Cargando…

Comparative study of the sensitivity of ultra-high-resolution CT and high-resolution CT in the diagnosis of isolated fenestral otosclerosis

PURPOSE: To compare the diagnostic sensitivity of ultra-high-resolution computed tomography (U-HRCT) and HRCT in isolated fenestral otosclerosis (IFO). METHODS: A retrospective analysis was conducted on 85 patients (85 ears) diagnosed with IFO between October 2020 and November 2022. U-HRCT (0.1 mm t...

Descripción completa

Detalles Bibliográficos
Autores principales: Xu, Ning, Ding, Heyu, Tang, Ruowei, Li, Xiaoshuai, Zhang, Zhengyu, Lv, Han, Dai, Chihang, Qiu, Xiaoyu, Huang, Yan, Han, Xu, Wang, Guo-Peng, Liu, Yuhe, Gong, Shusheng, Yang, Zhenghan, Wang, Zhenchang, Zhao, Pengfei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Vienna 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10684447/
https://www.ncbi.nlm.nih.gov/pubmed/38015307
http://dx.doi.org/10.1186/s13244-023-01562-y
_version_ 1785151404316295168
author Xu, Ning
Ding, Heyu
Tang, Ruowei
Li, Xiaoshuai
Zhang, Zhengyu
Lv, Han
Dai, Chihang
Qiu, Xiaoyu
Huang, Yan
Han, Xu
Wang, Guo-Peng
Liu, Yuhe
Gong, Shusheng
Yang, Zhenghan
Wang, Zhenchang
Zhao, Pengfei
author_facet Xu, Ning
Ding, Heyu
Tang, Ruowei
Li, Xiaoshuai
Zhang, Zhengyu
Lv, Han
Dai, Chihang
Qiu, Xiaoyu
Huang, Yan
Han, Xu
Wang, Guo-Peng
Liu, Yuhe
Gong, Shusheng
Yang, Zhenghan
Wang, Zhenchang
Zhao, Pengfei
author_sort Xu, Ning
collection PubMed
description PURPOSE: To compare the diagnostic sensitivity of ultra-high-resolution computed tomography (U-HRCT) and HRCT in isolated fenestral otosclerosis (IFO). METHODS: A retrospective analysis was conducted on 85 patients (85 ears) diagnosed with IFO between October 2020 and November 2022. U-HRCT (0.1 mm thickness) was performed for 20 ears, HRCT (0.67 mm thickness) for 45 ears, and both for 20 ears. The images were evaluated by general radiologists and neuroradiologists who were blinded to the diagnosis and surgical information. The diagnostic sensitivity of U-HRCT and HRCT for detecting IFO was compared between the two groups. RESULTS: Excellent inter-observer agreement existed between the two neuroradiologists (Cohen’s κ coefficient 0.806, 95% CI 0.692–0.920), with good agreement between the general radiologists (Cohen’s κ coefficient 0.680, 95% CI 0.417–0.943). U-HRCT had a sensitivity of 100% (40/40 ears) for neuroradiologists and 87.5% (35/40 ears) for general radiologists, significantly higher than HRCT (89.2% [58/65 ears] for neuroradiologists; 41.5% [27/65 ears] for general radiologists) (p = 0.042, p′ < 0.000). General radiologists’ sensitivity with HRCT was significantly lower compared to neuroradiologists (p < 0.000), but no significant difference was observed when general radiologists switched to U-HRCT (p = 0.152). Among the 20 ears that underwent both examinations, U-HRCT detected lesions smaller than 1 mm in 5 ears, whereas HRCT’s sensitivity for neuroradiologists was 40% (2/5 ears), significantly lower than for lesions larger than 1 mm (93.3%, 14/15 ears, p = 0.032). CONCLUSION: U-HRCT exhibits higher sensitivity than HRCT in diagnosing IFO, suggesting its potential as a screening tool for suspected otosclerosis patients. CRITICAL RELEVANCE STATEMENT: Ultra-high-resolution computed tomography has the potential to become a screening tool in patients with suspected otosclerosis and to bridge the diagnostic accuracy gap between general radiologists and neuroradiologists. KEY POINTS: • U-HRCT exhibits higher sensitivity than HRCT in the diagnosis of IFO. • U-HRCT has a significant advantage in the detection of less than 1 mm IFO. • U-HRCT has the potential to be used for screening of patients with suspected otosclerosis. GRAPHICAL ABSTRACT: [Image: see text]
