Cargando…

Evaluation of Leading Smartwatches for the Detection of Hypoxemia: Comparison to Reference Oximeter

Although smartwatches are not considered medical devices, experimental validation of their accuracy in detecting hypoxemia is necessary due to their potential use in monitoring conditions manifested by a prolonged decrease in peripheral blood oxygen saturation (SpO(2)), such as chronic obstructive p...

Descripción completa

Detalles Bibliográficos
Autores principales: Walzel, Simon, Mikus, Radek, Rafl-Huttova, Veronika, Rozanek, Martin, Bachman, Thomas E., Rafl, Jakub
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10674783/
https://www.ncbi.nlm.nih.gov/pubmed/38005550
http://dx.doi.org/10.3390/s23229164
_version_ 1785149749340405760
author Walzel, Simon
Mikus, Radek
Rafl-Huttova, Veronika
Rozanek, Martin
Bachman, Thomas E.
Rafl, Jakub
author_facet Walzel, Simon
Mikus, Radek
Rafl-Huttova, Veronika
Rozanek, Martin
Bachman, Thomas E.
Rafl, Jakub
author_sort Walzel, Simon
collection PubMed
description Although smartwatches are not considered medical devices, experimental validation of their accuracy in detecting hypoxemia is necessary due to their potential use in monitoring conditions manifested by a prolonged decrease in peripheral blood oxygen saturation (SpO(2)), such as chronic obstructive pulmonary disease, sleep apnea syndrome, and COVID-19, or at high altitudes, e.g., during sport climbing, where the use of finger-sensor-based pulse oximeters may be limited. The aim of this study was to experimentally compare the accuracy of SpO(2) measurement of popular smartwatches with a clinically used pulse oximeter according to the requirements of ISO 80601-2-61. Each of the 18 young and healthy participants underwent the experimental assessment three times in randomized order—wearing Apple Watch 8, Samsung Galaxy Watch 5, or Withings ScanWatch—resulting in 54 individual experimental assessments and complete datasets. The accuracy of the SpO(2) measurements was compared to that of the Radical-7 (Masimo Corporation, Irvine, CA, USA) during short-term hypoxemia induced by consecutive inhalation of three prepared gas mixtures with reduced oxygen concentrations (14%, 12%, and 10%). All three smartwatch models met the maximum acceptable root-mean-square deviation (≤4%) from the reference measurement at both normal oxygen levels and induced desaturation with SpO(2) less than 90%. Apple Watch 8 reached the highest reliability due to its lowest mean bias and root-mean-square deviation, highest Pearson correlation coefficient, and accuracy in detecting hypoxemia. Our findings support the use of smartwatches to reliably detect hypoxemia in situations where the use of standard finger pulse oximeters may be limited.
format Online
Article
Text
id pubmed-10674783
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-106747832023-11-14 Evaluation of Leading Smartwatches for the Detection of Hypoxemia: Comparison to Reference Oximeter Walzel, Simon Mikus, Radek Rafl-Huttova, Veronika Rozanek, Martin Bachman, Thomas E. Rafl, Jakub Sensors (Basel) Article Although smartwatches are not considered medical devices, experimental validation of their accuracy in detecting hypoxemia is necessary due to their potential use in monitoring conditions manifested by a prolonged decrease in peripheral blood oxygen saturation (SpO(2)), such as chronic obstructive pulmonary disease, sleep apnea syndrome, and COVID-19, or at high altitudes, e.g., during sport climbing, where the use of finger-sensor-based pulse oximeters may be limited. The aim of this study was to experimentally compare the accuracy of SpO(2) measurement of popular smartwatches with a clinically used pulse oximeter according to the requirements of ISO 80601-2-61. Each of the 18 young and healthy participants underwent the experimental assessment three times in randomized order—wearing Apple Watch 8, Samsung Galaxy Watch 5, or Withings ScanWatch—resulting in 54 individual experimental assessments and complete datasets. The accuracy of the SpO(2) measurements was compared to that of the Radical-7 (Masimo Corporation, Irvine, CA, USA) during short-term hypoxemia induced by consecutive inhalation of three prepared gas mixtures with reduced oxygen concentrations (14%, 12%, and 10%). All three smartwatch models met the maximum acceptable root-mean-square deviation (≤4%) from the reference measurement at both normal oxygen levels and induced desaturation with SpO(2) less than 90%. Apple Watch 8 reached the highest reliability due to its lowest mean bias and root-mean-square deviation, highest Pearson correlation coefficient, and accuracy in detecting hypoxemia. Our findings support the use of smartwatches to reliably detect hypoxemia in situations where the use of standard finger pulse oximeters may be limited. MDPI 2023-11-14 /pmc/articles/PMC10674783/ /pubmed/38005550 http://dx.doi.org/10.3390/s23229164 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Walzel, Simon
Mikus, Radek
Rafl-Huttova, Veronika
Rozanek, Martin
Bachman, Thomas E.
Rafl, Jakub
Evaluation of Leading Smartwatches for the Detection of Hypoxemia: Comparison to Reference Oximeter
title Evaluation of Leading Smartwatches for the Detection of Hypoxemia: Comparison to Reference Oximeter
title_full Evaluation of Leading Smartwatches for the Detection of Hypoxemia: Comparison to Reference Oximeter
title_fullStr Evaluation of Leading Smartwatches for the Detection of Hypoxemia: Comparison to Reference Oximeter
title_full_unstemmed Evaluation of Leading Smartwatches for the Detection of Hypoxemia: Comparison to Reference Oximeter
title_short Evaluation of Leading Smartwatches for the Detection of Hypoxemia: Comparison to Reference Oximeter
title_sort evaluation of leading smartwatches for the detection of hypoxemia: comparison to reference oximeter
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10674783/
https://www.ncbi.nlm.nih.gov/pubmed/38005550
http://dx.doi.org/10.3390/s23229164
work_keys_str_mv AT walzelsimon evaluationofleadingsmartwatchesforthedetectionofhypoxemiacomparisontoreferenceoximeter
AT mikusradek evaluationofleadingsmartwatchesforthedetectionofhypoxemiacomparisontoreferenceoximeter
AT raflhuttovaveronika evaluationofleadingsmartwatchesforthedetectionofhypoxemiacomparisontoreferenceoximeter
AT rozanekmartin evaluationofleadingsmartwatchesforthedetectionofhypoxemiacomparisontoreferenceoximeter
AT bachmanthomase evaluationofleadingsmartwatchesforthedetectionofhypoxemiacomparisontoreferenceoximeter
AT rafljakub evaluationofleadingsmartwatchesforthedetectionofhypoxemiacomparisontoreferenceoximeter