Influence of different noninvasive oxygenation support devices on tidal volume
BACKGROUND: Multiple devices are available for noninvasive oxygenation support, including non-rebreather oxygen mask (O(2)-mask), high-flow oxygen through nasal cannula (HFNC), continuous positive airway pressure (CPAP), mask noninvasive ventilation (Mask-NIV) and helmet NIV (Helmet-NIV). As tidal v...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10676331/ https://www.ncbi.nlm.nih.gov/pubmed/38006434 http://dx.doi.org/10.1186/s13613-023-01200-2 |
_version_ | 1785149919886049280 |
---|---|
author | Haudebourg, Anne-Fleur Maraffi, Tommaso Tuffet, Samuel Le Corvoisier, Philippe Mekontso Dessap, Armand Carteaux, Guillaume |
author_facet | Haudebourg, Anne-Fleur Maraffi, Tommaso Tuffet, Samuel Le Corvoisier, Philippe Mekontso Dessap, Armand Carteaux, Guillaume |
author_sort | Haudebourg, Anne-Fleur |
collection | PubMed |
description | BACKGROUND: Multiple devices are available for noninvasive oxygenation support, including non-rebreather oxygen mask (O(2)-mask), high-flow oxygen through nasal cannula (HFNC), continuous positive airway pressure (CPAP), mask noninvasive ventilation (Mask-NIV) and helmet NIV (Helmet-NIV). As tidal volume is a key determinant of efficacy and safety during ventilatory support, we assessed whether it was influenced by the type of noninvasive oxygenation device. METHODS: A bench study using a manikin with a realistic face connected to a lung simulator was performed. Six conditions were assessed: no device, O(2)-mask, HFNC, CPAP, Mask-NIV and Helmet-NIV. Three respiratory mechanics were simulated (normal, obstructive, restrictive), at three simulated efforts (low, moderate, respiratory distress). Flow was recorded at the lung simulator inlet and mouth pressure into the manikin mouth. The same devices were evaluated on healthy volunteers with tidal volume assessed by electrical impedance tomography (EIT). RESULTS: Tidal volume was significantly influenced by oxygenation devices in bench model. As compared to O(2)-mask, HFNC and CPAP delivered significantly lower tidal volumes (440 ± 352 mL, 414 ± 333 mL and 377 ± 297 mL, respectively), while Mask-NIV or Helmet-NIV were associated with significantly higher tidal volumes (690 ± 321 mL and 652 ± 366 mL, respectively). Tidal volume was strongly correlated with the specific effect of each device on mouth pressure during inspiration: HFNC and CPAP were characterized by a negative PTPmouth (− 0.3 [− 0.8 to − 0.2] and − 0.7 [− 2.2 to − 0.5] cmH(2)O.sec/cycle, respectively), while Helmet-NIV and Mask-NIV were associated with a positive PTPmouth (4.5 [4.1–4.6] and 6.1 [5.9–7.1] cmH(2)O.sec/cycle, respectively). Tidal volume was also significantly influenced by oxygenation devices in healthy volunteers, with similar tidal volumes between O(2)-mask and CPAP (644 [571–764] and 648 [586–770] mL) but higher with HFNC, Mask-NIV and Helmet-NIV (819 [609–918], 1110 [661–1305] and 1086 [833–1243] mL). CONCLUSIONS: Tidal volume is significantly influenced by noninvasive oxygenation support devices, with a strong correlation with the pressure variation generated into the mouth during inspiration. NIV was associated with the highest tidal volumes and CPAP with the lowest ones. Clinical studies are needed to clarify the clinical implications of these effects. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13613-023-01200-2. |
format | Online Article Text |
