Cargando…

Efficacy and safety of transcatheter arterial embolization for hemodynamically unstable bleeding after percutaneous transthoracic needle biopsy

PURPOSE: To evaluate the safety and efficacy of transcatheter arterial embolization (TAE) in controlling hemodynamically unstable bleeding following a percutaneous transthoracic needle biopsy (PTNB). METHODS: A total of seven patients (four men and three women; mean age, 62 ± 12 years) who received...

Descripción completa

Detalles Bibliográficos
Autores principales: Yeon, Su Kyeong, Ahn, Yura, Shin, Ji Hoon, Oh, Sang Young, Kim, Gun Ha
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Galenos Publishing 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10679561/
https://www.ncbi.nlm.nih.gov/pubmed/37650514
http://dx.doi.org/10.4274/dir.2023.232253
_version_ 1785150604715229184
author Yeon, Su Kyeong
Ahn, Yura
Shin, Ji Hoon
Oh, Sang Young
Kim, Gun Ha
author_facet Yeon, Su Kyeong
Ahn, Yura
Shin, Ji Hoon
Oh, Sang Young
Kim, Gun Ha
author_sort Yeon, Su Kyeong
collection PubMed
description PURPOSE: To evaluate the safety and efficacy of transcatheter arterial embolization (TAE) in controlling hemodynamically unstable bleeding following a percutaneous transthoracic needle biopsy (PTNB). METHODS: A total of seven patients (four men and three women; mean age, 62 ± 12 years) who received TAE for post-PTNB bleeding between May 2007 and March 2022 were included. The observed types of bleeding were hemothorax (n = 3), hemoptysis (n = 2), and a combination of both (n = 2). In patients with active bleeding, the technical success of TAE was defined as superselective embolization of the target artery with no active bleeding visible on post-TAE angiography. Clinical success was defined as sustained cessation of bleeding without hemodynamic instability, requirement of repeat TAE, or the need for post-TAE hemostatic surgery during the initial admission. The metrics analyzed included technical and clinical success rates, complications, and 30-day mortality. RESULTS: All seven patients achieved technical success, with a clinical success rate of 86% (6/7). Six patients were discharged alive, while one patient died of respiratory failure accompanied by hemothorax 19 days post-biopsy. The angiographic findings associated with bleeding were contrast media extravasation or pseudoaneurysm (n = 3) and vascular hypertrophy with tortuosity (n = 2). The implicated bleeding arteries included the intercostal artery (n = 2), bronchial artery (n = 2), and internal thoracic artery (n = 1). In two cases, no clear bleeding foci were identified; nonetheless, prophylactic embolization was performed on the right intercostal artery (n = 1) and right intercostobronchial trunk (n = 1). The embolic agents utilized included microcoils (n = 1), gelatin sponge particles (n = 2), polyvinyl alcohol (PVA) with gelatin sponge particles (n = 1), PVA with microcoils (n = 1), microcoils with gelatin sponge particles (n = 1), and microcoils with n-butyl-2-cyanoacrylate and gelatin sponge particles (n = 1). The 30-day mortality rate was 14% (1/7). No ischemic complications related to TAE were observed. CONCLUSION: The study suggests that TAE is safe and effective for controlling hemodynamically unstable bleeding following a PTNB.
format Online
Article
Text
id pubmed-10679561
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Galenos Publishing
record_format MEDLINE/PubMed
spelling pubmed-106795612023-12-05 Efficacy and safety of transcatheter arterial embolization for hemodynamically unstable bleeding after percutaneous transthoracic needle biopsy Yeon, Su Kyeong Ahn, Yura Shin, Ji Hoon Oh, Sang Young Kim, Gun Ha Diagn Interv Radiol Interventional Radiology - Original Article PURPOSE: To evaluate the safety and efficacy of transcatheter arterial embolization (TAE) in controlling hemodynamically unstable bleeding following a percutaneous transthoracic needle biopsy (PTNB). METHODS: A total of seven patients (four men and three women; mean age, 62 ± 12 years) who received TAE for post-PTNB bleeding between May 2007 and March 2022 were included. The observed types of bleeding were hemothorax (n = 3), hemoptysis (n = 2), and a combination of both (n = 2). In patients with active bleeding, the