Optomechanical assessment of photorefractive corneal cross-linking via optical coherence elastography

Purpose: Corneal cross-linking (CXL) has recently been used with promising results to positively affect corneal refractive power in the treatment of hyperopia and mild myopia. However, understanding and predicting the optomechanical changes induced by this procedure are challenging. Methods: We appl...

Descripción completa

Detalles Bibliográficos
Autores principales: Frigelli, Matteo, Büchler, Philippe, Kling, Sabine
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10680454/
https://www.ncbi.nlm.nih.gov/pubmed/38026898
http://dx.doi.org/10.3389/fbioe.2023.1272097
_version_ 1785142391041163264
author Frigelli, Matteo
Büchler, Philippe
Kling, Sabine
author_facet Frigelli, Matteo
Büchler, Philippe
Kling, Sabine
author_sort Frigelli, Matteo
collection PubMed
description Purpose: Corneal cross-linking (CXL) has recently been used with promising results to positively affect corneal refractive power in the treatment of hyperopia and mild myopia. However, understanding and predicting the optomechanical changes induced by this procedure are challenging. Methods: We applied ambient pressure modulation based optical coherence elastography (OCE) to quantify the refractive and mechanical effects of patterned CXL and their relationship to energy delivered during the treatment on porcine corneas. Three different patterned treatments were performed, designed according to Zernike polynomial functions (circle, astigmatism, coma). In addition, three different irradiation protocols were analyzed: standard Dresden CXL (fluence of 5.4 J/cm(2)), accelerated CXL (fluence of 5.4 J/cm(2)), and high-fluence CXL (fluence of 16.2 J/cm(2)). The axial strain distribution in the stroma induced by ocular inflation (Δp = 30 mmHg) was quantified, maps of the anterior sagittal curvature were constructed and cylindrical refraction was assessed. Results: Thirty minutes after CXL, there was a statistically significant increase in axial strain amplitude (p < 0.050) and a reduction in sagittal curvature (p < 0.050) in the regions treated with all irradiation patterns compared to the non-irradiated ones. Thirty-6 hours later, the non-irradiated regions showed compressive strains, while the axial strain in the CXL-treated regions was close to zero, and the reduction in sagittal curvature observed 30 minutes after the treatment was maintained. The Dresden CXL and accelerated CXL produced comparable amounts of stiffening and refractive changes (p = 0.856), while high-fluence CXL produced the strongest response in terms of axial strain (6.9‰ ± 1.9‰) and refractive correction (3.4 ± 0.9 D). Tripling the energy administered during CXL resulted in a 2.4-fold increase in the resulting refractive correction. Conclusion: OCE showed that refractive changes and alterations in corneal biomechanics are directly related. A patient-specific selection of both, the administered UV fluence and the irradiation pattern during CXL is promising to allow customized photorefractive corrections in the future.
format Online
Article
Text
id pubmed-10680454
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-106804542023-01-01 Optomechanical assessment of photorefractive corneal cross-linking via optical coherence elastography Frigelli, Matteo Büchler, Philippe Kling, Sabine Front Bioeng Biotechnol Bioengineering and Biotechnology Purpose: Corneal cross-linking (CXL) has recently been used with promising results to positively affect corneal refractive power in the treatment of hyperopia and mild myopia. However, understanding and predicting the optomechanical changes induced by this procedure are challenging. Methods: We applied ambient pressure modulation based optical coherence elastography (OCE) to quantify the refractive and mechanical effects of patterned CXL and their relationship to energy delivered during the treatment on porcine corneas. Three different patterned treatments were performed, designed according to Zernike polynomial functions (circle, astigmatism, coma). In addition, three different irradiation protocols were analyzed: standard Dresden CXL (fluence of 5.4 J/cm(2)), accelerated CXL (fluence of 5.4 J/cm(2)), and high-fluence CXL (fluence of 16.2 J/cm(2)). The axial strain distribution in the stroma induced by ocular inflation (Δp = 30 mmHg) was quantified, maps of the anterior sagittal curvature were constructed and cylindrical refraction was assessed. Results: Thirty minutes after CXL, there was a statistically significant increase in axial strain amplitude (p < 0.050) and a reduction in sagittal curvature (p < 0.050) in the regions treated with all irradiation patterns compared to the non-irradiated ones. Thirty-6 hours later, the non-irradiated regions showed compressive strains, while the axial strain in the CXL-treated regions was close to zero, and the reduction in sagittal curvature observed 30 minutes after the treatment was maintained. The Dresden CXL and accelerated CXL produced comparable amounts of stiffening and refractive changes (p = 0.856), while high-fluence CXL produced the strongest response in terms of axial strain (6.9‰ ± 1.9‰) and refractive correction (3.4 ± 0.9 D). Tripling the energy administered during CXL resulted in a 2.4-fold increase in the resulting refractive correction. Conclusion: OCE showed that refractive changes and alterations in corneal biomechanics are directly related. A patient-specific selection of both, the administered UV fluence and the irradiation pattern during CXL is promising to allow customized photorefractive corrections in the future. Frontiers Media S.A. 2023-11-13 /pmc/articles/PMC10680454/ /pubmed/38026898 http://dx.doi.org/10.3389/fbioe.2023.1272097 Text en Copyright © 2023 Frigelli, Büchler and Kling. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Bioengineering and Biotechnology
Frigelli, Matteo
Büchler, Philippe
Kling, Sabine
Optomechanical assessment of photorefractive corneal cross-linking via optical coherence elastography
title Optomechanical assessment of photorefractive corneal cross-linking via optical coherence elastography
title_full Optomechanical assessment of photorefractive corneal cross-linking via optical coherence elastography
title_fullStr Optomechanical assessment of photorefractive corneal cross-linking via optical coherence elastography
title_full_unstemmed Optomechanical assessment of photorefractive corneal cross-linking via optical coherence elastography
title_short Optomechanical assessment of photorefractive corneal cross-linking via optical coherence elastography
title_sort optomechanical assessment of photorefractive corneal cross-linking via optical coherence elastography
topic Bioengineering and Biotechnology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10680454/
https://www.ncbi.nlm.nih.gov/pubmed/38026898
http://dx.doi.org/10.3389/fbioe.2023.1272097
work_keys_str_mv AT frigellimatteo optomechanicalassessmentofphotorefractivecornealcrosslinkingviaopticalcoherenceelastography
AT buchlerphilippe optomechanicalassessmentofphotorefractivecornealcrosslinkingviaopticalcoherenceelastography
AT klingsabine optomechanicalassessmentofphotorefractivecornealcrosslinkingviaopticalcoherenceelastography