Design of a Subretinal Injection Robot Based on the RCM Mechanism
This study presents an investigation focusing on the advancement of a robot designed for subretinal injections in the context of macular degeneration treatment. The technique of subretinal injection surgery stands as the most efficacious approach for the successful transplantation of stem cells into...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10673425/ https://www.ncbi.nlm.nih.gov/pubmed/38004855 http://dx.doi.org/10.3390/mi14111998 |
_version_ | 1785140619700600832 |
---|---|
author | Yan, Chenyu Liu, Manyu Shi, Guohua Fan, Jinyu Li, Yunyao Wu, Sujian Hu, Jinyuan |
author_facet | Yan, Chenyu Liu, Manyu Shi, Guohua Fan, Jinyu Li, Yunyao Wu, Sujian Hu, Jinyuan |
author_sort | Yan, Chenyu |
collection | PubMed |
description | This study presents an investigation focusing on the advancement of a robot designed for subretinal injections in the context of macular degeneration treatment. The technique of subretinal injection surgery stands as the most efficacious approach for the successful transplantation of stem cells into the retinal pigment epithelium layer. This particular procedure holds immense significance in advancing research and implementing therapeutic strategies involving retinal stem cell transplantation. The execution of artificial subretinal surgery poses considerable challenges which can be effectively addressed through the utilization of subretinal injection surgery robots. The development process involved a comprehensive modeling phase, integrating computer-aided design (CAD) and finite element analysis (FEA) techniques. These simulations facilitated iterative enhancements of the mechanical aspects pertaining to the robotic arm. Furthermore, MATLAB was employed to simulate and visualize the robot’s workspace, and independent verification was conducted to ascertain the range of motion for each degree of freedom. |
format | Online Article Text |
id | pubmed-10673425 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-106734252023-10-27 Design of a Subretinal Injection Robot Based on the RCM Mechanism Yan, Chenyu Liu, Manyu Shi, Guohua Fan, Jinyu Li, Yunyao Wu, Sujian Hu, Jinyuan Micromachines (Basel) Article This study presents an investigation focusing on the advancement of a robot designed for subretinal injections in the context of macular degeneration treatment. The technique of subretinal injection surgery stands as the most efficacious approach for the successful transplantation of stem cells into the retinal pigment epithelium layer. This particular procedure holds immense significance in advancing research and implementing therapeutic strategies involving retinal stem cell transplantation. The execution of artificial subretinal surgery poses considerable challenges which can be effectively addressed through the utilization of subretinal injection surgery robots. The development process involved a comprehensive modeling phase, integrating computer-aided design (CAD) and finite element analysis (FEA) techniques. These simulations facilitated iterative enhancements of the mechanical aspects pertaining to the robotic arm. Furthermore, MATLAB was employed to simulate and visualize the robot’s workspace, and independent verification was conducted to ascertain the range of motion for each degree of freedom. MDPI 2023-10-27 /pmc/articles/PMC10673425/ /pubmed/38004855 http://dx.doi.org/10.3390/mi14111998 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Yan, Chenyu Liu, Manyu Shi, Guohua Fan, Jinyu Li, Yunyao Wu, Sujian Hu, Jinyuan Design of a Subretinal Injection Robot Based on the RCM Mechanism |
title | Design of a Subretinal Injection Robot Based on the RCM Mechanism |
title_full | Design of a Subretinal Injection Robot Based on the RCM Mechanism |
title_fullStr | Design of a Subretinal Injection Robot Based on the RCM Mechanism |
title_full_unstemmed | Design of a Subretinal Injection Robot Based on the RCM Mechanism |
title_short | Design of a Subretinal Injection Robot Based on the RCM Mechanism |
title_sort | design of a subretinal injection robot based on the rcm mechanism |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10673425/ https://www.ncbi.nlm.nih.gov/pubmed/38004855 http://dx.doi.org/10.3390/mi14111998 |
work_keys_str_mv | AT yanchenyu designofasubretinalinjectionrobotbasedonthercmmechanism AT liumanyu designofasubretinalinjectionrobotbasedonthercmmechanism AT shiguohua designofasubretinalinjectionrobotbasedonthercmmechanism AT fanjinyu designofasubretinalinjectionrobotbasedonthercmmechanism AT liyunyao designofasubretinalinjectionrobotbasedonthercmmechanism AT wusujian designofasubretinalinjectionrobotbasedonthercmmechanism AT hujinyuan designofasubretinalinjectionrobotbasedonthercmmechanism |