004850 http://dx.doi.org/10.3390/mi14111993 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Natarajan, Satheesh
Priye, Aashish
Enhancing the Sensitivity of Lateral Flow Assay with Europium Nanoparticles for Accurate Human IgG Quantification
title Enhancing the Sensitivity of Lateral Flow Assay with Europium Nanoparticles for Accurate Human IgG Quantification
title_full Enhancing the Sensitivity of Lateral Flow Assay with Europium Nanoparticles for Accurate Human IgG Quantification
title_fullStr Enhancing the Sensitivity of Lateral Flow Assay with Europium Nanoparticles for Accurate Human IgG Quantification
title_full_unstemmed Enhancing the Sensitivity of Lateral Flow Assay with Europium Nanoparticles for Accurate Human IgG Quantification
title_short Enhancing the Sensitivity of Lateral Flow Assay with Europium Nanoparticles for Accurate Human IgG Quantification
title_sort enhancing the sensitivity of lateral flow assay with europium nanoparticles for accurate human igg quantification
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10673117/
https://www.ncbi.nlm.nih.gov/pubmed/38004850
http://dx.doi.org/10.3390/mi14111993
work_keys_str_mv AT natarajansatheesh enhancingthesensitivityoflateralflowassaywitheuropiumnanoparticlesforaccuratehumaniggquantification
AT priyeaashish enhancingthesensitivityoflateralflowassaywitheuropiumnanoparticlesforaccuratehumaniggquantification