Cargando…

iOCT-guided simulated subretinal injections: a comparison between manual and robot-assisted techniques in an ex-vivo porcine model

The purpose of this study is to compare robot-assisted and manual subretinal injections in terms of successful subretinal blistering, reflux incidences and damage of the retinal pigment epithelium (RPE). Subretinal injection was simulated on 84 ex-vivo porcine eyes with half of the interventions bei...

Descripción completa

Detalles Bibliográficos
Autores principales: Maierhofer, Niklas A., Jablonka, Anne-Marie, Roodaki, Hessam, Nasseri, M. Ali, Eslami, Abouzar, Klaas, Julian, Lohmann, Chris P., Maier, Mathias, Zapp, Daniel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer London 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10678791/
https://www.ncbi.nlm.nih.gov/pubmed/37670151
http://dx.doi.org/10.1007/s11701-023-01699-4
_version_ 1785141964359860224
author Maierhofer, Niklas A.
Jablonka, Anne-Marie
Roodaki, Hessam
Nasseri, M. Ali
Eslami, Abouzar
Klaas, Julian
Lohmann, Chris P.
Maier, Mathias
Zapp, Daniel
author_facet Maierhofer, Niklas A.
Jablonka, Anne-Marie
Roodaki, Hessam
Nasseri, M. Ali
Eslami, Abouzar
Klaas, Julian
Lohmann, Chris P.
Maier, Mathias
Zapp, Daniel
author_sort Maierhofer, Niklas A.
collection PubMed
description The purpose of this study is to compare robot-assisted and manual subretinal injections in terms of successful subretinal blistering, reflux incidences and damage of the retinal pigment epithelium (RPE). Subretinal injection was simulated on 84 ex-vivo porcine eyes with half of the interventions being carried out manually and the other half by controlling a custom-built robot in a master–slave fashion. After pars plana vitrectomy (PPV), the retinal target spot was determined under a LUMERA 700 microscope with microscope-integrated intraoperative optical coherence tomography (iOCT) RESCAN 700 (Carl Zeiss Meditec, Germany). For injection, a 1 ml syringe filled with perfluorocarbon liquid (PFCL) was tipped with a 40-gauge metal cannula (Incyto Co., Ltd., South Korea). In one set of trials, the needle was attached to the robot’s end joint and maneuvered robotically to the retinal target site. In another set of trials, approaching the retina was performed manually. Intraretinal cannula-tip depth was monitored continuously via iOCT. At sufficient depth, PFCL was injected into the subretinal space. iOCT images and fundus video recordings were used to evaluate the surgical outcome. Robotic injections showed more often successful subretinal blistering (73.7% vs. 61.8%, p > 0.05) and a significantly lower incidence of reflux (23.7% vs. 58.8%, p < 0.01). Although larger tip depths were achieved in successful manual trials, RPE penetration occurred in 10.5% of robotic but in 26.5% of manual cases (p > 0.05). In conclusion, significantly less reflux incidences were achieved with the use of a robot. Furthermore, RPE penetrations occurred less and successful blistering more frequently when performing robotic surgery.
format Online
Article
Text
id pubmed-10678791
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer London
record_format MEDLINE/PubMed
spelling pubmed-106787912023-09-05 iOCT-guided simulated subretinal injections: a comparison between manual and robot-assisted techniques in an ex-vivo porcine model Maierhofer, Niklas A. Jablonka, Anne-Marie Roodaki, Hessam Nasseri, M. Ali Eslami, Abouzar Klaas, Julian Lohmann, Chris P. Maier, Mathias Zapp, Daniel J Robot Surg Original Article The purpose of this study is to compare robot-assisted and manual subretinal injections in terms of successful subretinal blistering, reflux incidences and damage of the retinal pigment epithelium (RPE). Subretinal injection was simulated on 84 ex-vivo porcine eyes with half of the interventions being carried out manually and the other half by controlling a custom-built robot in a master–slave fashion. After pars plana