Cargando…
A Prospective Study Comparing Dosimetry between Computed Tomography (CT) based Radiation Planning and Positron Emission Computed Tomography (PET-CT) based Radiation Planning in Treatment of Non-Metastatic Non Small Cell Lung Carcinoma
BACKGROUND: To evaluate dosimetry between CT based radiation planning and PET-CT based radiation planning. MATERIAL & METHODS: Histologically proven 40 cases of locally advanced non-small cell carcinoma of lung were accrued for the prospective study. Contrast enhanced planning CT images and PET...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
West Asia Organization for Cancer Prevention
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10676499/ https://www.ncbi.nlm.nih.gov/pubmed/37505789 http://dx.doi.org/10.31557/APJCP.2023.24.7.2543 |
_version_ | 1785141294816821248 |
---|---|
author | Mandal, Bidyut Basu, Abhishek Manna, Amitabha Mondal, Janmenjoy Ghosh, Debjit Chakraborty, Ipsita Biswas, Jayabrata Chakraborty, Addway |
author_facet | Mandal, Bidyut Basu, Abhishek Manna, Amitabha Mondal, Janmenjoy Ghosh, Debjit Chakraborty, Ipsita Biswas, Jayabrata Chakraborty, Addway |
author_sort | Mandal, Bidyut |
collection | PubMed |
description | BACKGROUND: To evaluate dosimetry between CT based radiation planning and PET-CT based radiation planning. MATERIAL & METHODS: Histologically proven 40 cases of locally advanced non-small cell carcinoma of lung were accrued for the prospective study. Contrast enhanced planning CT images and PET images were acquired. Target volume delineation, organs of interest & radiation planning were performed in Eclipse V 14.5 followed by dosimetric comparison among GTV, PTV and OARs. A p-value of <0.05 was considered significant. RESULTS: The mean of GTV were 141.18 ± 119.76 cc in CT and 115.54 ± 91.02 cc in PET-CT based and the difference was statistically significant (p=0.03). The mean of CTV were 313.91 ± 180.87 cc in CT and 260.81 ± 148.83 cc in PET-CT based and the difference was statistically significant (p=0.03). The contralateral lung mean dose was statistically very significant (p<0.01) among both the 3D-CRT plans which were 8.49 Gy in CECT based planning and 9.53 Gy in PET CT based planning. The heart mean dose was also statistically significant (p=0.03) among the plans which were 17.90 Gy in CECT based planning and 17.06 Gy in PET CT based planning. Mann-Whitney U test showed the CT based PTV D90 was 58.20 Gy vs 57.58 Gy in PET CT based planning (p=0.02). PTV V95 were also comparable in both of the plans (p=0.02). CONCLUSIONS: GTV measured using PET-CT, may be greater or lesser than the CECT-based GTV. PET-CT-based contouring is more accurate for identifying tumour margins and new lymph node volumes. |
format | Online Article Text |
id | pubmed-10676499 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | West Asia Organization for Cancer Prevention |
record_format | MEDLINE/PubMed |
spelling | pubmed-106764992023-03-01 A Prospective Study Comparing Dosimetry between Computed Tomography (CT) based Radiation Planning and Positron Emission Computed Tomography (PET-CT) based Radiation Planning in Treatment of Non-Metastatic Non Small Cell Lung Carcinoma Mandal, Bidyut Basu, Abhishek Manna, Amitabha Mondal, Janmenjoy Ghosh, Debjit Chakraborty, Ipsita Biswas, Jayabrata Chakraborty, Addway Asian Pac J Cancer Prev Research Article BACKGROUND: To evaluate dosimetry between CT based radiation planning and PET-CT based radiation planning. MATERIAL & METHODS: Histologically proven 40 cases of locally advanced non-small cell carcinoma of lung were accrued for the