format Online
Article
Text
id pubmed-10684447
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer Vienna
record_format MEDLINE/PubMed
spelling pubmed-106844472023-11-30 Comparative study of the sensitivity of ultra-high-resolution CT and high-resolution CT in the diagnosis of isolated fenestral otosclerosis Xu, Ning Ding, Heyu Tang, Ruowei Li, Xiaoshuai Zhang, Zhengyu Lv, Han Dai, Chihang Qiu, Xiaoyu Huang, Yan Han, Xu Wang, Guo-Peng Liu, Yuhe Gong, Shusheng Yang, Zhenghan Wang, Zhenchang Zhao, Pengfei Insights Imaging Original Article PURPOSE: To compare the diagnostic sensitivity of ultra-high-resolution computed tomography (U-HRCT) and HRCT in isolated fenestral otosclerosis (IFO). METHODS: A retrospective analysis was conducted on 85 patients (85 ears) diagnosed with IFO between October 2020 and November 2022. U-HRCT (0.1 mm thickness) was performed for 20 ears, HRCT (0.67 mm thickness) for 45 ears, and both for 20 ears. The images were evaluated by general radiologists and neuroradiologists who were blinded to the diagnosis and surgical information. The diagnostic sensitivity of U-HRCT and HRCT for detecting IFO was compared between the two groups. RESULTS: Excellent inter-observer agreement existed between the two neuroradiologists (Cohen’s κ coefficient 0.806, 95% CI 0.692–0.920), with good agreement between the general radiologists (Cohen’s κ coefficient 0.680, 95% CI 0.417–0.943). U-HRCT had a sensitivity of 100% (40/40 ears) for neuroradiologists and 87.5% (35/40 ears) for general radiologists, significantly higher than HRCT (89.2% [58/65 ears] for neuroradiologists; 41.5% [27/65 ears] for general radiologists) (p = 0.042, p′ < 0.000). General radiologists’ sensitivity with HRCT was significantly lower compared to neuroradiologists (p < 0.000), but no significant difference was observed when general radiologists switched to U-HRCT (p = 0.152). Among the 20 ears that underwent both examinations, U-HRCT detected lesions smaller than 1 mm in 5 ears, whereas HRCT’s sensitivity for neuroradiologists was 40% (2/5 ears), significantly lower than for lesions larger than 1 mm (93.3%, 14/15 ears, p = 0.032). CONCLUSION: U-HRCT exhibits higher sensitivity than HRCT in diagnosing IFO, suggesting its potential as a screening tool for suspected otosclerosis patients. CRITICAL RELEVANCE STATEMENT: Ultra-high-resolution computed tomography has the potential to become a screening tool in patients with suspected otosclerosis and to bridge the diagnostic accuracy gap between general radiologists and neuroradiologists. KEY POINTS: • U-HRCT exhibits higher sensitivity than HRCT in the diagnosis of IFO. • U-HRCT has a significant advantage in the detection of less than 1 mm IFO. • U-HRCT has the potential to be used for screening of patients with suspected otosclerosis. GRAPHICAL ABSTRACT: [Image: see text] Springer Vienna 2023-11-28 /pmc/articles/PMC10684447/ /pubmed/38015307 http://dx.doi.org/10.1186/s13244-023-01562-y Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Xu, Ning
Ding, Heyu
Tang, Ruowei
Li, Xiaoshuai
Zhang, Zhengyu
Lv, Han
Dai, Chihang
Qiu, Xiaoyu
Huang, Yan
Han, Xu
