Cargando…

Evaluation of a Manual Cytocentrifuge versus the Standard Automated Cytocentrifuge in the Analysis of Canine Cerebrospinal Fluid: A Case Series of 55 Dogs

SIMPLE SUMMARY: Veterinary cytology has become a cornerstone method for confirming initial clinical diagnosis, guiding early owner communication and therapeutic planning. Cytology is often acclaimed for the ease of obtaining samples, quick results and lower cost when compared with other diagnostic t...

Descripción completa

Detalles Bibliográficos
Autores principales: Fonte-Oliveira, Luísa, Pereira, André, Gregório, Hugo, Ribeiro, João, Correia-Gomes, Carla, Marcos, Ricardo, Santos, Marta
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10674567/
https://www.ncbi.nlm.nih.gov/pubmed/37999454
http://dx.doi.org/10.3390/vetsci10110631
_version_ 1785140858552582144
author Fonte-Oliveira, Luísa
Pereira, André
Gregório, Hugo
Ribeiro, João
Correia-Gomes, Carla
Marcos, Ricardo
Santos, Marta
author_facet Fonte-Oliveira, Luísa
Pereira, André
Gregório, Hugo
Ribeiro, João
Correia-Gomes, Carla
Marcos, Ricardo
Santos, Marta
author_sort Fonte-Oliveira, Luísa
collection PubMed
description SIMPLE SUMMARY: Veterinary cytology has become a cornerstone method for confirming initial clinical diagnosis, guiding early owner communication and therapeutic planning. Cytology is often acclaimed for the ease of obtaining samples, quick results and lower cost when compared with other diagnostic tests. The analysis of cerebrospinal fluid plays a central role in the management of neurologic patients. Cerebrospinal fluid is typically a low-protein, low-cell fluid that must be rapidly cytocentrifuged to obtain a good-quality cytologic slide, called a cytospin. Automated cytocentrifuges are relatively expensive pieces of equipment typically only available in veterinary and human diagnostic laboratories, but are not usually available for use in routine clinical practice. A low-cost manual cytocentrifuge is readily available and has been developed to obtain in-clinic cytospins of a variety of fluid samples. In this study, the use of a manual cytocentrifuge was validated for analysis of canine cerebrospinal fluids in routine clinical practice. ABSTRACT: Cytospins are important for evaluating fluids with very low cellularity such as cerebrospinal fluid (CSF). The aim of this study was to compare the CSF cytospin preparations obtained from automated and manual cytocentrifugation methods. A prospective case series was performed to analyze canine CSF samples using both centrifugation methods. The cytospins were processed within 30–60 min and prepared simultaneously in a conventional automated cytocentrifuge and in an in-house manual cytocentrifuge, using a fixed volume of CSF fluid. The cellularity, differential cell count and the proportion of cell artifacts (pseudopods and vacuolization) were blindly assessed in the cytospin preparations obtained using the two methods. The agreement and correlation between both methods were analyzed. There were 55 dogs enrolled (48 prospectively and 7 retrospectively) in the study. 38 dogs had normal total nucleated cell counts, while 17 had pleocytosis. Automated and manual cytocentrifugation had similar cell yields, and no significant differences in differential cell counts or the presence of artifacts existed between both methods. In cases with pleocytosis, the cytologic diagnosis obtained using each method was similar. Manual cytocentrifugation of CSF is a reliable and economic method designed for routine clinical practice. Its use reduces the specimen deterioration related to processing and analysis delays when samples are transported to external laboratories for evaluation.
format Online
Article
Text
id pubmed-10674567
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-106745672023-10-24 Evaluation of a Manual Cytocentrifuge versus the Standard Automated Cytocentrifuge in the Analysis of Canine Cerebrospinal Fluid: A Case Series of 55 Dogs Fonte-Oliveira, Luísa Pereira, André Gregório, Hugo Ribeiro, João Correia-Gomes, Carla Marcos, Ricardo Santos, Marta Vet Sci Article SIMPLE SUMMARY: Veterinary cytology has become a cornerstone method for confirming initial clinical diagnosis, guiding early owner communication and therapeutic planning. Cytology is often acclaimed for the ease of obtaining samples, quick results and lower cost when compared with other diagnostic tests. The analysis of cerebrospinal fluid plays a central role in the management of neurologic patients. Cerebrospinal fluid is typically a low-protein, low-cell fluid that must be rapidly cytocentrifuged to obtain a good-quality cytologic