technical success of TAE was defined as superselective embolization of the target artery with no active bleeding visible on post-TAE angiography. Clinical success was defined as sustained cessation of bleeding without hemodynamic instability, requirement of repeat TAE, or the need for post-TAE hemostatic surgery during the initial admission. The metrics analyzed included technical and clinical success rates, complications, and 30-day mortality. RESULTS: All seven patients achieved technical success, with a clinical success rate of 86% (6/7). Six patients were discharged alive, while one patient died of respiratory failure accompanied by hemothorax 19 days post-biopsy. The angiographic findings associated with bleeding were contrast media extravasation or pseudoaneurysm (n = 3) and vascular hypertrophy with tortuosity (n = 2). The implicated bleeding arteries included the intercostal artery (n = 2), bronchial artery (n = 2), and internal thoracic artery (n = 1). In two cases, no clear bleeding foci were identified; nonetheless, prophylactic embolization was performed on the right intercostal artery (n = 1) and right intercostobronchial trunk (n = 1). The embolic agents utilized included microcoils (n = 1), gelatin sponge particles (n = 2), polyvinyl alcohol (PVA) with gelatin sponge particles (n = 1), PVA with microcoils (n = 1), microcoils with gelatin sponge particles (n = 1), and microcoils with n-butyl-2-cyanoacrylate and gelatin sponge particles (n = 1). The 30-day mortality rate was 14% (1/7). No ischemic complications related to TAE were observed. CONCLUSION: The study suggests that TAE is safe and effective for controlling hemodynamically unstable bleeding following a PTNB. Galenos Publishing 2023-11-07 /pmc/articles/PMC10679561/ /pubmed/37650514 http://dx.doi.org/10.4274/dir.2023.232253 Text en © Copyright 2023 by Turkish Society of Radiology | Diagnostic and Interventional Radiology, published by Galenos Publishing House. https://creativecommons.org/licenses/by-nc/4.0/Content of this journal is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License. (https://creativecommons.org/licenses/by-nc/4.0/)
spellingShingle Interventional Radiology - Original Article
Yeon, Su Kyeong
Ahn, Yura
Shin, Ji Hoon
Oh, Sang Young
Kim, Gun Ha
Efficacy and safety of transcatheter arterial embolization for hemodynamically unstable bleeding after percutaneous transthoracic needle biopsy
title Efficacy and safety of transcatheter arterial embolization for hemodynamically unstable bleeding after percutaneous transthoracic needle biopsy
title_full Efficacy and safety of transcatheter arterial embolization for hemodynamically unstable bleeding after percutaneous transthoracic needle biopsy
title_fullStr Efficacy and safety of transcatheter arterial embolization for hemodynamically unstable bleeding after percutaneous transthoracic needle biopsy
title_full_unstemmed Efficacy and safety of transcatheter arterial embolization for hemodynamically unstable bleeding after percutaneous transthoracic needle biopsy
title_short Efficacy and safety of transcatheter arterial embolization for hemodynamically unstable bleeding after percutaneous transthoracic needle biopsy
title_sort efficacy and safety of transcatheter arterial embolization for hemodynamically unstable bleeding after percutaneous transthoracic needle biopsy
topic Interventional Radiology - Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10679561/
https://www.ncbi.nlm.nih.gov/pubmed/37650514
http://dx.doi.org/10.4274/dir.2023.232253
work_keys_str_mv AT yeonsukyeong efficacyandsafetyoftranscatheterarterialembolizationforhemodynamicallyunstablebleedingafterpercutaneoustransthoracicneedlebiopsy
AT ahnyura efficacyandsafetyoftranscatheterarterialembolizationforhemodynamicallyunstablebleedingafterpercutaneoustransthoracicneedlebiopsy
AT shinjihoon efficacyandsafetyoftranscatheterarterialembolizationforhemodynamicallyunstablebleedingafterpercutaneoustransthoracicneedlebiopsy
AT ohsangyoung efficacyandsafetyoftranscatheterarterialembolizationforhemodynamicallyunstablebleedingafterpercutaneoustransthoracicneedlebiopsy
AT kimgunha efficacyandsafetyoftranscatheterarterialembolizationforhemodynamicallyunstablebleedingafterpercutaneoustransthoracicneedlebiopsy