Cargando…
Design and Construction of the Optical Bench Interferometer for the Taiji Program
A kind of full-function two-sided optical bench interferometer (OBI) is designed to meet the practical requirements of the Taiji Program for space gravitational wave detection. The main optical paths are arranged on the A-side for transmission and interference, and other optical paths and electronic...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10675380/ https://www.ncbi.nlm.nih.gov/pubmed/38005529 http://dx.doi.org/10.3390/s23229141 |
_version_ | 1785149812722630656 |
---|---|
author | Tao, Wei Deng, Xiaoqin Diao, Yuqing Gao, Ruihong Qi, Keqi Wang, Shaoxin Luo, Ziren Sha, Wei Liu, Heshan |
author_facet | Tao, Wei Deng, Xiaoqin Diao, Yuqing Gao, Ruihong Qi, Keqi Wang, Shaoxin Luo, Ziren Sha, Wei Liu, Heshan |
author_sort | Tao, Wei |
collection | PubMed |
description | A kind of full-function two-sided optical bench interferometer (OBI) is designed to meet the practical requirements of the Taiji Program for space gravitational wave detection. The main optical paths are arranged on the A-side for transmission and interference, and other optical paths and electronic devices are placed on the B-side. According to the design scheme, we successfully constructed two OBIs by using hydrogen–oxygen catalytic stress-free bonding technology. When the OBI is installed and adjusted, the position and Angle error of the interference beam are controlled within 30 μm and 50 μrad through the self-designed precision mechanical clamping mechanism and beam position measuring device. The built OBI was placed on the vibration isolation platform in the vacuum tank for the stability test. The test results show that the noise of the OBI is less than 10 [Formula: see text] in the frequency band of 0.1 Hz to 1 Hz, which meets the noise budget requirements of the Taiji Pathfinder in the middle- and high-frequency band. |
format | Online Article Text |
id | pubmed-10675380 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-106753802023-11-13 Design and Construction of the Optical Bench Interferometer for the Taiji Program Tao, Wei Deng, Xiaoqin Diao, Yuqing Gao, Ruihong Qi, Keqi Wang, Shaoxin Luo, Ziren Sha, Wei Liu, Heshan Sensors (Basel) Article A kind of full-function two-sided optical bench interferometer (OBI) is designed to meet the practical requirements of the Taiji Program for space gravitational wave detection. The main optical paths are arranged on the A-side for transmission and interference, and other optical paths and electronic devices are placed on the B-side. According to the design scheme, we successfully constructed two OBIs by using hydrogen–oxygen catalytic stress-free bonding technology. When the OBI is installed and adjusted, the position and Angle error of the interference beam are controlled within 30 μm and 50 μrad through the self-designed precision mechanical clamping mechanism and beam position measuring device. The built OBI was placed on the vibration isolation platform in the vacuum tank for the stability test. The test results show that the noise of the OBI is less than 10 [Formula: see text] in the frequency band of 0.1 Hz to 1 Hz, which meets the noise budget requirements of the Taiji Pathfinder in the middle- and high-frequency band. MDPI 2023-11-13 /pmc/articles/PMC10675380/ /pubmed/38005529 http://dx.doi.org/10.3390/s23229141 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Tao, Wei Deng, Xiaoqin Diao, Yuqing Gao, Ruihong Qi, Keqi Wang, Shaoxin Luo, Ziren Sha, Wei Liu, Heshan Design and Construction of the Optical Bench Interferometer for the Taiji Program |
title | Design and Construction of the Optical Bench Interferometer for the Taiji Program |
title_full | Design and Construction of the Optical Bench Interferometer for the Taiji Program |
title_fullStr | Design and Construction of the Optical Bench Interferometer for the Taiji Program |
title_full_unstemmed | Design and Construction of the Optical Bench Interferometer for the Taiji Program |
title_short | Design and Construction of the Optical Bench Interferometer for the Taiji Program |
title_sort | design and construction of the optical bench interferometer for the taiji program |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10675380/ https://www.ncbi.nlm.nih.gov/pubmed/38005529 http://dx.doi.org/10.3390/s23229141 |
work_keys_str_mv | AT taowei designandconstructionoftheopticalbenchinterferometerforthetaijiprogram AT dengxiaoqin designandconstructionoftheopticalbenchinterferometerforthetaijiprogram AT diaoyuqing designandconstructionoftheopticalbenchinterferometerforthetaijiprogram AT gaoruihong designandconstructionoftheopticalbenchinterferometerforthetaijiprogram AT qikeqi designandconstructionoftheopticalbenchinterferometerforthetaijiprogram AT wangshaoxin designandconstructionoftheopticalbenchinterferometerforthetaijiprogram AT luoziren designandconstructionoftheopticalbenchinterferometerforthetaijiprogram AT shawei designandconstructionoftheopticalbenchinterferometerforthetaijiprogram AT liuheshan designandconstructionoftheopticalbenchinterferometerforthetaijiprogram |