prospective study. Contrast enhanced planning CT images and PET images were acquired. Target volume delineation, organs of interest & radiation planning were performed in Eclipse V 14.5 followed by dosimetric comparison among GTV, PTV and OARs. A p-value of <0.05 was considered significant. RESULTS: The mean of GTV were 141.18 ± 119.76 cc in CT and 115.54 ± 91.02 cc in PET-CT based and the difference was statistically significant (p=0.03). The mean of CTV were 313.91 ± 180.87 cc in CT and 260.81 ± 148.83 cc in PET-CT based and the difference was statistically significant (p=0.03). The contralateral lung mean dose was statistically very significant (p<0.01) among both the 3D-CRT plans which were 8.49 Gy in CECT based planning and 9.53 Gy in PET CT based planning. The heart mean dose was also statistically significant (p=0.03) among the plans which were 17.90 Gy in CECT based planning and 17.06 Gy in PET CT based planning. Mann-Whitney U test showed the CT based PTV D90 was 58.20 Gy vs 57.58 Gy in PET CT based planning (p=0.02). PTV V95 were also comparable in both of the plans (p=0.02). CONCLUSIONS: GTV measured using PET-CT, may be greater or lesser than the CECT-based GTV. PET-CT-based contouring is more accurate for identifying tumour margins and new lymph node volumes. West Asia Organization for Cancer Prevention 2023 /pmc/articles/PMC10676499/ /pubmed/37505789 http://dx.doi.org/10.31557/APJCP.2023.24.7.2543 Text en https://creativecommons.org/licenses/by-nc/4.0/This work is licensed under a Creative Commons Attribution-Non Commercial 4.0 International License. (https://creativecommons.org/licenses/by-nc/4.0/) |
spellingShingle | Research Article Mandal, Bidyut Basu, Abhishek Manna, Amitabha Mondal, Janmenjoy Ghosh, Debjit Chakraborty, Ipsita Biswas, Jayabrata Chakraborty, Addway A Prospective Study Comparing Dosimetry between Computed Tomography (CT) based Radiation Planning and Positron Emission Computed Tomography (PET-CT) based Radiation Planning in Treatment of Non-Metastatic Non Small Cell Lung Carcinoma |
title | A Prospective Study Comparing Dosimetry between Computed Tomography (CT) based Radiation Planning and Positron Emission Computed Tomography (PET-CT) based Radiation Planning in Treatment of Non-Metastatic Non Small Cell Lung Carcinoma |
title_full | A Prospective Study Comparing Dosimetry between Computed Tomography (CT) based Radiation Planning and Positron Emission Computed Tomography (PET-CT) based Radiation Planning in Treatment of Non-Metastatic Non Small Cell Lung Carcinoma |
title_fullStr | A Prospective Study Comparing Dosimetry between Computed Tomography (CT) based Radiation Planning and Positron Emission Computed Tomography (PET-CT) based Radiation Planning in Treatment of Non-Metastatic Non Small Cell Lung Carcinoma |
title_full_unstemmed | A Prospective Study Comparing Dosimetry between Computed Tomography (CT) based Radiation Planning and Positron Emission Computed Tomography (PET-CT) based Radiation Planning in Treatment of Non-Metastatic Non Small Cell Lung Carcinoma |
title_short | A Prospective Study Comparing Dosimetry between Computed Tomography (CT) based Radiation Planning and Positron Emission Computed Tomography (PET-CT) based Radiation Planning in Treatment of Non-Metastatic Non Small Cell Lung Carcinoma |
title_sort | prospective study comparing dosimetry between computed tomography (ct) based radiation planning and positron emission computed tomography (pet-ct) based radiation planning in treatment of non-metastatic non small cell lung carcinoma |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10676499/ https://www.ncbi.nlm.nih.gov/pubmed/37505789 http://dx.doi.org/10.31557/APJCP.2023.24.7.2543 |
