Cargando…
Sternal closure with sandwiched three-piece bioresorbable mesh reduces postoperative hemorrhage: a retrospective study
BACKGROUND: Median sternotomy is the most performed procedure in cardiac surgery; however, sternal displacement and bleeding remains a problem. This study aimed to investigate whether sternal reconstruction using a sandwiched three-piece bioresorbable mesh plate can prevent postoperative sternal dis...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10683106/ https://www.ncbi.nlm.nih.gov/pubmed/38012743 http://dx.doi.org/10.1186/s13019-023-02460-6 |
_version_ | 1785151118913830912 |
---|---|
author | Yokoyama, Yasutaka Yamamoto, Taira Oyama, Tetsuma Lee, Jiyoung Machida, Yoichiro Endo, Daisuke Sato, Yuichiro Dohi, Shizuyuki Amano, Atsushi Tabata, Minoru |
author_facet | Yokoyama, Yasutaka Yamamoto, Taira Oyama, Tetsuma Lee, Jiyoung Machida, Yoichiro Endo, Daisuke Sato, Yuichiro Dohi, Shizuyuki Amano, Atsushi Tabata, Minoru |
author_sort | Yokoyama, Yasutaka |
collection | PubMed |
description | BACKGROUND: Median sternotomy is the most performed procedure in cardiac surgery; however, sternal displacement and bleeding remains a problem. This study aimed to investigate whether sternal reconstruction using a sandwiched three-piece bioresorbable mesh plate can prevent postoperative sternal displacement and bleeding more than a bioresorbable pin. METHODS: Patients (n = 218) who underwent median sternotomy were classified according to whether a sandwiched three-piece bioresorbable mesh plate and wire cerclage (group M, n = 109) or a bioresorbable pin and wire cerclage (group P, n = 109) were used during sternal reconstruction. The causes of postoperative sternal displacement and bleeding with computed tomography data were analyzed and compared between the groups. RESULTS: The preoperative patient characteristics did not significantly differ between the groups. However, the evaluation of sternal and substernal hematoma on postoperative day 5 using computed tomography showed sternal displacement in 4 (4%) and 22 (20%) patients, and substernal hematoma in 17 (16%) and 41 (38%) patients in groups M and P, respectively; this difference was significant. Furthermore, the amount of bleeding at 6 h postoperatively was lower in group M than in group P (235 ± 147 vs. 284 ± 175 mL, p = 0.0275). Chest reopening, intubation time, and length of intensive care unit and hospital stays did not differ between the groups. The evaluation of substernal hematoma based on computed tomography yielded a significantly lower for group M than for group P, revealing that the mesh plate was an independent predictor of substernal hematoma prevention. CONCLUSION: Sternal fixation with a three-piece bioresorbable mesh plate could prevent postoperative sternal displacement, bleeding, and substernal hematoma more than sternal fixation with a pin. |
format | Online Article Text |
id | pubmed-10683106 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-106831062023-11-30 Sternal closure with sandwiched three-piece bioresorbable mesh reduces postoperative hemorrhage: a retrospective study Yokoyama, Yasutaka Yamamoto, Taira Oyama, Tetsuma Lee, Jiyoung Machida, Yoichiro Endo, Daisuke Sato, Yuichiro Dohi, Shizuyuki Amano, Atsushi Tabata, Minoru J Cardiothorac Surg Research BACKGROUND: Median sternotomy is the most performed procedure in cardiac surgery; however, sternal displacement and bleeding remains a problem. This study aimed to investigate whether sternal reconstruction using a sandwiched three-piece bioresorbable mesh plate can prevent postoperative sternal displacement and bleeding more than a bioresorbable pin. METHODS: Patients (n = 218) who underwent median sternotomy were classified according to whether a sandwiched three-piece bioresorbable mesh plate and wire cerclage (group M, n = 109) or a bioresorbable pin and wire cerclage (group