Myocardial perfusion imaging with retrospective gating and integrated correction of attenuation, scatter, respiration, motion, and arrhythmia

BACKGROUND: Absolute quantitative myocardial perfusion SPECT requires addressing of aleatory and epistemic uncertainties in conjunction with providing image quality sufficient for lesion detection and characterization. Iterative reconstruction methods enable the mitigation of the root causes of imag...

Descripción completa

Detalles Bibliográficos
Autores principales: Nakajima, Kenichi, Shibutani, Takayuki, Massanes, Francesc, Shimizu, Takeshi, Yoshida, Shohei, Onoguchi, Masahisa, Kinuya, Seigo, Vija, A. Hans
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10682219/
https://www.ncbi.nlm.nih.gov/pubmed/37758961
http://dx.doi.org/10.1007/s12350-023-03374-5
_version_ 1785150932544126976
author Nakajima, Kenichi
Shibutani, Takayuki
Massanes, Francesc
Shimizu, Takeshi
Yoshida, Shohei
Onoguchi, Masahisa
Kinuya, Seigo
Vija, A. Hans
author_facet Nakajima, Kenichi
Shibutani, Takayuki
Massanes, Francesc
Shimizu, Takeshi
Yoshida, Shohei
Onoguchi, Masahisa
Kinuya, Seigo
Vija, A. Hans
author_sort Nakajima, Kenichi
collection PubMed
description BACKGROUND: Absolute quantitative myocardial perfusion SPECT requires addressing of aleatory and epistemic uncertainties in conjunction with providing image quality sufficient for lesion detection and characterization. Iterative reconstruction methods enable the mitigation of the root causes of image degradation. This study aimed to determine the feasibility of a new SPECT/CT method with integrated corrections attempting to enable absolute quantitative cardiac imaging (xSPECT Cardiac; xSC). METHODS: We compared images of prototype xSC and conventional SPECT (Flash3D(TM)) acquired at rest from 56 patients aged 71 ± 12 y with suspected coronary heart disease. The xSC prototype comprised list-mode acquisitions with continuous rotation and subsequent iterative reconstructions with retrospective electrocardiography (ECG) gating. Besides accurate image formation modeling, patient-specific CT-based attenuation and energy window-based scatter correction, additionally we applied mitigation for patient and organ motion between views (inter-view), and within views (intra-view) for both the gated and ungated reconstruction. We then assessed image quality, semiquantitative regional values, and left ventricular function in the images. RESULTS: The quality of all xSC images was acceptable for clinical purposes. A polar map showed more uniform distribution for xSC compared with Flash3D, while lower apical count and higher defect contrast of myocardial infarction (p = 0.0004) were observed on xSC images. Wall motion, 16-gate volume curve, and ejection fraction were at least acceptable, with indication of improvements. The clinical prospectively gated method rejected beats ≥20% in 6 patients, whereas retrospective gating used an average of 98% beats, excluding 2% of beats. We used the list-mode data to create a product equivalent prospectively gated dataset. The dataset showed that the xSC method generated 18% higher count data and images with less noise, with comparable functional variables of volume and LVEF (p = ns). CONCLUSIONS: Quantitative myocardial perfusion imaging with the list-mode-based prototype xSPECT Cardiac is feasible, resulting in images of at least acceptable image quality. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s12350-023-03374-5.
format Online
Article
Text
id pubmed-10682219
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-106822192023-11-30 Myocardial perfusion imaging with retrospective gating and integrated correction of attenuation, scatter, respiration, motion, and arrhythmia Nakajima, Kenichi Shibutani, Takayuki Massanes, Francesc Shimizu, Takeshi Yoshida, Shohei Onoguchi, Masahisa Kinuya, Seigo Vija, A. Hans J Nucl Cardiol Original Article BACKGROUND: Absolute quantitative myocardial perfusion SPECT requires addressing of aleatory and epistemic uncertainties in conjunction with providing image quality sufficient for lesion detection and characterization. Iterative reconstruction methods enable the mitigation of the root causes of image degradation. This study aimed to determine the feasibility of a new SPECT/CT method with integrated corrections attempting to enable absolute quantitative cardiac imaging (xSPECT Cardiac; xSC). METHODS: We compared images of prototype