Cargando…

Computed Tomography-guided Drainage with Modified Trocar Technique Using a Drainaway Drainage Kit

PURPOSE: Image-guided percutaneous drainage for abscesses is known as a safe and effective treatment. The computed tomography-guided percutaneous drainage kit Drainaway (SB Kawasumi Co., Ltd.), developed on the basis of a modified trocar method, has made it possible to complete the procedure only un...

Descripción completa

Detalles Bibliográficos
Autores principales: Togawa, Koji, Nakatsuka, Seishi, Tsukada, Jitsuro, Ito, Nobutake, Yamamoto, Yosuke, Kogo, Togo, Yoshikawa, Hiroki, Misu, Manabu, Tamura, Masashi, Soga, Shigeyoshi, Inoue, Masanori, Yashiro, Hideki, Kurata, Tadayoshi, Okada, Masahiro, Jinzaki, Masahiro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Japanese Society of Interventional Radiology 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10681752/
https://www.ncbi.nlm.nih.gov/pubmed/38020458
http://dx.doi.org/10.22575/interventionalradiology.2022-0027
_version_ 1785142612348370944
author Togawa, Koji
Nakatsuka, Seishi
Tsukada, Jitsuro
Ito, Nobutake
Yamamoto, Yosuke
Kogo, Togo
Yoshikawa, Hiroki
Misu, Manabu
Tamura, Masashi
Soga, Shigeyoshi
Inoue, Masanori
Yashiro, Hideki
Kurata, Tadayoshi
Okada, Masahiro
Jinzaki, Masahiro
author_facet Togawa, Koji
Nakatsuka, Seishi
Tsukada, Jitsuro
Ito, Nobutake
Yamamoto, Yosuke
Kogo, Togo
Yoshikawa, Hiroki
Misu, Manabu
Tamura, Masashi
Soga, Shigeyoshi
Inoue, Masanori
Yashiro, Hideki
Kurata, Tadayoshi
Okada, Masahiro
Jinzaki, Masahiro
author_sort Togawa, Koji
collection PubMed
description PURPOSE: Image-guided percutaneous drainage for abscesses is known as a safe and effective treatment. The computed tomography-guided percutaneous drainage kit Drainaway (SB Kawasumi Co., Ltd.), developed on the basis of a modified trocar method, has made it possible to complete the procedure only under computed tomography guidance without radiographic fluoroscopy. This study investigated the feasibility and safety of Drainaway for abscess drainage. MATERIAL AND METHODS: In this retrospective observational study, 28 procedures in 27 patients (18 men and 9 women; age 67.0 ± 12.3 years) who underwent computed tomography-guided drainage using Drainaway between March and December 2021 at seven affiliated hospitals were analyzed. Patients with symptomatic, puncturable on computed tomography and refractory abscesses were included. Technical success (successful drainage with computed tomography alone), primary clinical success (successful drainage with Drainaway alone), secondary clinical success (avoidance of surgery), and complications were evaluated. RESULTS: The sites of the abscesses were the intraperitoneal, retroperitoneal, and thoracic cavities in 19, 5, and 2 patients, respectively, and subcutaneous tissue in 1 patient. The mean size of the abscesses was 7.1 ± 3.4 cm. The technical success rate was 96.4%; the ligament of the puncture route could not be penetrated in one case. The primary clinical success rate was 77.8%, whereas the secondary clinical success rate of catheter upsizing or replacement was 96.3%. Complications included one case of biliary pleurisy that required drainage. CONCLUSIONS: Drainaway is a useful device that allows abscess drainage using only computed tomography guidance without radiographic fluoroscopy.
format Online
Article
Text
id pubmed-10681752
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher The Japanese Society of Interventional Radiology
record_format MEDLINE/PubMed
spelling pubmed-106817522023-08-11 Computed Tomography-guided Drainage with Modified Trocar Technique Using a Drainaway Drainage Kit Togawa, Koji Nakatsuka, Seishi Tsukada, Jitsuro Ito, Nobutake Yamamoto, Yosuke Kogo, Togo Yoshikawa, Hiroki Misu, Manabu Tamura, Masashi Soga, Shigeyoshi Inoue, Masanori Yashiro, Hideki Kurata, Tadayoshi Okada, Masahiro Jinzaki, Masahiro Interv Radiol (Higashimatsuyama) Original Research PURPOSE: Image-guided percutaneous drainage for abscesses is known as a safe and effective treatment. The computed tomography-guided percutaneous drainage kit Drainaway (SB Kawasumi Co., Ltd.), developed on the basis of a modified trocar method, has made it possible to complete the procedure only under computed tomography guidance without radiographic fluoroscopy. This study investigated the feasibility and safety of Drainaway for abscess drainage. MATERIAL AND METHODS: In this retrospective observational study, 28 procedures in 27 patients (18 men and 9 women; age 67.0 ± 12.3 years) who underwent computed tomography-guided drainage using Drainaway between March and December 2021 at seven affiliated hospitals were analyzed. Patients with symptomatic, puncturable on computed tomography and refractory abscesses were included. Technical success (successful drainage with computed tomography alone), primary clinical success (successful drainage with Drainaway alone), secondary clinical success (avoidance of surgery), and complications were evaluated. RESULTS: The sites of the abscesses were the intraperitoneal, retroperitoneal, and thoracic cavities in 19, 5, and 2 patients, respectively, and subcutaneous tissue in 1 patient. The mean size of the abscesses was 7.1 ± 3.4 cm. The technical success rate was 96.4%; the ligament of the puncture route could not be penetrated in one case. The primary clinical success rate was 77.8%, whereas the secondary clinical success rate of catheter upsizing or replacement was 96.3%. Complications included one case of biliary pleurisy that required drainage. CONCLUSIONS: Drainaway is a useful device that allows abscess drainage using only computed tomography guidance without radiographic fluoroscopy. The Japanese Society of Interventional Radiology 2023-08-11 /pmc/articles/PMC10681752/ /pubmed/38020458 http://dx.doi.org/10.22575/interventionalradiology.2022-0027 Text en © 2023 Japanese Society of Interventional Radiology https://creativecommons.org/licenses/by-nc/4.0/Interventional Radiology is an Open Access journal distributed under the Creative Commons Attribution-NonCommercial 4.0 International License. To view the details of this license, please visit (https://creativecommons.org/licenses/by-nc/4.0/).
spellingShingle Original Research
Togawa, Koji
Nakatsuka, Seishi
Tsukada, Jitsuro
Ito, Nobutake
Yamamoto, Yosuke
Kogo, Togo
Yoshikawa, Hiroki
Misu, Manabu
Tamura, Masashi
Soga, Shigeyoshi
Inoue, Masanori
Yashiro, Hideki
Kurata, Tadayoshi
Okada, Masahiro
Jinzaki, Masahiro
Computed Tomography-guided Drainage with Modified Trocar Technique Using a Drainaway Drainage Kit
title Computed Tomography-guided Drainage with Modified Trocar Technique Using a Drainaway Drainage Kit
title_full Computed Tomography-guided Drainage with Modified Trocar Technique Using a Drainaway Drainage Kit
title_fullStr Computed Tomography-guided Drainage with Modified Trocar Technique Using a Drainaway Drainage Kit
title_full_unstemmed Computed Tomography-guided Drainage with Modified Trocar Technique Using a Drainaway Drainage Kit
title_short Computed Tomography-guided Drainage with Modified Trocar Technique Using a Drainaway Drainage Kit
title_sort computed tomography-guided drainage with modified trocar technique using a drainaway drainage kit
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10681752/
https://www.ncbi.nlm.nih.gov/pubmed/38020458
http://dx.doi.org/10.22575/interventionalradiology.2022-0027
work_keys_str_mv AT togawakoji computedtomographyguideddrainagewithmodifiedtrocartechniqueusingadrainawaydrainagekit
AT nakatsukaseishi computedtomographyguideddrainagewithmodifiedtrocartechniqueusingadrainawaydrainagekit
AT tsukadajitsuro computedtomographyguideddrainagewithmodifiedtrocartechniqueusingadrainawaydrainagekit
AT itonobutake computedtomographyguideddrainagewithmodifiedtrocartechniqueusingadrainawaydrainagekit
AT yamamotoyosuke computedtomographyguideddrainagewithmodifiedtrocartechniqueusingadrainawaydrainagekit
AT kogotogo computedtomographyguideddrainagewithmodifiedtrocartechniqueusingadrainawaydrainagekit
AT yoshikawahiroki computedtomographyguideddrainagewithmodifiedtrocartechniqueusingadrainawaydrainagekit
AT misumanabu computedtomographyguideddrainagewithmodifiedtrocartechniqueusingadrainawaydrainagekit
AT tamuramasashi computedtomographyguideddrainagewithmodifiedtrocartechniqueusingadrainawaydrainagekit
AT sogashigeyoshi computedtomographyguideddrainagewithmodifiedtrocartechniqueusingadrainawaydrainagekit
AT inouemasanori computedtomographyguideddrainagewithmodifiedtrocartechniqueusingadrainawaydrainagekit
AT yashirohideki computedtomographyguideddrainagewithmodifiedtrocartechniqueusingadrainawaydrainagekit
AT kuratatadayoshi computedtomographyguideddrainagewithmodifiedtrocartechniqueusingadrainawaydrainagekit
AT okadamasahiro computedtomographyguideddrainagewithmodifiedtrocartechniqueusingadrainawaydrainagekit
AT jinzakimasahiro computedtomographyguideddrainagewithmodifiedtrocartechniqueusingadrainawaydrainagekit