slide, called a cytospin. Automated cytocentrifuges are relatively expensive pieces of equipment typically only available in veterinary and human diagnostic laboratories, but are not usually available for use in routine clinical practice. A low-cost manual cytocentrifuge is readily available and has been developed to obtain in-clinic cytospins of a variety of fluid samples. In this study, the use of a manual cytocentrifuge was validated for analysis of canine cerebrospinal fluids in routine clinical practice. ABSTRACT: Cytospins are important for evaluating fluids with very low cellularity such as cerebrospinal fluid (CSF). The aim of this study was to compare the CSF cytospin preparations obtained from automated and manual cytocentrifugation methods. A prospective case series was performed to analyze canine CSF samples using both centrifugation methods. The cytospins were processed within 30–60 min and prepared simultaneously in a conventional automated cytocentrifuge and in an in-house manual cytocentrifuge, using a fixed volume of CSF fluid. The cellularity, differential cell count and the proportion of cell artifacts (pseudopods and vacuolization) were blindly assessed in the cytospin preparations obtained using the two methods. The agreement and correlation between both methods were analyzed. There were 55 dogs enrolled (48 prospectively and 7 retrospectively) in the study. 38 dogs had normal total nucleated cell counts, while 17 had pleocytosis. Automated and manual cytocentrifugation had similar cell yields, and no significant differences in differential cell counts or the presence of artifacts existed between both methods. In cases with pleocytosis, the cytologic diagnosis obtained using each method was similar. Manual cytocentrifugation of CSF is a reliable and economic method designed for routine clinical practice. Its use reduces the specimen deterioration related to processing and analysis delays when samples are transported to external laboratories for evaluation. MDPI 2023-10-24 /pmc/articles/PMC10674567/ /pubmed/37999454 http://dx.doi.org/10.3390/vetsci10110631 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Fonte-Oliveira, Luísa
Pereira, André
Gregório, Hugo
Ribeiro, João
Correia-Gomes, Carla
Marcos, Ricardo
Santos, Marta
Evaluation of a Manual Cytocentrifuge versus the Standard Automated Cytocentrifuge in the Analysis of Canine Cerebrospinal Fluid: A Case Series of 55 Dogs
title Evaluation of a Manual Cytocentrifuge versus the Standard Automated Cytocentrifuge in the Analysis of Canine Cerebrospinal Fluid: A Case Series of 55 Dogs
title_full Evaluation of a Manual Cytocentrifuge versus the Standard Automated Cytocentrifuge in the Analysis of Canine Cerebrospinal Fluid: A Case Series of 55 Dogs
title_fullStr Evaluation of a Manual Cytocentrifuge versus the Standard Automated Cytocentrifuge in the Analysis of Canine Cerebrospinal Fluid: A Case Series of 55 Dogs
title_full_unstemmed Evaluation of a Manual Cytocentrifuge versus the Standard Automated Cytocentrifuge in the Analysis of Canine Cerebrospinal Fluid: A Case Series of 55 Dogs
title_short Evaluation of a Manual Cytocentrifuge versus the Standard Automated Cytocentrifuge in the Analysis of Canine Cerebrospinal Fluid: A Case Series of 55 Dogs
title_sort evaluation of a manual cytocentrifuge versus the standard automated cytocentrifuge in the analysis of canine cerebrospinal fluid: a case series of 55 dogs
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10674567/
https://www.ncbi.nlm.nih.gov/pubmed/37999454
http://dx.doi.org/10.3390/vetsci10110631
work_keys_str_mv AT fonteoliveiraluisa evaluationofamanualcytocentrifugeversusthestandardautomatedcytocentrifugeintheanalysisofcaninecerebrospinalfluidacaseseriesof55dogs
AT pereiraandre evaluationofamanualcytocentrifugeversusthestandardautomatedcytocentrifugeintheanalysisofcaninecerebrospinalfluidacaseseriesof55dogs
AT gregoriohugo evaluationofamanualcytocentrifugeversusthestandardautomatedcytocentrifugeintheanalysisofcaninecerebrospinalfluidacaseseriesof55dogs
AT ribeirojoao evaluationofamanualcytocentrifugeversusthestandardautomatedcytocentrifugeintheanalysisofcaninecerebrospinalfluidacaseseriesof55dogs
AT correiagomescarla evaluationofamanualcytocentrifugeversusthestandardautomatedcytocentrifugeintheanalysisofcaninecerebrospinalfluidacaseseriesof55dogs
AT marcosricardo evaluationofamanualcytocentrifugeversusthestandardautomatedcytocentrifugeintheanalysisofcaninecerebrospinalfluidacaseseriesof55dogs
AT santosmarta evaluationofamanualcytocentrifugeversusthestandardautomatedcytocentrifugeintheanalysisofcaninecerebrospinalfluidacaseseriesof55dogs