xSC and conventional SPECT (Flash3D(TM)) acquired at rest from 56 patients aged 71 ± 12 y with suspected coronary heart disease. The xSC prototype comprised list-mode acquisitions with continuous rotation and subsequent iterative reconstructions with retrospective electrocardiography (ECG) gating. Besides accurate image formation modeling, patient-specific CT-based attenuation and energy window-based scatter correction, additionally we applied mitigation for patient and organ motion between views (inter-view), and within views (intra-view) for both the gated and ungated reconstruction. We then assessed image quality, semiquantitative regional values, and left ventricular function in the images. RESULTS: The quality of all xSC images was acceptable for clinical purposes. A polar map showed more uniform distribution for xSC compared with Flash3D, while lower apical count and higher defect contrast of myocardial infarction (p = 0.0004) were observed on xSC images. Wall motion, 16-gate volume curve, and ejection fraction were at least acceptable, with indication of improvements. The clinical prospectively gated method rejected beats ≥20% in 6 patients, whereas retrospective gating used an average of 98% beats, excluding 2% of beats. We used the list-mode data to create a product equivalent prospectively gated dataset. The dataset showed that the xSC method generated 18% higher count data and images with less noise, with comparable functional variables of volume and LVEF (p = ns). CONCLUSIONS: Quantitative myocardial perfusion imaging with the list-mode-based prototype xSPECT Cardiac is feasible, resulting in images of at least acceptable image quality. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s12350-023-03374-5. Springer International Publishing 2023-09-27 2023 /pmc/articles/PMC10682219/ /pubmed/37758961 http://dx.doi.org/10.1007/s12350-023-03374-5 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Nakajima, Kenichi
Shibutani, Takayuki
Massanes, Francesc
Shimizu, Takeshi
Yoshida, Shohei
Onoguchi, Masahisa
Kinuya, Seigo
Vija, A. Hans
Myocardial perfusion imaging with retrospective gating and integrated correction of attenuation, scatter, respiration, motion, and arrhythmia
title Myocardial perfusion imaging with retrospective gating and integrated correction of attenuation, scatter, respiration, motion, and arrhythmia
title_full Myocardial perfusion imaging with retrospective gating and integrated correction of attenuation, scatter, respiration, motion, and arrhythmia
title_fullStr Myocardial perfusion imaging with retrospective gating and integrated correction of attenuation, scatter, respiration, motion, and arrhythmia
title_full_unstemmed Myocardial perfusion imaging with retrospective gating and integrated correction of attenuation, scatter, respiration, motion, and arrhythmia
title_short Myocardial perfusion imaging with retrospective gating and integrated correction of attenuation, scatter, respiration, motion, and arrhythmia
title_sort myocardial perfusion imaging with retrospective gating and integrated correction of attenuation, scatter, respiration, motion, and arrhythmia
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10682219/
https://www.ncbi.nlm.nih.gov/pubmed/37758961
http://dx.doi.org/10.1007/s12350-023-03374-5
work_keys_str_mv AT nakajimakenichi myocardialperfusionimagingwithretrospectivegatingandintegratedcorrectionofattenuationscatterrespirationmotionandarrhythmia
AT shibutanitakayuki myocardialperfusionimagingwithretrospectivegatingandintegratedcorrectionofattenuationscatterrespirationmotionandarrhythmia
AT massanesfrancesc myocardialperfusionimagingwithretrospectivegatingandintegratedcorrectionofattenuationscatterrespirationmotionandarrhythmia
AT shimizutakeshi myocardialperfusionimagingwithretrospectivegatingandintegratedcorrectionofattenuationscatterrespirationmotionandarrhythmia
AT yoshidashohei myocardialperfusionimagingwithretrospectivegatingandintegratedcorrectionofattenuationscatterrespirationmotionandarrhythmia
AT onoguchimasahisa myocardialperfusionimagingwithretrospectivegatingandintegratedcorrectionofattenuationscatterrespirationmotionandarrhythmia
AT kinuyaseigo myocardialperfusionimagingwithretrospectivegatingandintegratedcorrectionofattenuationscatterrespirationmotionandarrhythmia
AT vijaahans myocardialperfusionimagingwithretrospectivegatingandintegratedcorrectionofattenuationscatterrespirationmotionandarrhythmia