Cargando…

Electrophoretic deposition of magnesium oxide coating on micro-arc oxidized titanium for antibacterial activity and biocompatibility

Titanium (Ti) dental implants face risks of early failure due to bacterial adhesion and biofilm formation. It is thus necessary to endow the implant surface with antibacterial ability. In this study, magnesium oxide (MgO) coatings were prepared on Ti by combining micro-arc oxidation (MAO) and electr...

Descripción completa

Detalles Bibliográficos
Autores principales: Fan, Xinli, Du, Jiaheng, Li, Yaohua, Duan, Ke, Liu, Gangli
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10680288/
https://www.ncbi.nlm.nih.gov/pubmed/38012792
http://dx.doi.org/10.1186/s13018-023-04390-4
_version_ 1785150695051100160
author Fan, Xinli
Du, Jiaheng
Li, Yaohua
Duan, Ke
Liu, Gangli
author_facet Fan, Xinli
Du, Jiaheng
Li, Yaohua
Duan, Ke
Liu, Gangli
author_sort Fan, Xinli
collection PubMed
description Titanium (Ti) dental implants face risks of early failure due to bacterial adhesion and biofilm formation. It is thus necessary to endow the implant surface with antibacterial ability. In this study, magnesium oxide (MgO) coatings were prepared on Ti by combining micro-arc oxidation (MAO) and electrophoretic deposition (EPD). The MgO nanoparticles homogeneously deposited on the microporous surface of MAO-treated Ti, yielding increasing coverage with the EPD time increased to 15 to 60 s. After co-culture with Porphyromonas gingivalis (P. gingivalis) for 24 h, 48 h, and 72 h, the coatings produced antibacterial rates of 4–53 %, 27–71 %, and 39–79 %, respectively, in a dose-dependent manner. Overall, EPD for 45 s offered satisfactory comprehensive performance, with an antibacterial rate 79 % at 72 h and a relative cell viability 85 % at 5 d. Electron and fluorescence microscopies revealed that, both the density of adherent bacterial adhesion on the surface and the proportion of viable bacteria decreased with the EPD time. The morphology of cells on the surface of each group was intact and there was no significant difference among the groups. These results show that, the MgO coating deposited on MAO-treated Ti by EPD had reasonably good in vitro antibacterial properties and cytocompatibility.
format Online
Article
Text
id pubmed-10680288
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-106802882023-11-27 Electrophoretic deposition of magnesium oxide coating on micro-arc oxidized titanium for antibacterial activity and biocompatibility Fan, Xinli Du, Jiaheng Li, Yaohua Duan, Ke Liu, Gangli J Orthop Surg Res Research Article Titanium (Ti) dental implants face risks of early failure due to bacterial adhesion and biofilm formation. It is thus necessary to endow the implant surface with antibacterial ability. In this study, magnesium oxide (MgO) coatings were prepared on Ti by combining micro-arc oxidation (MAO) and electrophoretic deposition (EPD). The MgO nanoparticles homogeneously deposited on the microporous surface of MAO-treated Ti, yielding increasing coverage with the EPD time increased to 15 to 60 s. After co-culture with Porphyromonas gingivalis (P. gingivalis) for 24 h, 48 h, and 72 h, the coatings produced antibacterial rates of 4–53 %, 27–71 %, and 39–79 %, respectively, in a dose-dependent manner. Overall, EPD for 45 s offered satisfactory comprehensive performance, with an antibacterial rate 79 % at 72 h and a relative cell viability 85 % at 5 d. Electron and fluorescence microscopies revealed that, both the density of adherent bacterial adhesion on the surface and the proportion of viable bacteria decreased with the EPD time. The morphology of cells on the surface of each group was intact and there was no significant difference among the groups. These results show that, the MgO coating deposited on MAO-treated Ti by EPD had reasonably good in vitro antibacterial properties and cytocompatibility. BioMed Central 2023-11-27 /pmc/articles/PMC10680288/ /pubmed/38012792 http://dx.doi.org/10.1186/s13018-023-04390-4 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Fan, Xinli
Du, Jiaheng
Li, Yaohua
Duan, Ke
Liu, Gangli
Electrophoretic deposition of magnesium oxide coating on micro-arc oxidized titanium for antibacterial activity and biocompatibility
title Electrophoretic deposition of magnesium oxide coating on micro-arc oxidized titanium for antibacterial activity and biocompatibility
title_full Electrophoretic deposition of magnesium oxide coating on micro-arc oxidized titanium for antibacterial activity and biocompatibility
title_fullStr Electrophoretic deposition of magnesium oxide coating on micro-arc oxidized titanium for antibacterial activity and biocompatibility
title_full_unstemmed Electrophoretic deposition of magnesium oxide coating on micro-arc oxidized titanium for antibacterial activity and biocompatibility
title_short Electrophoretic deposition of magnesium oxide coating on micro-arc oxidized titanium for antibacterial activity and biocompatibility
title_sort electrophoretic deposition of magnesium oxide coating on micro-arc oxidized titanium for antibacterial activity and biocompatibility
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10680288/
https://www.ncbi.nlm.nih.gov/pubmed/38012792
http://dx.doi.org/10.1186/s13018-023-04390-4
work_keys_str_mv AT fanxinli electrophoreticdepositionofmagnesiumoxidecoatingonmicroarcoxidizedtitaniumforantibacterialactivityandbiocompatibility
AT dujiaheng electrophoreticdepositionofmagnesiumoxidecoatingonmicroarcoxidizedtitaniumforantibacterialactivityandbiocompatibility
AT liyaohua electrophoreticdepositionofmagnesiumoxidecoatingonmicroarcoxidizedtitaniumforantibacterialactivityandbiocompatibility
AT duanke electrophoreticdepositionofmagnesiumoxidecoatingonmicroarcoxidizedtitaniumforantibacterialactivityandbiocompatibility
AT liugangli electrophoreticdepositionofmagnesiumoxidecoatingonmicroarcoxidizedtitaniumforantibacterialactivityandbiocompatibility