Cargando…

The Use of Blocking Wires in Fibular Intramedullary Nailing of an Ankle Fracture with Hardware Failure: A Case Report

A 24-year-old male, with a body mass index (BMI) of 31.7 and a previous open reduction and internal fixation (ORIF) of the left ankle seven years ago, presented to the emergency department with a peri-implant, comminuted fibula fracture with broken hardware and syndesmotic injury. The nature of the...

Descripción completa

Detalles Bibliográficos
Autores principales: Acevedo, Daniel, Rizzo, Michael G, Constantinescu, David, Heng, Marilyn
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10676240/
https://www.ncbi.nlm.nih.gov/pubmed/38022253
http://dx.doi.org/10.7759/cureus.47737
Descripción
Sumario:A 24-year-old male, with a body mass index (BMI) of 31.7 and a previous open reduction and internal fixation (ORIF) of the left ankle seven years ago, presented to the emergency department with a peri-implant, comminuted fibula fracture with broken hardware and syndesmotic injury. The nature of the revision surgery made proper guidewire placement during fibular nailing difficult. Blocking wires assisted in ensuring proper guidewire placement. The patient was successfully managed with revision ORIF, fibular nailing, and syndesmotic fixation. Blocking wires are a helpful tool for achieving proper fracture alignment and stability during intramedullary nailing procedures and may be considered in fibular nailing situations.