work_keys_str_mv | AT mandalbidyut aprospectivestudycomparingdosimetrybetweencomputedtomographyctbasedradiationplanningandpositronemissioncomputedtomographypetctbasedradiationplanningintreatmentofnonmetastaticnonsmallcelllungcarcinoma AT basuabhishek aprospectivestudycomparingdosimetrybetweencomputedtomographyctbasedradiationplanningandpositronemissioncomputedtomographypetctbasedradiationplanningintreatmentofnonmetastaticnonsmallcelllungcarcinoma AT mannaamitabha aprospectivestudycomparingdosimetrybetweencomputedtomographyctbasedradiationplanningandpositronemissioncomputedtomographypetctbasedradiationplanningintreatmentofnonmetastaticnonsmallcelllungcarcinoma AT mondaljanmenjoy aprospectivestudycomparingdosimetrybetweencomputedtomographyctbasedradiationplanningandpositronemissioncomputedtomographypetctbasedradiationplanningintreatmentofnonmetastaticnonsmallcelllungcarcinoma AT ghoshdebjit aprospectivestudycomparingdosimetrybetweencomputedtomographyctbasedradiationplanningandpositronemissioncomputedtomographypetctbasedradiationplanningintreatmentofnonmetastaticnonsmallcelllungcarcinoma AT chakrabortyipsita aprospectivestudycomparingdosimetrybetweencomputedtomographyctbasedradiationplanningandpositronemissioncomputedtomographypetctbasedradiationplanningintreatmentofnonmetastaticnonsmallcelllungcarcinoma AT biswasjayabrata aprospectivestudycomparingdosimetrybetweencomputedtomographyctbasedradiationplanningandpositronemissioncomputedtomographypetctbasedradiationplanningintreatmentofnonmetastaticnonsmallcelllungcarcinoma AT chakrabortyaddway aprospectivestudycomparingdosimetrybetweencomputedtomographyctbasedradiationplanningandpositronemissioncomputedtomographypetctbasedradiationplanningintreatmentofnonmetastaticnonsmallcelllungcarcinoma AT mandalbidyut prospectivestudycomparingdosimetrybetweencomputedtomographyctbasedradiationplanningandpositronemissioncomputedtomographypetctbasedradiationplanningintreatmentofnonmetastaticnonsmallcelllungcarcinoma AT basuabhishek prospectivestudycomparingdosimetrybetweencomputedtomographyctbasedradiationplanningandpositronemissioncomputedtomographypetctbasedradiationplanningintreatmentofnonmetastaticnonsmallcelllungcarcinoma AT mannaamitabha prospectivestudycomparingdosimetrybetweencomputedtomographyctbasedradiationplanningandpositronemissioncomputedtomographypetctbasedradiationplanningintreatmentofnonmetastaticnonsmallcelllungcarcinoma AT mondaljanmenjoy prospectivestudycomparingdosimetrybetweencomputedtomographyctbasedradiationplanningandpositronemissioncomputedtomographypetctbasedradiationplanningintreatmentofnonmetastaticnonsmallcelllungcarcinoma AT ghoshdebjit prospectivestudycomparingdosimetrybetweencomputedtomographyctbasedradiationplanningandpositronemissioncomputedtomographypetctbasedradiationplanningintreatmentofnonmetastaticnonsmallcelllungcarcinoma AT chakrabortyipsita prospectivestudycomparingdosimetrybetweencomputedtomographyctbasedradiationplanningandpositronemissioncomputedtomographypetctbasedradiationplanningintreatmentofnonmetastaticnonsmallcelllungcarcinoma AT biswasjayabrata prospectivestudycomparingdosimetrybetweencomputedtomographyctbasedradiationplanningandpositronemissioncomputedtomographypetctbasedradiationplanningintreatmentofnonmetastaticnonsmallcelllungcarcinoma AT chakrabortyaddway prospectivestudycomparingdosimetrybetweencomputedtomographyctbasedradiationplanningandpositronemissioncomputedtomographypetctbasedradiationplanningintreatmentofnonmetastaticnonsmallcelllungcarcinoma |