Cargando…
Electrophoretic deposition of magnesium oxide coating on micro-arc oxidized titanium for antibacterial activity and biocompatibility
Titanium (Ti) dental implants face risks of early failure due to bacterial adhesion and biofilm formation. It is thus necessary to endow the implant surface with antibacterial ability. In this study, magnesium oxide (MgO) coatings were prepared on Ti by combining micro-arc oxidation (MAO) and electr...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10680288/ https://www.ncbi.nlm.nih.gov/pubmed/38012792 http://dx.doi.org/10.1186/s13018-023-04390-4 |
_version_ | 1785150695051100160 |
---|---|
author | Fan, Xinli Du, Jiaheng Li, Yaohua Duan, Ke Liu, Gangli |
author_facet | Fan, Xinli Du, Jiaheng Li, Yaohua Duan, Ke Liu, Gangli |
author_sort | Fan, Xinli |
collection | PubMed |
description | Titanium (Ti) dental implants face risks of early failure due to bacterial adhesion and biofilm formation. It is thus necessary to endow the implant surface with antibacterial ability. In this study, magnesium oxide (MgO) coatings were prepared on Ti by combining micro-arc oxidation (MAO) and electrophoretic deposition (EPD). The MgO nanoparticles homogeneously deposited on the microporous surface of MAO-treated Ti, yielding increasing coverage with the EPD time increased to 15 to 60 s. After co-culture with Porphyromonas gingivalis (P. gingivalis) for 24 h, 48 h, and 72 h, the coatings produced antibacterial rates of 4–53 %, 27–71 %, and 39–79 %, respectively, in a dose-dependent manner. Overall, EPD for 45 s offered satisfactory comprehensive performance, with an antibacterial rate 79 % at 72 h and a relative cell viability 85 % at 5 d. Electron and fluorescence microscopies revealed that, both the density of adherent bacterial adhesion on the surface and the proportion of viable bacteria decreased with the EPD time. The morphology of cells on the surface of each group was intact and there was no significant difference among the groups. These results show that, the MgO coating deposited on MAO-treated Ti by EPD had reasonably good in vitro antibacterial properties and cytocompatibility. |
format | Online Article Text |
id | pubmed-10680288 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-106802882023-11-27 Electrophoretic deposition of magnesium oxide coating on micro-arc oxidized titanium for antibacterial activity and biocompatibility Fan, Xinli Du, Jiaheng Li, Yaohua Duan, Ke Liu, Gangli J Orthop Surg Res Research Article Titanium (Ti) dental implants face risks of early failure due to bacterial adhesion and biofilm formation. It is thus necessary to endow the implant surface with antibacterial ability. In this study, magnesium oxide (MgO) coatings were prepared on Ti by combining micro-arc oxidation (MAO) and electrophoretic deposition (EPD). The MgO nanoparticles homogeneously deposited on the microporous surface of MAO-treated Ti, yielding increasing coverage with the EPD time increased to 15 to 60 s. After co-culture with Porphyromonas gingivalis (P. gingivalis) for 24 h, 48 h, and 72 h, the coatings produced antibacterial rates of 4–53 %, 27–71 %, and 39–79 %, respectively, in a dose-dependent manner. Overall, EPD for 45 s offered satisfactory comprehensive performance, with an antibacterial rate 79 % at 72 h and a relative cell viability 85 % at 5 d. Electron and fluorescence microscopies revealed that, both the density of adherent bacterial adhesion on the surface and the proportion of viable bacteria decreased with the EPD time. The morphology of cells on the surface of each group was intact and there was no significant difference among the groups. These results show that, the MgO coating deposited on MAO-treated Ti by EPD had reasonably good in vitro antibacterial properties and cytocompatibility. BioMed Central 2023-11-27 /pmc/articles/PMC10680288/ /pubmed/38012792 http://dx.doi.org/10.1186/s13018-023-04390-4 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Fan, Xinli Du, Jiaheng Li, Yaohua Duan, Ke Liu, Gangli Electrophoretic deposition of magnesium oxide coating on micro-arc oxidized titanium for antibacterial activity and biocompatibility |
title | Electrophoretic deposition of magnesium oxide coating on micro-arc oxidized titanium for antibacterial activity and biocompatibility |
title_full | Electrophoretic deposition of magnesium oxide coating on micro-arc oxidized titanium for antibacterial activity and biocompatibility |
title_fullStr | Electrophoretic deposition of magnesium oxide coating on micro-arc oxidized titanium for antibacterial activity and biocompatibility |
title_full_unstemmed | Electrophoretic deposition of magnesium oxide coating on micro-arc oxidized titanium for antibacterial activity and biocompatibility |
title_short | Electrophoretic deposition of magnesium oxide coating on micro-arc oxidized titanium for antibacterial activity and biocompatibility |
title_sort | electrophoretic deposition of magnesium oxide coating on micro-arc oxidized titanium for antibacterial activity and biocompatibility |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10680288/ https://www.ncbi.nlm.nih.gov/pubmed/38012792 http://dx.doi.org/10.1186/s13018-023-04390-4 |
work_keys_str_mv | AT fanxinli electrophoreticdepositionofmagnesiumoxidecoatingonmicroarcoxidizedtitaniumforantibacterialactivityandbiocompatibility AT dujiaheng electrophoreticdepositionofmagnesiumoxidecoatingonmicroarcoxidizedtitaniumforantibacterialactivityandbiocompatibility AT liyaohua electrophoreticdepositionofmagnesiumoxidecoatingonmicroarcoxidizedtitaniumforantibacterialactivityandbiocompatibility AT duanke electrophoreticdepositionofmagnesiumoxidecoatingonmicroarcoxidizedtitaniumforantibacterialactivityandbiocompatibility AT liugangli electrophoreticdepositionofmagnesiumoxidecoatingonmicroarcoxidizedtitaniumforantibacterialactivityandbiocompatibility |