Cargando…
Factory-Calibrated Continuous Glucose Monitoring Systems in Type 1 Diabetes: Accuracy during In-Clinic Exercise and Home Use
Continuous glucose monitors (CGMs) are valuable tools for improving glycemic control, yet their accuracy might be influenced by physical activity. This study sought to assess the accuracy of the three latest factory-calibrated CGM systems available in Europe at the time the study was conducted, both...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10675113/ https://www.ncbi.nlm.nih.gov/pubmed/38005642 http://dx.doi.org/10.3390/s23229256 |
_version_ | 1785149783242964992 |
---|---|
author | Lundemose, Sissel Banner Laugesen, Christian Ranjan, Ajenthen Gayathri Nørgaard, Kirsten |
author_facet | Lundemose, Sissel Banner Laugesen, Christian Ranjan, Ajenthen Gayathri Nørgaard, Kirsten |
author_sort | Lundemose, Sissel Banner |
collection | PubMed |
description | Continuous glucose monitors (CGMs) are valuable tools for improving glycemic control, yet their accuracy might be influenced by physical activity. This study sought to assess the accuracy of the three latest factory-calibrated CGM systems available in Europe at the time the study was conducted, both during aerobic exercise and in typical daily scenarios. The accuracy evaluation, based on metrics such as the median absolute relative difference (MARD) and point and rate error-grid analyses (PEGA and REGA), involved 13 adults with type 1 diabetes. Participants wore all sensors during a 1 h in-clinic exercise session followed by a subsequent 3-day home period, with blood glucose measurements serving as reference values in both contexts. During exercise, no statistically significant differences in MARD were observed (Dexcom G6: 12.6%, Guardian 4: 10.7%, and Freestyle Libre 2: 17.2%; p = 0.31), and similarly, no significant differences emerged in PEGA-zone-AB (100%, 100%, 96.8%; p = 0.37). Nevertheless, Freestyle Libre 2 showed comparatively diminished accuracy in estimating glucose trends during exercise (REGA-zone-AB: 100%, 93.0%, 73.3%; p = 0.0003). In the home environment, Freestyle Libre 2 exhibited a significantly higher MARD when compared to the other systems (10.2%, 11.9%, 16.7%, p = 0.02). Overall, Dexcom G6 and Guardian 4 demonstrated superior accuracy in both exercise and daily life scenarios compared to Freestyle Libre 2. |
format | Online Article Text |
id | pubmed-10675113 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-106751132023-11-18 Factory-Calibrated Continuous Glucose Monitoring Systems in Type 1 Diabetes: Accuracy during In-Clinic Exercise and Home Use Lundemose, Sissel Banner Laugesen, Christian Ranjan, Ajenthen Gayathri Nørgaard, Kirsten Sensors (Basel) Communication Continuous glucose monitors (CGMs) are valuable tools for improving glycemic control, yet their accuracy might be influenced by physical activity. This study sought to assess the accuracy of the three latest factory-calibrated CGM systems available in Europe at the time the study was conducted, both during aerobic exercise and in typical daily scenarios. The accuracy evaluation, based on metrics such as the median absolute relative difference (MARD) and point and rate error-grid analyses (PEGA and REGA), involved 13 adults with type 1 diabetes. Participants wore all sensors during a 1 h in-clinic exercise session followed by a subsequent 3-day home period, with blood glucose measurements serving as reference values in both contexts. During exercise, no statistically significant differences in MARD were observed (Dexcom G6: 12.6%, Guardian 4: 10.7%, and Freestyle Libre 2: 17.2%; p = 0.31), and similarly, no significant differences emerged in PEGA-zone-AB (100%, 100%, 96.8%; p = 0.37). Nevertheless, Freestyle Libre 2 showed comparatively diminished accuracy in estimating glucose trends during exercise (REGA-zone-AB: 100%, 93.0%, 73.3%; p = 0.0003). In the home environment, Freestyle Libre 2 exhibited a significantly higher MARD when compared to the other systems (10.2%, 11.9%, 16.7%, p = 0.02). Overall, Dexcom G6 and Guardian 4 demonstrated superior accuracy in both exercise and daily life scenarios compared to Freestyle Libre 2. MDPI 2023-11-18 /pmc/articles/PMC10675113/ /pubmed/38005642 http://dx.doi.org/10.3390/s23229256 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Communication Lundemose, Sissel Banner Laugesen, Christian Ranjan, Ajenthen Gayathri Nørgaard, Kirsten Factory-Calibrated Continuous Glucose Monitoring Systems in Type 1 Diabetes: Accuracy during In-Clinic Exercise and Home Use |
title | Factory-Calibrated Continuous Glucose Monitoring Systems in Type 1 Diabetes: Accuracy during In-Clinic Exercise and Home Use |
title_full | Factory-Calibrated Continuous Glucose Monitoring Systems in Type 1 Diabetes: Accuracy during In-Clinic Exercise and Home Use |
title_fullStr | Factory-Calibrated Continuous Glucose Monitoring Systems in Type 1 Diabetes: Accuracy during In-Clinic Exercise and Home Use |
title_full_unstemmed | Factory-Calibrated Continuous Glucose Monitoring Systems in Type 1 Diabetes: Accuracy during In-Clinic Exercise and Home Use |
title_short | Factory-Calibrated Continuous Glucose Monitoring Systems in Type 1 Diabetes: Accuracy during In-Clinic Exercise and Home Use |
title_sort | factory-calibrated continuous glucose monitoring systems in type 1 diabetes: accuracy during in-clinic exercise and home use |
topic | Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10675113/ https://www.ncbi.nlm.nih.gov/pubmed/38005642 http://dx.doi.org/10.3390/s23229256 |
work_keys_str_mv | AT lundemosesisselbanner factorycalibratedcontinuousglucosemonitoringsystemsintype1diabetesaccuracyduringinclinicexerciseandhomeuse AT laugesenchristian factorycalibratedcontinuousglucosemonitoringsystemsintype1diabetesaccuracyduringinclinicexerciseandhomeuse AT ranjanajenthengayathri factorycalibratedcontinuousglucosemonitoringsystemsintype1diabetesaccuracyduringinclinicexerciseandhomeuse AT nørgaardkirsten factorycalibratedcontinuousglucosemonitoringsystemsintype1diabetesaccuracyduringinclinicexerciseandhomeuse |