Cargando…
Computed Tomography-guided Drainage with Modified Trocar Technique Using a Drainaway Drainage Kit
PURPOSE: Image-guided percutaneous drainage for abscesses is known as a safe and effective treatment. The computed tomography-guided percutaneous drainage kit Drainaway (SB Kawasumi Co., Ltd.), developed on the basis of a modified trocar method, has made it possible to complete the procedure only un...
Autores principales: | , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Japanese Society of Interventional Radiology
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10681752/ https://www.ncbi.nlm.nih.gov/pubmed/38020458 http://dx.doi.org/10.22575/interventionalradiology.2022-0027 |
_version_ | 1785142612348370944 |
---|---|
author | Togawa, Koji Nakatsuka, Seishi Tsukada, Jitsuro Ito, Nobutake Yamamoto, Yosuke Kogo, Togo Yoshikawa, Hiroki Misu, Manabu Tamura, Masashi Soga, Shigeyoshi Inoue, Masanori Yashiro, Hideki Kurata, Tadayoshi Okada, Masahiro Jinzaki, Masahiro |
author_facet | Togawa, Koji Nakatsuka, Seishi Tsukada, Jitsuro Ito, Nobutake Yamamoto, Yosuke Kogo, Togo Yoshikawa, Hiroki Misu, Manabu Tamura, Masashi Soga, Shigeyoshi Inoue, Masanori Yashiro, Hideki Kurata, Tadayoshi Okada, Masahiro Jinzaki, Masahiro |
author_sort | Togawa, Koji |
collection | PubMed |
description | PURPOSE: Image-guided percutaneous drainage for abscesses is known as a safe and effective treatment. The computed tomography-guided percutaneous drainage kit Drainaway (SB Kawasumi Co., Ltd.), developed on the basis of a modified trocar method, has made it possible to complete the procedure only under computed tomography guidance without radiographic fluoroscopy. This study investigated the feasibility and safety of Drainaway for abscess drainage. MATERIAL AND METHODS: In this retrospective observational study, 28 procedures in 27 patients (18 men and 9 women; age 67.0 ± 12.3 years) who underwent computed tomography-guided drainage using Drainaway between March and December 2021 at seven affiliated hospitals were analyzed. Patients with symptomatic, puncturable on computed tomography and refractory abscesses were included. Technical success (successful drainage with computed tomography alone), primary clinical success (successful drainage with Drainaway alone), secondary clinical success (avoidance of surgery), and complications were evaluated. RESULTS: The sites of the abscesses were the intraperitoneal, retroperitoneal, and thoracic cavities in 19, 5, and 2 patients, respectively, and subcutaneous tissue in 1 patient. The mean size of the abscesses was 7.1 ± 3.4 cm. The technical success rate was 96.4%; the ligament of the puncture route could not be penetrated in one case. The primary clinical success rate was 77.8%, whereas the secondary clinical success rate of catheter upsizing or replacement was 96.3%. Complications included one case of biliary pleurisy that required drainage. CONCLUSIONS: Drainaway is a useful device that allows abscess drainage using only computed tomography guidance without radiographic fluoroscopy. |
format | Online Article Text |
id | pubmed-10681752 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | The Japanese Society of Interventional Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-106817522023-08-11 Computed Tomography-guided Drainage with Modified Trocar Technique Using a Drainaway Drainage Kit Togawa, Koji Nakatsuka, Seishi Tsukada, Jitsuro Ito, Nobutake Yamamoto, Yosuke Kogo, Togo Yoshikawa, Hiroki Misu, Manabu Tamura, Masashi Soga, Shigeyoshi Inoue, Masanori Yashiro, Hideki Kurata, Tadayoshi Okada, Masahiro Jinzaki, Masahiro Interv Radiol (Higashimatsuyama) Original Research PURPOSE: Image-guided percutaneous drainage for abscesses is known as a safe and effective treatment. The computed tomography-guided percutaneous drainage kit Drainaway (SB Kawasumi Co., Ltd.), developed on the basis of a modified trocar method, has made it possible to complete the procedure only under computed tomography guidance without radiographic fluoroscopy. This study investigated the feasibility and safety of Drainaway for abscess drainage. MATERIAL AND METHODS: In this retrospective observational study, 28 procedures in 27 patients (18 men and 9 women; age 67.0 ± 12.3 years) who underwent computed tomography-guided drainage using Drainaway between March and December 2021 at