Cargando…
Evaluation of Leading Smartwatches for the Detection of Hypoxemia: Comparison to Reference Oximeter
Although smartwatches are not considered medical devices, experimental validation of their accuracy in detecting hypoxemia is necessary due to their potential use in monitoring conditions manifested by a prolonged decrease in peripheral blood oxygen saturation (SpO(2)), such as chronic obstructive p...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10674783/ https://www.ncbi.nlm.nih.gov/pubmed/38005550 http://dx.doi.org/10.3390/s23229164 |
_version_ | 1785149749340405760 |
---|---|
author | Walzel, Simon Mikus, Radek Rafl-Huttova, Veronika Rozanek, Martin Bachman, Thomas E. Rafl, Jakub |
author_facet | Walzel, Simon Mikus, Radek Rafl-Huttova, Veronika Rozanek, Martin Bachman, Thomas E. Rafl, Jakub |
author_sort | Walzel, Simon |
collection | PubMed |
description | Although smartwatches are not considered medical devices, experimental validation of their accuracy in detecting hypoxemia is necessary due to their potential use in monitoring conditions manifested by a prolonged decrease in peripheral blood oxygen saturation (SpO(2)), such as chronic obstructive pulmonary disease, sleep apnea syndrome, and COVID-19, or at high altitudes, e.g., during sport climbing, where the use of finger-sensor-based pulse oximeters may be limited. The aim of this study was to experimentally compare the accuracy of SpO(2) measurement of popular smartwatches with a clinically used pulse oximeter according to the requirements of ISO 80601-2-61. Each of the 18 young and healthy participants underwent the experimental assessment three times in randomized order—wearing Apple Watch 8, Samsung Galaxy Watch 5, or Withings ScanWatch—resulting in 54 individual experimental assessments and complete datasets. The accuracy of the SpO(2) measurements was compared to that of the Radical-7 (Masimo Corporation, Irvine, CA, USA) during short-term hypoxemia induced by consecutive inhalation of three prepared gas mixtures with reduced oxygen concentrations (14%, 12%, and 10%). All three smartwatch models met the maximum acceptable root-mean-square deviation (≤4%) from the reference measurement at both normal oxygen levels and induced desaturation with SpO(2) less than 90%. Apple Watch 8 reached the highest reliability due to its lowest mean bias and root-mean-square deviation, highest Pearson correlation coefficient, and accuracy in detecting hypoxemia. Our findings support the use of smartwatches to reliably detect hypoxemia in situations where the use of standard finger pulse oximeters may be limited. |
format | Online Article Text |
id | pubmed-10674783 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-106747832023-11-14 Evaluation of Leading Smartwatches for the Detection of Hypoxemia: Comparison to Reference Oximeter Walzel, Simon Mikus, Radek Rafl-Huttova, Veronika Rozanek, Martin Bachman, Thomas E. Rafl, Jakub Sensors (Basel) Article Although smartwatches are not considered medical devices, experimental validation of their accuracy in detecting hypoxemia is necessary due to their potential use in monitoring conditions manifested by a prolonged decrease in peripheral blood oxygen saturation (SpO(2)), such as chronic obstructive pulmonary disease, sleep apnea syndrome, and COVID-19, or at high altitudes, e.g., during sport climbing, where the use of finger-sensor-based pulse oximeters may be limited. The aim of this study was to experimentally compare the accuracy of SpO(2) measurement of popular smartwatches with a clinically used pulse oximeter according to the requirements of ISO 80601-2-61. Each of the 18 young and healthy participants underwent the experimental assessment three times in randomized order—wearing Apple Watch 8, Samsung Galaxy Watch 5, or Withings ScanWatch—resulting in 54 individual experimental assessments and complete datasets. The accuracy of the SpO(2) measurements was compared to that of the Radical-7 (Masimo Corporation, Irvine, CA, USA) during short-term hypoxemia induced by consecutive inhalation of three prepared gas mixtures with reduced oxygen concentrations (14%, 12%, and 10%). All three smartwatch models met the maximum acceptable root-mean-square deviation (≤4%) from the reference measurement at both normal oxygen levels and induced desaturation with SpO(2) less than 90%. Apple Watch 8 reached the highest reliability due to its lowest mean bias and root-mean-square deviation, highest Pearson correlation coefficient, and accuracy in detecting hypoxemia. Our findings support the use of smartwatches to reliably detect hypoxemia in situations where the use of standard finger pulse oximeters may be limited. MDPI 2023-11-14 /pmc/articles/PMC10674783/ /pubmed/38005550 http://dx.doi.org/10.3390/s23229164 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Walzel, Simon Mikus, Radek Rafl-Huttova, Veronika Rozanek, Martin Bachman, Thomas E. Rafl, Jakub Evaluation of Leading Smartwatches for the Detection of Hypoxemia: Comparison to Reference Oximeter |
title | Evaluation of Leading Smartwatches for the Detection of Hypoxemia: Comparison to Reference Oximeter |
title_full | Evaluation of Leading Smartwatches for the Detection of Hypoxemia: Comparison to Reference Oximeter |
title_fullStr | Evaluation of Leading Smartwatches for the Detection of Hypoxemia: Comparison to Reference Oximeter |
title_full_unstemmed | Evaluation of Leading Smartwatches for the Detection of Hypoxemia: Comparison to Reference Oximeter |
title_short | Evaluation of Leading Smartwatches for the Detection of Hypoxemia: Comparison to Reference Oximeter |
title_sort | evaluation of leading smartwatches for the detection of hypoxemia: comparison to reference oximeter |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10674783/ https://www.ncbi.nlm.nih.gov/pubmed/38005550 http://dx.doi.org/10.3390/s23229164 |
work_keys_str_mv | AT walzelsimon evaluationofleadingsmartwatchesforthedetectionofhypoxemiacomparisontoreferenceoximeter AT mikusradek evaluationofleadingsmartwatchesforthedetectionofhypoxemiacomparisontoreferenceoximeter AT raflhuttovaveronika evaluationofleadingsmartwatchesforthedetectionofhypoxemiacomparisontoreferenceoximeter AT rozanekmartin evaluationofleadingsmartwatchesforthedetectionofhypoxemiacomparisontoreferenceoximeter AT bachmanthomase evaluationofleadingsmartwatchesforthedetectionofhypoxemiacomparisontoreferenceoximeter AT rafljakub evaluationofleadingsmartwatchesforthedetectionofhypoxemiacomparisontoreferenceoximeter |