vitrectomy (PPV), the retinal target spot was determined under a LUMERA 700 microscope with microscope-integrated intraoperative optical coherence tomography (iOCT) RESCAN 700 (Carl Zeiss Meditec, Germany). For injection, a 1 ml syringe filled with perfluorocarbon liquid (PFCL) was tipped with a 40-gauge metal cannula (Incyto Co., Ltd., South Korea). In one set of trials, the needle was attached to the robot’s end joint and maneuvered robotically to the retinal target site. In another set of trials, approaching the retina was performed manually. Intraretinal cannula-tip depth was monitored continuously via iOCT. At sufficient depth, PFCL was injected into the subretinal space. iOCT images and fundus video recordings were used to evaluate the surgical outcome. Robotic injections showed more often successful subretinal blistering (73.7% vs. 61.8%, p > 0.05) and a significantly lower incidence of reflux (23.7% vs. 58.8%, p < 0.01). Although larger tip depths were achieved in successful manual trials, RPE penetration occurred in 10.5% of robotic but in 26.5% of manual cases (p > 0.05). In conclusion, significantly less reflux incidences were achieved with the use of a robot. Furthermore, RPE penetrations occurred less and successful blistering more frequently when performing robotic surgery. Springer London 2023-09-05 2023 /pmc/articles/PMC10678791/ /pubmed/37670151 http://dx.doi.org/10.1007/s11701-023-01699-4 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Maierhofer, Niklas A.
Jablonka, Anne-Marie
Roodaki, Hessam
Nasseri, M. Ali
Eslami, Abouzar
Klaas, Julian
Lohmann, Chris P.
Maier, Mathias
Zapp, Daniel
iOCT-guided simulated subretinal injections: a comparison between manual and robot-assisted techniques in an ex-vivo porcine model
title iOCT-guided simulated subretinal injections: a comparison between manual and robot-assisted techniques in an ex-vivo porcine model
title_full iOCT-guided simulated subretinal injections: a comparison between manual and robot-assisted techniques in an ex-vivo porcine model
title_fullStr iOCT-guided simulated subretinal injections: a comparison between manual and robot-assisted techniques in an ex-vivo porcine model
title_full_unstemmed iOCT-guided simulated subretinal injections: a comparison between manual and robot-assisted techniques in an ex-vivo porcine model
title_short iOCT-guided simulated subretinal injections: a comparison between manual and robot-assisted techniques in an ex-vivo porcine model
title_sort ioct-guided simulated subretinal injections: a comparison between manual and robot-assisted techniques in an ex-vivo porcine model
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10678791/
https://www.ncbi.nlm.nih.gov/pubmed/37670151
http://dx.doi.org/10.1007/s11701-023-01699-4
work_keys_str_mv AT maierhoferniklasa ioctguidedsimulatedsubretinalinjectionsacomparisonbetweenmanualandrobotassistedtechniquesinanexvivoporcinemodel
AT jablonkaannemarie ioctguidedsimulatedsubretinalinjectionsacomparisonbetweenmanualandrobotassistedtechniquesinanexvivoporcinemodel
AT roodakihessam ioctguidedsimulatedsubretinalinjectionsacomparisonbetweenmanualandrobotassistedtechniquesinanexvivoporcinemodel
AT nasserimali ioctguidedsimulatedsubretinalinjectionsacomparisonbetweenmanualandrobotassistedtechniquesinanexvivoporcinemodel
AT eslamiabouzar ioctguidedsimulatedsubretinalinjectionsacomparisonbetweenmanualandrobotassistedtechniquesinanexvivoporcinemodel
AT klaasjulian ioctguidedsimulatedsubretinalinjectionsacomparisonbetweenmanualandrobotassistedtechniquesinanexvivoporcinemodel
AT lohmannchrisp ioctguidedsimulatedsubretinalinjectionsacomparisonbetweenmanualandrobotassistedtechniquesinanexvivoporcinemodel
AT maiermathias ioctguidedsimulatedsubretinalinjectionsacomparisonbetweenmanualandrobotassistedtechniquesinanexvivoporcinemodel
AT zappdaniel ioctguidedsimulatedsubretinalinjectionsacomparisonbetweenmanualandrobotassistedtechniquesinanexvivoporcinemodel