P, n = 109) were used during sternal reconstruction. The causes of postoperative sternal displacement and bleeding with computed tomography data were analyzed and compared between the groups. RESULTS: The preoperative patient characteristics did not significantly differ between the groups. However, the evaluation of sternal and substernal hematoma on postoperative day 5 using computed tomography showed sternal displacement in 4 (4%) and 22 (20%) patients, and substernal hematoma in 17 (16%) and 41 (38%) patients in groups M and P, respectively; this difference was significant. Furthermore, the amount of bleeding at 6 h postoperatively was lower in group M than in group P (235 ± 147 vs. 284 ± 175 mL, p = 0.0275). Chest reopening, intubation time, and length of intensive care unit and hospital stays did not differ between the groups. The evaluation of substernal hematoma based on computed tomography yielded a significantly lower for group M than for group P, revealing that the mesh plate was an independent predictor of substernal hematoma prevention. CONCLUSION: Sternal fixation with a three-piece bioresorbable mesh plate could prevent postoperative sternal displacement, bleeding, and substernal hematoma more than sternal fixation with a pin. BioMed Central 2023-11-27 /pmc/articles/PMC10683106/ /pubmed/38012743 http://dx.doi.org/10.1186/s13019-023-02460-6 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Yokoyama, Yasutaka Yamamoto, Taira Oyama, Tetsuma Lee, Jiyoung Machida, Yoichiro Endo, Daisuke Sato, Yuichiro Dohi, Shizuyuki Amano, Atsushi Tabata, Minoru Sternal closure with sandwiched three-piece bioresorbable mesh reduces postoperative hemorrhage: a retrospective study |
title | Sternal closure with sandwiched three-piece bioresorbable mesh reduces postoperative hemorrhage: a retrospective study |
title_full | Sternal closure with sandwiched three-piece bioresorbable mesh reduces postoperative hemorrhage: a retrospective study |
title_fullStr | Sternal closure with sandwiched three-piece bioresorbable mesh reduces postoperative hemorrhage: a retrospective study |
title_full_unstemmed | Sternal closure with sandwiched three-piece bioresorbable mesh reduces postoperative hemorrhage: a retrospective study |
title_short | Sternal closure with sandwiched three-piece bioresorbable mesh reduces postoperative hemorrhage: a retrospective study |
title_sort | sternal closure with sandwiched three-piece bioresorbable mesh reduces postoperative hemorrhage: a retrospective study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10683106/ https://www.ncbi.nlm.nih.gov/pubmed/38012743 http://dx.doi.org/10.1186/s13019-023-02460-6 |
work_keys_str_mv | AT yokoyamayasutaka sternalclosurewithsandwichedthreepiecebioresorbablemeshreducespostoperativehemorrhagearetrospectivestudy AT yamamototaira sternalclosurewithsandwichedthreepiecebioresorbablemeshreducespostoperativehemorrhagearetrospectivestudy AT oyamatetsuma sternalclosurewithsandwichedthreepiecebioresorbablemeshreducespostoperativehemorrhagearetrospectivestudy AT leejiyoung sternalclosurewithsandwichedthreepiecebioresorbablemeshreducespostoperativehemorrhagearetrospectivestudy AT machidayoichiro sternalclosurewithsandwichedthreepiecebioresorbablemeshreducespostoperativehemorrhagearetrospectivestudy AT endodaisuke sternalclosurewithsandwichedthreepiecebioresorbablemeshreducespostoperativehemorrhagearetrospectivestudy AT satoyuichiro sternalclosurewithsandwichedthreepiecebioresorbablemeshreducespostoperativehemorrhagearetrospectivestudy AT dohishizuyuki sternalclosurewithsandwichedthreepiecebioresorbablemeshreducespostoperativehemorrhagearetrospectivestudy AT amanoatsushi sternalclosurewithsandwichedthreepiecebioresorbablemeshreducespostoperativehemorrhagearetrospectivestudy AT tabataminoru sternalclosurewithsandwichedthreepiecebioresorbablemeshreducespostoperativehemorrhagearetrospectivestudy |