id | pubmed-10676331 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-106763312023-11-25 Influence of different noninvasive oxygenation support devices on tidal volume Haudebourg, Anne-Fleur Maraffi, Tommaso Tuffet, Samuel Le Corvoisier, Philippe Mekontso Dessap, Armand Carteaux, Guillaume Ann Intensive Care Research BACKGROUND: Multiple devices are available for noninvasive oxygenation support, including non-rebreather oxygen mask (O(2)-mask), high-flow oxygen through nasal cannula (HFNC), continuous positive airway pressure (CPAP), mask noninvasive ventilation (Mask-NIV) and helmet NIV (Helmet-NIV). As tidal volume is a key determinant of efficacy and safety during ventilatory support, we assessed whether it was influenced by the type of noninvasive oxygenation device. METHODS: A bench study using a manikin with a realistic face connected to a lung simulator was performed. Six conditions were assessed: no device, O(2)-mask, HFNC, CPAP, Mask-NIV and Helmet-NIV. Three respiratory mechanics were simulated (normal, obstructive, restrictive), at three simulated efforts (low, moderate, respiratory distress). Flow was recorded at the lung simulator inlet and mouth pressure into the manikin mouth. The same devices were evaluated on healthy volunteers with tidal volume assessed by electrical impedance tomography (EIT). RESULTS: Tidal volume was significantly influenced by oxygenation devices in bench model. As compared to O(2)-mask, HFNC and CPAP delivered significantly lower tidal volumes (440 ± 352 mL, 414 ± 333 mL and 377 ± 297 mL, respectively), while Mask-NIV or Helmet-NIV were associated with significantly higher tidal volumes (690 ± 321 mL and 652 ± 366 mL, respectively). Tidal volume was strongly correlated with the specific effect of each device on mouth pressure during inspiration: HFNC and CPAP were characterized by a negative PTPmouth (− 0.3 [− 0.8 to − 0.2] and − 0.7 [− 2.2 to − 0.5] cmH(2)O.sec/cycle, respectively), while Helmet-NIV and Mask-NIV were associated with a positive PTPmouth (4.5 [4.1–4.6] and 6.1 [5.9–7.1] cmH(2)O.sec/cycle, respectively). Tidal volume was also significantly influenced by oxygenation devices in healthy volunteers, with similar tidal volumes between O(2)-mask and CPAP (644 [571–764] and 648 [586–770] mL) but higher with HFNC, Mask-NIV and Helmet-NIV (819 [609–918], 1110 [661–1305] and 1086 [833–1243] mL). CONCLUSIONS: Tidal volume is significantly influenced by noninvasive oxygenation support devices, with a strong correlation with the pressure variation generated into the mouth during inspiration. NIV was associated with the highest tidal volumes and CPAP with the lowest ones. Clinical studies are needed to clarify the clinical implications of these effects. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13613-023-01200-2. Springer International Publishing 2023-11-25 /pmc/articles/PMC10676331/ /pubmed/38006434 http://dx.doi.org/10.1186/s13613-023-01200-2 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Research Haudebourg, Anne-Fleur Maraffi, Tommaso Tuffet, Samuel Le Corvoisier, Philippe Mekontso Dessap, Armand Carteaux, Guillaume Influence of different noninvasive oxygenation support devices on tidal volume |
title | Influence of different noninvasive oxygenation support devices on tidal volume |
title_full | Influence of different noninvasive oxygenation support devices on tidal volume |
title_fullStr | Influence of different noninvasive oxygenation support devices on tidal volume |
title_full_unstemmed | Influence of different noninvasive oxygenation support devices on tidal volume |
title_short | Influence of different noninvasive oxygenation support devices on tidal volume |
title_sort | influence of different noninvasive oxygenation support devices on tidal volume |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10676331/ https://www.ncbi.nlm.nih.gov/pubmed/38006434 http://dx.doi.org/10.1186/s13613-023-01200-2 |
work_keys_str_mv | AT haudebourgannefleur influenceofdifferentnoninvasiveoxygenationsupportdevicesontidalvolume AT maraffitommaso influenceofdifferentnoninvasiveoxygenationsupportdevicesontidalvolume AT tuffetsamuel influenceofdifferentnoninvasiveoxygenationsupportdevicesontidalvolume AT lecorvoisierphilippe influenceofdifferentnoninvasiveoxygenationsupportdevicesontidalvolume AT mekontsodessaparmand influenceofdifferentnoninvasiveoxygenationsupportdevicesontidalvolume AT carteauxguillaume influenceofdifferentnoninvasiveoxygenationsupportdevicesontidalvolume |