Myocardial perfusion imaging with retrospective gating and integrated correction of attenuation, scatter, respiration, motion, and arrhythmia
BACKGROUND: Absolute quantitative myocardial perfusion SPECT requires addressing of aleatory and epistemic uncertainties in conjunction with providing image quality sufficient for lesion detection and characterization. Iterative reconstruction methods enable the mitigation of the root causes of imag...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10682219/ https://www.ncbi.nlm.nih.gov/pubmed/37758961 http://dx.doi.org/10.1007/s12350-023-03374-5 |
_version_ | 1785150932544126976 |
---|---|
author | Nakajima, Kenichi Shibutani, Takayuki Massanes, Francesc Shimizu, Takeshi Yoshida, Shohei Onoguchi, Masahisa Kinuya, Seigo Vija, A. Hans |
author_facet | Nakajima, Kenichi Shibutani, Takayuki Massanes, Francesc Shimizu, Takeshi Yoshida, Shohei Onoguchi, Masahisa Kinuya, Seigo Vija, A. Hans |
author_sort | Nakajima, Kenichi |
collection | PubMed |
description | BACKGROUND: Absolute quantitative myocardial perfusion SPECT requires addressing of aleatory and epistemic uncertainties in conjunction with providing image quality sufficient for lesion detection and characterization. Iterative reconstruction methods enable the mitigation of the root causes of image degradation. This study aimed to determine the feasibility of a new SPECT/CT method with integrated corrections attempting to enable absolute quantitative cardiac imaging (xSPECT Cardiac; xSC). METHODS: We compared images of prototype xSC and conventional SPECT (Flash3D(TM)) acquired at rest from 56 patients aged 71 ± 12 y with suspected coronary heart disease. The xSC prototype comprised list-mode acquisitions with continuous rotation and subsequent iterative reconstructions with retrospective electrocardiography (ECG) gating. Besides accurate image formation modeling, patient-specific CT-based attenuation and energy window-based scatter correction, additionally we applied mitigation for patient and organ motion between views (inter-view), and within views (intra-view) for both the gated and ungated reconstruction. We then assessed image quality, semiquantitative regional values, and left ventricular function in the images. RESULTS: The quality of all xSC images was acceptable for clinical purposes. A polar map showed more uniform distribution for xSC compared with Flash3D, while lower apical count and higher defect contrast of myocardial infarction (p = 0.0004) were observed on xSC images. Wall motion, 16-gate volume curve, and ejection fraction were at least acceptable, with indication of improvements. The clinical prospectively gated method rejected beats ≥20% in 6 patients, whereas retrospective gating used an average of 98% beats, excluding 2% of beats. We used the list-mode data to create a product equivalent prospectively gated dataset. The dataset showed that the xSC method generated 18% higher count data and images with less noise, with comparable functional variables of volume and LVEF (p = ns). CONCLUSIONS: Quantitative myocardial perfusion imaging with the list-mode-based prototype xSPECT Cardiac is feasible, resulting in images of at least acceptable image quality. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s12350-023-03374-5. |
format | Online Article Text |
id | pubmed-10682219 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-106822192023-11-30 Myocardial perfusion imaging with retrospective gating and integrated correction of attenuation, scatter, respiration, motion, and arrhythmia Nakajima, Kenichi Shibutani, Takayuki Massanes, Francesc Shimizu, Takeshi Yoshida, Shohei Onoguchi, Masahisa Kinuya, Seigo Vija, A. Hans J Nucl Cardiol Original Article BACKGROUND: Absolute quantitative myocardial perfusion SPECT requires addressing of aleatory and epistemic uncertainties in conjunction with providing image quality sufficient for lesion detection and characterization. Iterative reconstruction methods enable the mitigation of the root causes of image degradation. This study aimed to determine the feasibility of a new SPECT/CT method with integrated corrections attempting to enable absolute quantitative cardiac imaging (xSPECT Cardiac; xSC). METHODS: We compared images of prototype xSC and conventional SPECT (Flash3D(TM)) acquired at rest from 56 patients aged 71 ± 12 y with suspected