Wang, Guo-Peng
Liu, Yuhe
Gong, Shusheng
Yang, Zhenghan
Wang, Zhenchang
Zhao, Pengfei
Comparative study of the sensitivity of ultra-high-resolution CT and high-resolution CT in the diagnosis of isolated fenestral otosclerosis
title Comparative study of the sensitivity of ultra-high-resolution CT and high-resolution CT in the diagnosis of isolated fenestral otosclerosis
title_full Comparative study of the sensitivity of ultra-high-resolution CT and high-resolution CT in the diagnosis of isolated fenestral otosclerosis
title_fullStr Comparative study of the sensitivity of ultra-high-resolution CT and high-resolution CT in the diagnosis of isolated fenestral otosclerosis
title_full_unstemmed Comparative study of the sensitivity of ultra-high-resolution CT and high-resolution CT in the diagnosis of isolated fenestral otosclerosis
title_short Comparative study of the sensitivity of ultra-high-resolution CT and high-resolution CT in the diagnosis of isolated fenestral otosclerosis
title_sort comparative study of the sensitivity of ultra-high-resolution ct and high-resolution ct in the diagnosis of isolated fenestral otosclerosis
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10684447/
https://www.ncbi.nlm.nih.gov/pubmed/38015307
http://dx.doi.org/10.1186/s13244-023-01562-y
work_keys_str_mv AT xuning comparativestudyofthesensitivityofultrahighresolutionctandhighresolutionctinthediagnosisofisolatedfenestralotosclerosis
AT dingheyu comparativestudyofthesensitivityofultrahighresolutionctandhighresolutionctinthediagnosisofisolatedfenestralotosclerosis
AT tangruowei comparativestudyofthesensitivityofultrahighresolutionctandhighresolutionctinthediagnosisofisolatedfenestralotosclerosis
AT lixiaoshuai comparativestudyofthesensitivityofultrahighresolutionctandhighresolutionctinthediagnosisofisolatedfenestralotosclerosis
AT zhangzhengyu comparativestudyofthesensitivityofultrahighresolutionctandhighresolutionctinthediagnosisofisolatedfenestralotosclerosis
AT lvhan comparativestudyofthesensitivityofultrahighresolutionctandhighresolutionctinthediagnosisofisolatedfenestralotosclerosis
AT daichihang comparativestudyofthesensitivityofultrahighresolutionctandhighresolutionctinthediagnosisofisolatedfenestralotosclerosis
AT qiuxiaoyu comparativestudyofthesensitivityofultrahighresolutionctandhighresolutionctinthediagnosisofisolatedfenestralotosclerosis
AT huangyan comparativestudyofthesensitivityofultrahighresolutionctandhighresolutionctinthediagnosisofisolatedfenestralotosclerosis
AT hanxu comparativestudyofthesensitivityofultrahighresolutionctandhighresolutionctinthediagnosisofisolatedfenestralotosclerosis
AT wangguopeng comparativestudyofthesensitivityofultrahighresolutionctandhighresolutionctinthediagnosisofisolatedfenestralotosclerosis
AT liuyuhe comparativestudyofthesensitivityofultrahighresolutionctandhighresolutionctinthediagnosisofisolatedfenestralotosclerosis
AT gongshusheng comparativestudyofthesensitivityofultrahighresolutionctandhighresolutionctinthediagnosisofisolatedfenestralotosclerosis
AT yangzhenghan comparativestudyofthesensitivityofultrahighresolutionctandhighresolutionctinthediagnosisofisolatedfenestralotosclerosis
AT wangzhenchang comparativestudyofthesensitivityofultrahighresolutionctandhighresolutionctinthediagnosisofisolatedfenestralotosclerosis
AT zhaopengfei comparativestudyofthesensitivityofultrahighresolutionctandhighresolutionctinthediagnosisofisolatedfenestralotosclerosis