2440. Central Line-Associated Bloodstream Infection Incidence Reduction Accompanies Initial-Specimen Diversion Device Adoption

BACKGROUND: Established lines are poor sites for sampling blood (frequently host to enterococci and Candida species) but peripheral venipuncture is an imperfect alternative as antiseptics struggle to eliminate deeply embedded microorganisms. State-of-the-art initial-specimen diversion device (ISDD)...

Descripción completa

Detalles Bibliográficos
Autor principal: Stroupe, Cody G
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10679020/
http://dx.doi.org/10.1093/ofid/ofad500.2059
_version_ 1785150494971265024
author Stroupe, Cody G
author_facet Stroupe, Cody G
author_sort Stroupe, Cody G
collection PubMed
description BACKGROUND: Established lines are poor sites for sampling blood (frequently host to enterococci and Candida species) but peripheral venipuncture is an imperfect alternative as antiseptics struggle to eliminate deeply embedded microorganisms. State-of-the-art initial-specimen diversion device (ISDD) use can facilitate near-zero blood culture contamination rates, but impact on central line-associated bloodstream infection (CLABSI) incidence is unclear. METHODS: Intervention took place within a Joint Commission-accredited, 200-bed, acute-care community hospital serving nine Southeastern United States counties toward the objective of reduced CLABSI reporting. From September 2021 through March 2023, ISDD use augmented all peripheral venipuncture sample collection for adult patient blood culture. CLABSI reporting and the associated National Healthcare Safety Network (NHSN) standardized infection ratio (SIR) data for the 18-month intervention period was compared to the preceding 18-month period. RESULTS: For the 18 months prior to ISDD use, 6.5 CLABSIs were predicted and 17 CLABSIs were reported. For the 18 months during which ISDD use augmented standard procedure, 5.5 CLABSIs were predicted and 3 CLABSIs were reported. ISDD use accompanied an 80% reduction in SIR, from 2.6 to 0.5. [Figure: see text] CONCLUSION: The study period coincided with the COVID-19 pandemic, a nationwide struggle with considerable quality control shortcomings observed in this space that, by juxtaposition, reinforce the strengths of the intervention. SIRs are the primary means of tracking healthcare-associated infection trends, and financial penalties follow performances failing to meet predictions. As CLABSI reporting throughout the intervention period was dramatically below NHSN prediction, the author concludes that ISDDs have standard-of-care potential and encourages further study in the interest of antimicrobial stewardship and quality control. DISCLOSURES: All Authors: No reported disclosures
format Online
Article
Text
id pubmed-10679020
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-106790202023-11-27 2440. Central Line-Associated Bloodstream Infection Incidence Reduction Accompanies Initial-Specimen Diversion Device Adoption Stroupe, Cody G Open Forum Infect Dis Abstract BACKGROUND: Established lines are poor sites for sampling blood (frequently host to enterococci and Candida species) but peripheral venipuncture is an imperfect alternative as antiseptics struggle to eliminate deeply embedded microorganisms. State-of-the-art initial-specimen diversion device (ISDD) use can facilitate near-zero blood culture contamination rates, but impact on central line-associated bloodstream infection (CLABSI) incidence is unclear. METHODS: Intervention took place within a Joint Commission-accredited, 200-bed, acute-care community hospital serving nine Southeastern United States counties toward the objective of reduced CLABSI reporting. From September 2021 through March 2023, ISDD use augmented all peripheral venipuncture sample collection for adult patient blood culture. CLABSI reporting and the associated National Healthcare Safety Network (NHSN) standardized infection ratio (SIR) data for the 18-month intervention period was compared to the preceding 18-month period. RESULTS: For the 18 months prior to ISDD use, 6.5 CLABSIs were predicted and 17 CLABSIs were reported. For the 18 months during which ISDD use augmented standard procedure, 5.5 CLABSIs were predicted and 3 CLABSIs were reported. ISDD use accompanied an 80% reduction in SIR, from 2.6 to 0.5. [Figure: see text] CONCLUSION: The study period coincided with the COVID-19 pandemic, a nationwide struggle with considerable quality control shortcomings observed in this space that, by juxtaposition, reinforce the strengths of the intervention. SIRs are the primary means of tracking healthcare-associated infection trends, and financial penalties follow performances failing to meet predictions. As CLABSI reporting throughout the intervention period was dramatically below NHSN prediction, the author concludes that ISDDs have standard-of-care potential and encourages further study in the interest of antimicrobial stewardship and quality control. DISCLOSURES: All Authors: No reported disclosures Oxford University Press 2023-11-27 /pmc/articles/PMC10679020/ http://dx.doi.org/10.1093/ofid/ofad500.2059 Text en © The Author(s) 2023. Published by Oxford University Press on behalf of Infectious Diseases Society of America. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Abstract
Stroupe, Cody G
2440. Central Line-Associated Bloodstream Infection Incidence Reduction Accompanies Initial-Specimen Diversion Device Adoption
title 2440. Central Line-Associated Bloodstream Infection Incidence Reduction Accompanies Initial-Specimen Diversion Device Adoption
title_full 2440. Central Line-Associated Bloodstream Infection Incidence Reduction Accompanies Initial-Specimen Diversion Device Adoption
title_fullStr 2440. Central Line-Associated Bloodstream Infection Incidence Reduction Accompanies Initial-Specimen Diversion Device Adoption
title_full_unstemmed 2440. Central Line-Associated Bloodstream Infection Incidence Reduction Accompanies Initial-Specimen Diversion Device Adoption
title_short 2440. Central Line-Associated Bloodstream Infection Incidence Reduction Accompanies Initial-Specimen Diversion Device Adoption
title_sort 2440. central line-associated bloodstream infection incidence reduction accompanies initial-specimen diversion device adoption
topic Abstract
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10679020/
http://dx.doi.org/10.1093/ofid/ofad500.2059
work_keys_str_mv AT stroupecodyg 2440centrallineassociatedbloodstreaminfectionincidencereductionaccompaniesinitialspecimendiversiondeviceadoption