Cargando…

Intermediate-term Outcomes Following a Case Series of Reoperations for Medtronic Freestyle Stentless Aortic Valves

BACKGROUND: Data are limited on long-term outcomes in patients who have undergone a reoperation following failure of a stentless aortic valve. METHODS: Between 2006 and 2016, a retrospective analysis was performed on 24 patients who underwent open aortic valve replacement surgery for a failed stentl...

Descripción completa

Detalles Bibliográficos
Autores principales: Bittira, Bindu, Shurrab, Mohammed, Santi, Stacey, Grieve, Sarah, MacDonald, Derek J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10679463/
https://www.ncbi.nlm.nih.gov/pubmed/38020335
http://dx.doi.org/10.1016/j.cjco.2023.08.008
_version_ 1785142156971737088
author Bittira, Bindu
Shurrab, Mohammed
Santi, Stacey
Grieve, Sarah
MacDonald, Derek J.
author_facet Bittira, Bindu
Shurrab, Mohammed
Santi, Stacey
Grieve, Sarah
MacDonald, Derek J.
author_sort Bittira, Bindu
collection PubMed
description BACKGROUND: Data are limited on long-term outcomes in patients who have undergone a reoperation following failure of a stentless aortic valve. METHODS: Between 2006 and 2016, a retrospective analysis was performed on 24 patients who underwent open aortic valve replacement surgery for a failed stentless aortic valve prosthesis at Health Sciences North, Sudbury, Ontario, Canada. The primary outcome was a low mortality rate from cardiac-related deaths after 5 years. RESULTS: All patients underwent insertion of a Medtronic Freestyle bioprosthesis (Minneapolis, MN) implanted using the modified subcoronary technique for their initial operation. The interval from the first operation to the stentless redo surgery ranged from 6 to 13 years. Aortic valve reoperation was performed for structural valve deterioration in 96% (n = 23) of the cases. Reoperations involved a removal of the stented valve leaflets and standard aortic valve replacement within the stentless casing in 20% (n = 5) of the cases, with the remaining cases requiring complete removal of the stentless prosthesis and aortic valve replacement. In those in whom a complete removal of the stentless valve was possible (n = 19), no disruption of the native aortic root occurred, with a 0% rate of conversion to a Bentall procedure. No intraoperative mortality occurred. The 30-day and 10-year operative mortality rates were 4% and 16%, respectively. CONCLUSIONS: Redo surgery for failing stentless valves can be done with relatively low risk and with acceptable long-term outcomes without resorting to root-replacement techniques.
format Online
Article
Text
id pubmed-10679463
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-106794632023-08-29 Intermediate-term Outcomes Following a Case Series of Reoperations for Medtronic Freestyle Stentless Aortic Valves Bittira, Bindu Shurrab, Mohammed Santi, Stacey Grieve, Sarah MacDonald, Derek J. CJC Open Original Article BACKGROUND: Data are limited on long-term outcomes in patients who have undergone a reoperation following failure of a stentless aortic valve. METHODS: Between 2006 and 2016, a retrospective analysis was performed on 24 patients who underwent open aortic valve replacement surgery for a failed stentless aortic valve prosthesis at Health Sciences North, Sudbury, Ontario, Canada. The primary outcome was a low mortality rate from cardiac-related deaths after 5 years. RESULTS: All patients underwent insertion of a Medtronic Freestyle bioprosthesis (Minneapolis, MN) implanted using the modified subcoronary technique for their initial operation. The interval from the first operation to the stentless redo surgery ranged from 6 to 13 years. Aortic valve reoperation was performed for structural valve deterioration in 96% (n = 23) of the cases. Reoperations involved a removal of the stented valve leaflets and standard aortic valve replacement within the stentless casing in 20% (n = 5) of the cases, with the remaining cases requiring complete removal of the stentless prosthesis and aortic valve replacement. In those in whom a complete removal of the stentless valve was possible (n = 19), no disruption of the native aortic root occurred, with a 0% rate of conversion to a Bentall procedure. No intraoperative mortality occurred. The 30-day and 10-year operative mortality rates were 4% and 16%, respectively. CONCLUSIONS: Redo surgery for failing stentless valves can be done with relatively low risk and with acceptable long-term outcomes without resorting to root-replacement techniques. Elsevier 2023-08-29 /pmc/articles/PMC10679463/ /pubmed/38020335 http://dx.doi.org/10.1016/j.cjco.2023.08.008 Text en © 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Bittira, Bindu
Shurrab, Mohammed
Santi, Stacey
Grieve, Sarah
MacDonald, Derek J.
Intermediate-term Outcomes Following a Case Series of Reoperations for Medtronic Freestyle Stentless Aortic Valves
title Intermediate-term Outcomes Following a Case Series of Reoperations for Medtronic Freestyle Stentless Aortic Valves
title_full Intermediate-term Outcomes Following a Case Series of Reoperations for Medtronic Freestyle Stentless Aortic Valves
title_fullStr Intermediate-term Outcomes Following a Case Series of Reoperations for Medtronic Freestyle Stentless Aortic Valves
title_full_unstemmed Intermediate-term Outcomes Following a Case Series of Reoperations for Medtronic Freestyle Stentless Aortic Valves
title_short Intermediate-term Outcomes Following a Case Series of Reoperations for Medtronic Freestyle Stentless Aortic Valves
title_sort intermediate-term outcomes following a case series of reoperations for medtronic freestyle stentless aortic valves
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10679463/
https://www.ncbi.nlm.nih.gov/pubmed/38020335
http://dx.doi.org/10.1016/j.cjco.2023.08.008
work_keys_str_mv AT bittirabindu intermediatetermoutcomesfollowingacaseseriesofreoperationsformedtronicfreestylestentlessaorticvalves
AT shurrabmohammed intermediatetermoutcomesfollowingacaseseriesofreoperationsformedtronicfreestylestentlessaorticvalves
AT santistacey intermediatetermoutcomesfollowingacaseseriesofreoperationsformedtronicfreestylestentlessaorticvalves
AT grievesarah intermediatetermoutcomesfollowingacaseseriesofreoperationsformedtronicfreestylestentlessaorticvalves
AT macdonaldderekj intermediatetermoutcomesfollowingacaseseriesofreoperationsformedtronicfreestylestentlessaorticvalves