seven affiliated hospitals were analyzed. Patients with symptomatic, puncturable on computed tomography and refractory abscesses were included. Technical success (successful drainage with computed tomography alone), primary clinical success (successful drainage with Drainaway alone), secondary clinical success (avoidance of surgery), and complications were evaluated. RESULTS: The sites of the abscesses were the intraperitoneal, retroperitoneal, and thoracic cavities in 19, 5, and 2 patients, respectively, and subcutaneous tissue in 1 patient. The mean size of the abscesses was 7.1 ± 3.4 cm. The technical success rate was 96.4%; the ligament of the puncture route could not be penetrated in one case. The primary clinical success rate was 77.8%, whereas the secondary clinical success rate of catheter upsizing or replacement was 96.3%. Complications included one case of biliary pleurisy that required drainage. CONCLUSIONS: Drainaway is a useful device that allows abscess drainage using only computed tomography guidance without radiographic fluoroscopy. The Japanese Society of Interventional Radiology 2023-08-11 /pmc/articles/PMC10681752/ /pubmed/38020458 http://dx.doi.org/10.22575/interventionalradiology.2022-0027 Text en © 2023 Japanese Society of Interventional Radiology https://creativecommons.org/licenses/by-nc/4.0/Interventional Radiology is an Open Access journal distributed under the Creative Commons Attribution-NonCommercial 4.0 International License. To view the details of this license, please visit (https://creativecommons.org/licenses/by-nc/4.0/). |
spellingShingle | Original Research Togawa, Koji Nakatsuka, Seishi Tsukada, Jitsuro Ito, Nobutake Yamamoto, Yosuke Kogo, Togo Yoshikawa, Hiroki Misu, Manabu Tamura, Masashi Soga, Shigeyoshi Inoue, Masanori Yashiro, Hideki Kurata, Tadayoshi Okada, Masahiro Jinzaki, Masahiro Computed Tomography-guided Drainage with Modified Trocar Technique Using a Drainaway Drainage Kit |
title | Computed Tomography-guided Drainage with Modified Trocar Technique Using a Drainaway Drainage Kit |
title_full | Computed Tomography-guided Drainage with Modified Trocar Technique Using a Drainaway Drainage Kit |
title_fullStr | Computed Tomography-guided Drainage with Modified Trocar Technique Using a Drainaway Drainage Kit |
title_full_unstemmed | Computed Tomography-guided Drainage with Modified Trocar Technique Using a Drainaway Drainage Kit |
title_short | Computed Tomography-guided Drainage with Modified Trocar Technique Using a Drainaway Drainage Kit |
title_sort | computed tomography-guided drainage with modified trocar technique using a drainaway drainage kit |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10681752/ https://www.ncbi.nlm.nih.gov/pubmed/38020458 http://dx.doi.org/10.22575/interventionalradiology.2022-0027 |
work_keys_str_mv | AT togawakoji computedtomographyguideddrainagewithmodifiedtrocartechniqueusingadrainawaydrainagekit AT nakatsukaseishi computedtomographyguideddrainagewithmodifiedtrocartechniqueusingadrainawaydrainagekit AT tsukadajitsuro computedtomographyguideddrainagewithmodifiedtrocartechniqueusingadrainawaydrainagekit AT itonobutake computedtomographyguideddrainagewithmodifiedtrocartechniqueusingadrainawaydrainagekit AT yamamotoyosuke computedtomographyguideddrainagewithmodifiedtrocartechniqueusingadrainawaydrainagekit AT kogotogo computedtomographyguideddrainagewithmodifiedtrocartechniqueusingadrainawaydrainagekit AT yoshikawahiroki computedtomographyguideddrainagewithmodifiedtrocartechniqueusingadrainawaydrainagekit AT misumanabu computedtomographyguideddrainagewithmodifiedtrocartechniqueusingadrainawaydrainagekit AT tamuramasashi computedtomographyguideddrainagewithmodifiedtrocartechniqueusingadrainawaydrainagekit AT sogashigeyoshi computedtomographyguideddrainagewithmodifiedtrocartechniqueusingadrainawaydrainagekit AT inouemasanori computedtomographyguideddrainagewithmodifiedtrocartechniqueusingadrainawaydrainagekit AT yashirohideki computedtomographyguideddrainagewithmodifiedtrocartechniqueusingadrainawaydrainagekit AT kuratatadayoshi computedtomographyguideddrainagewithmodifiedtrocartechniqueusingadrainawaydrainagekit AT okadamasahiro computedtomographyguideddrainagewithmodifiedtrocartechniqueusingadrainawaydrainagekit AT jinzakimasahiro computedtomographyguideddrainagewithmodifiedtrocartechniqueusingadrainawaydrainagekit |