Cargando…
The Use of Blocking Wires in Fibular Intramedullary Nailing of an Ankle Fracture with Hardware Failure: A Case Report
A 24-year-old male, with a body mass index (BMI) of 31.7 and a previous open reduction and internal fixation (ORIF) of the left ankle seven years ago, presented to the emergency department with a peri-implant, comminuted fibula fracture with broken hardware and syndesmotic injury. The nature of the...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cureus
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10676240/ https://www.ncbi.nlm.nih.gov/pubmed/38022253 http://dx.doi.org/10.7759/cureus.47737 |
Sumario: | A 24-year-old male, with a body mass index (BMI) of 31.7 and a previous open reduction and internal fixation (ORIF) of the left ankle seven years ago, presented to the emergency department with a peri-implant, comminuted fibula fracture with broken hardware and syndesmotic injury. The nature of the revision surgery made proper guidewire placement during fibular nailing difficult. Blocking wires assisted in ensuring proper guidewire placement. The patient was successfully managed with revision ORIF, fibular nailing, and syndesmotic fixation. Blocking wires are a helpful tool for achieving proper fracture alignment and stability during intramedullary nailing procedures and may be considered in fibular nailing situations. |
---|