coronary heart disease. The xSC prototype comprised list-mode acquisitions with continuous rotation and subsequent iterative reconstructions with retrospective electrocardiography (ECG) gating. Besides accurate image formation modeling, patient-specific CT-based attenuation and energy window-based scatter correction, additionally we applied mitigation for patient and organ motion between views (inter-view), and within views (intra-view) for both the gated and ungated reconstruction. We then assessed image quality, semiquantitative regional values, and left ventricular function in the images. RESULTS: The quality of all xSC images was acceptable for clinical purposes. A polar map showed more uniform distribution for xSC compared with Flash3D, while lower apical count and higher defect contrast of myocardial infarction (p = 0.0004) were observed on xSC images. Wall motion, 16-gate volume curve, and ejection fraction were at least acceptable, with indication of improvements. The clinical prospectively gated method rejected beats ≥20% in 6 patients, whereas retrospective gating used an average of 98% beats, excluding 2% of beats. We used the list-mode data to create a product equivalent prospectively gated dataset. The dataset showed that the xSC method generated 18% higher count data and images with less noise, with comparable functional variables of volume and LVEF (p = ns). CONCLUSIONS: Quantitative myocardial perfusion imaging with the list-mode-based prototype xSPECT Cardiac is feasible, resulting in images of at least acceptable image quality. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s12350-023-03374-5. Springer International Publishing 2023-09-27 2023 /pmc/articles/PMC10682219/ /pubmed/37758961 http://dx.doi.org/10.1007/s12350-023-03374-5 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Original Article Nakajima, Kenichi Shibutani, Takayuki Massanes, Francesc Shimizu, Takeshi Yoshida, Shohei Onoguchi, Masahisa Kinuya, Seigo Vija, A. Hans Myocardial perfusion imaging with retrospective gating and integrated correction of attenuation, scatter, respiration, motion, and arrhythmia |
title | Myocardial perfusion imaging with retrospective gating and integrated correction of attenuation, scatter, respiration, motion, and arrhythmia |
title_full | Myocardial perfusion imaging with retrospective gating and integrated correction of attenuation, scatter, respiration, motion, and arrhythmia |
title_fullStr | Myocardial perfusion imaging with retrospective gating and integrated correction of attenuation, scatter, respiration, motion, and arrhythmia |
title_full_unstemmed | Myocardial perfusion imaging with retrospective gating and integrated correction of attenuation, scatter, respiration, motion, and arrhythmia |
title_short | Myocardial perfusion imaging with retrospective gating and integrated correction of attenuation, scatter, respiration, motion, and arrhythmia |
title_sort | myocardial perfusion imaging with retrospective gating and integrated correction of attenuation, scatter, respiration, motion, and arrhythmia |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10682219/ https://www.ncbi.nlm.nih.gov/pubmed/37758961 http://dx.doi.org/10.1007/s12350-023-03374-5 |
work_keys_str_mv | AT nakajimakenichi myocardialperfusionimagingwithretrospectivegatingandintegratedcorrectionofattenuationscatterrespirationmotionandarrhythmia AT shibutanitakayuki myocardialperfusionimagingwithretrospectivegatingandintegratedcorrectionofattenuationscatterrespirationmotionandarrhythmia AT massanesfrancesc myocardialperfusionimagingwithretrospectivegatingandintegratedcorrectionofattenuationscatterrespirationmotionandarrhythmia AT shimizutakeshi myocardialperfusionimagingwithretrospectivegatingandintegratedcorrectionofattenuationscatterrespirationmotionandarrhythmia AT yoshidashohei myocardialperfusionimagingwithretrospectivegatingandintegratedcorrectionofattenuationscatterrespirationmotionandarrhythmia AT onoguchimasahisa myocardialperfusionimagingwithretrospectivegatingandintegratedcorrectionofattenuationscatterrespirationmotionandarrhythmia AT kinuyaseigo myocardialperfusionimagingwithretrospectivegatingandintegratedcorrectionofattenuationscatterrespirationmotionandarrhythmia AT vijaahans myocardialperfusionimagingwithretrospectivegatingandintegratedcorrectionofattenuationscatterrespirationmotionandarrhythmia |