Cargando…
Reliability and reproducibility of CBCT assessment of mandibular changes before and after treatment for Class III growing patients – an easy and quick way for evaluation
The objective of this study was to evaluate intraobserver reliability and inter-observer reproducibility of a 3-dimensional (3D) assessment method for mandibular changes of growing patients after orthodontic treatment for Class III malocclusion. Methods Cone-beam computed tomography (CBCT) scans wer...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10683261/ https://www.ncbi.nlm.nih.gov/pubmed/38017394 http://dx.doi.org/10.1186/s12887-023-04404-4 |
_version_ | 1785151155561562112 |
---|---|
author | Hu, XiaoYing Cheung, Gary Shun Pan Zhang, YiYang Sun, RuoNan Dong, FuSheng |
author_facet | Hu, XiaoYing Cheung, Gary Shun Pan Zhang, YiYang Sun, RuoNan Dong, FuSheng |
author_sort | Hu, XiaoYing |
collection | PubMed |
description | The objective of this study was to evaluate intraobserver reliability and inter-observer reproducibility of a 3-dimensional (3D) assessment method for mandibular changes of growing patients after orthodontic treatment for Class III malocclusion. Methods Cone-beam computed tomography (CBCT) scans were performed before and after orthodontic treatment for 27 patients. During the scan, the patient was positioned such that his/her mandibular plane was parallel to floor. Three observers independently worked on the DICOM data, reconstructed the pre- and post-treatment 3D models in software, selected the stable anatomical structures (basal bone area from the lingual surface of the symphysis to the distal aspect of the first molars) to guide the automated superimposition process. Then, each observer registered 14 anatomical landmarks on the virtual models, for three times after suitable interval, to generate 3 sets of coordinates; the mean was taken as the coordinates for that particular landmark. The intraobserver reliability and inter-observer reproducibility of the method were analyzed. Results The ICCs was > 0.90 for 25 (92.6%) of the intraobserver assessments. The precision of the measurement method was < 0.3 mm in 24 (88.9%) cases. The interobserver reproducibility errors were < 0.3 mm in 21 of the 27 cases. Conclusions The intraobserver reliability and inter-observer reproducibility of 3D assessment of mandibular changes using the virtual models were excellent. |
format | Online Article Text |
id | pubmed-10683261 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-106832612023-11-30 Reliability and reproducibility of CBCT assessment of mandibular changes before and after treatment for Class III growing patients – an easy and quick way for evaluation Hu, XiaoYing Cheung, Gary Shun Pan Zhang, YiYang Sun, RuoNan Dong, FuSheng BMC Pediatr Research The objective of this study was to evaluate intraobserver reliability and inter-observer reproducibility of a 3-dimensional (3D) assessment method for mandibular changes of growing patients after orthodontic treatment for Class III malocclusion. Methods Cone-beam computed tomography (CBCT) scans were performed before and after orthodontic treatment for 27 patients. During the scan, the patient was positioned such that his/her mandibular plane was parallel to floor. Three observers independently worked on the DICOM data, reconstructed the pre- and post-treatment 3D models in software, selected the stable anatomical structures (basal bone area from the lingual surface of the symphysis to the distal aspect of the first molars) to guide the automated superimposition process. Then, each observer registered 14 anatomical landmarks on the virtual models, for three times after suitable interval, to generate 3 sets of coordinates; the mean was taken as the coordinates for that particular landmark. The intraobserver reliability and inter-observer reproducibility of the method were analyzed. Results The ICCs was > 0.90 for 25 (92.6%) of the intraobserver assessments. The precision of the measurement method was < 0.3 mm in 24 (88.9%) cases. The interobserver reproducibility errors were < 0.3 mm in 21 of the 27 cases. Conclusions The intraobserver reliability and inter-observer reproducibility of 3D assessment of mandibular changes using the virtual models were excellent. BioMed Central 2023-11-28 /pmc/articles/PMC10683261/ /pubmed/38017394 http://dx.doi.org/10.1186/s12887-023-04404-4 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Hu, XiaoYing Cheung, Gary Shun Pan Zhang, YiYang Sun, RuoNan Dong, FuSheng Reliability and reproducibility of CBCT assessment of mandibular changes before and after treatment for Class III growing patients – an easy and quick way for evaluation |
title | Reliability and reproducibility of CBCT assessment of mandibular changes before and after treatment for Class III growing patients – an easy and quick way for evaluation |
title_full | Reliability and reproducibility of CBCT assessment of mandibular changes before and after treatment for Class III growing patients – an easy and quick way for evaluation |
title_fullStr | Reliability and reproducibility of CBCT assessment of mandibular changes before and after treatment for Class III growing patients – an easy and quick way for evaluation |
title_full_unstemmed | Reliability and reproducibility of CBCT assessment of mandibular changes before and after treatment for Class III growing patients – an easy and quick way for evaluation |
title_short | Reliability and reproducibility of CBCT assessment of mandibular changes before and after treatment for Class III growing patients – an easy and quick way for evaluation |
title_sort | reliability and reproducibility of cbct assessment of mandibular changes before and after treatment for class iii growing patients – an easy and quick way for evaluation |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10683261/ https://www.ncbi.nlm.nih.gov/pubmed/38017394 http://dx.doi.org/10.1186/s12887-023-04404-4 |
work_keys_str_mv | AT huxiaoying reliabilityandreproducibilityofcbctassessmentofmandibularchangesbeforeandaftertreatmentforclassiiigrowingpatientsaneasyandquickwayforevaluation AT cheunggaryshunpan reliabilityandreproducibilityofcbctassessmentofmandibularchangesbeforeandaftertreatmentforclassiiigrowingpatientsaneasyandquickwayforevaluation AT zhangyiyang reliabilityandreproducibilityofcbctassessmentofmandibularchangesbeforeandaftertreatmentforclassiiigrowingpatientsaneasyandquickwayforevaluation AT sunruonan reliabilityandreproducibilityofcbctassessmentofmandibularchangesbeforeandaftertreatmentforclassiiigrowingpatientsaneasyandquickwayforevaluation AT dongfusheng reliabilityandreproducibilityofcbctassessmentofmandibularchangesbeforeandaftertreatmentforclassiiigrowingpatientsaneasyandquickwayforevaluation |