Cargando…
The effect of different posterior inclinations of tibial component on tibiofemoral contact pressures after unicompartmental knee arthroplasty
BACKGROUND: Different posterior inclinations of tibial component after unicompartmental knee arthroplasty (UKA) may lead to different biomechanical characteristics of the knee joint. This finite element study was designed to investigate the tibiofemoral contact pressures after UKA with different pos...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10685639/ https://www.ncbi.nlm.nih.gov/pubmed/38031176 http://dx.doi.org/10.1186/s13018-023-04222-5 |
_version_ | 1785151678882775040 |
---|---|
author | Yuan, Bo Mo, Zhongjun Zhang, Kuan Zhu, Xu Yan, Songhua Zeng, Jizhou |
author_facet | Yuan, Bo Mo, Zhongjun Zhang, Kuan Zhu, Xu Yan, Songhua Zeng, Jizhou |
author_sort | Yuan, Bo |
collection | PubMed |
description | BACKGROUND: Different posterior inclinations of tibial component after unicompartmental knee arthroplasty (UKA) may lead to different biomechanical characteristics of the knee joint. This finite element study was designed to investigate the tibiofemoral contact pressures after UKA with different posterior inclinations of tibial component. METHODS: Finite element model of a healthy knee joint was constructed, and mobile-bearing (MB) UKA models with 5 different posterior inclinations (3°, 5°, 7°, 9° and 11°) of tibial components were simulated. The maximum contact pressures of tibial plateau cartilage in the lateral compartment and polyethylene insert in the medial compartment were calculated based on the ground reaction force and the angle of the knee flexion obtained by 3D motion capture system. RESULTS: The loading ratio of medial and lateral compartments during standing stance (medial 54.49%, lateral 45.51%) and tibial anterior displacement (134 N, 3.89 mm) of healthy knee was basically consistent with previous experimental data. The maximum contact pressures of the medial meniscus and lateral tibial plateau cartilage of the healthy knee during standing stance were 2.14 MPa and 1.57 MPa, respectively. At the static standing phase, the maximum contact pressures of the polyethylene insert decreased from 17.90 to 17.29 Mpa, and the maximum contact pressures of the tibial plateau cartilage in the lateral compartment increased from 0.81 to 0.92 Mpa following an increase in the posterior inclination of the tibial component. At the first peak of ground reaction force, the maximum contact pressures of polyethylene insert increased from 22.37 to 25.16 MPa, and the maximum contact pressures of tibial plateau cartilage in the lateral compartment increased from 3.03 to 3.33 MPa, with the increase in the posterior inclination of the tibial component. At the second peak of ground reaction force, the maximum contact pressures of polyethylene insert decreased from 2.34 to 2.22 MPa with the increase in posterior inclination of tibial component. CONCLUSION: The preoperative and postoperative finite element models of MB UKA were well established. The results showed that the maximum contact pressures of the polyethylene insert did not change significantly with the increase in the posterior inclination of the tibial prosthesis, while the maximum contact pressures of the tibial plateau cartilage of the lateral compartment increased when the posterior inclination of the tibial prosthesis was > 7°. Our results also show that the maximum contact pressures were greater with an excessive inclination angle (11°) of the tibial component, and the pressures of the tibial plateau cartilage in the lateral compartment were more concentrated on the posterior area. This study, therefore, proposes that excessive osteotomy should be avoided. |
format | Online Article Text |
id | pubmed-10685639 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-106856392023-11-30 The effect of different posterior inclinations of tibial component on tibiofemoral contact pressures after unicompartmental knee arthroplasty Yuan, Bo Mo, Zhongjun Zhang, Kuan Zhu, Xu Yan, Songhua Zeng, Jizhou J Orthop Surg Res Research Article BACKGROUND: Different posterior inclinations of tibial component after unicompartmental knee arthroplasty (UKA) may lead to different biomechanical characteristics of the knee joint. This finite element study was designed to investigate the tibiofemoral contact pressures after UKA with different posterior inclinations of tibial component. METHODS: Finite element model of a healthy knee joint was constructed, and mobile-bearing (MB) UKA models with 5 different posterior inclinations (3°, 5°, 7°, 9° and 11°) of tibial components were simulated. The maximum contact pressures of tibial plateau cartilage in the lateral compartment and polyethylene insert in the medial compartment were calculated based on the ground reaction force and the angle of the knee flexion obtained by 3D motion capture system. RESULTS: The loading ratio of medial and lateral compartments during standing stance (medial 54.49%, lateral 45.51%) and tibial anterior displacement (134 N, 3.89 mm) of healthy knee was basically consistent with previous experimental data. The maximum contact pressures of the medial meniscus and lateral tibial plateau cartilage of the healthy knee during standing stance were 2.14 MPa and 1.57 MPa, respectively. At the static standing phase, the maximum contact pressures of the polyethylene insert decreased from 17.90 to 17.29 Mpa, and the maximum contact pressures of the tibial plateau cartilage in the lateral compartment increased from 0.81 to 0.92 Mpa following an increase in the posterior inclination of the tibial component. At the first peak of ground reaction force, the maximum contact pressures of polyethylene insert increased from 22.37 to 25.16 MPa, and the maximum contact pressures of tibial plateau cartilage in the lateral compartment increased from 3.03 to 3.33 MPa, with the increase in the posterior inclination of the tibial component. At the second peak of ground reaction force, the maximum contact pressures of polyethylene insert decreased from 2.34 to 2.22 MPa with the increase in posterior inclination of tibial component. CONCLUSION: The preoperative and postoperative finite element models of MB UKA were well established. The results showed that the maximum contact pressures of the polyethylene insert did not change significantly with the increase in the posterior inclination of the tibial prosthesis, while the maximum contact pressures of the tibial plateau cartilage of the lateral compartment increased when the posterior inclination of the tibial prosthesis was > 7°. Our results also show that the maximum contact pressures were greater with an excessive inclination angle (11°) of the tibial component, and the pressures of the tibial plateau cartilage in the lateral compartment were more concentrated on the posterior area. This study, therefore, proposes that excessive osteotomy should be avoided. BioMed Central 2023-11-29 /pmc/articles/PMC10685639/ /pubmed/38031176 http://dx.doi.org/10.1186/s13018-023-04222-5 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Yuan, Bo Mo, Zhongjun Zhang, Kuan Zhu, Xu Yan, Songhua Zeng, Jizhou The effect of different posterior inclinations of tibial component on tibiofemoral contact pressures after unicompartmental knee arthroplasty |
title | The effect of different posterior inclinations of tibial component on tibiofemoral contact pressures after unicompartmental knee arthroplasty |
title_full | The effect of different posterior inclinations of tibial component on tibiofemoral contact pressures after unicompartmental knee arthroplasty |
title_fullStr | The effect of different posterior inclinations of tibial component on tibiofemoral contact pressures after unicompartmental knee arthroplasty |
title_full_unstemmed | The effect of different posterior inclinations of tibial component on tibiofemoral contact pressures after unicompartmental knee arthroplasty |
title_short | The effect of different posterior inclinations of tibial component on tibiofemoral contact pressures after unicompartmental knee arthroplasty |
title_sort | effect of different posterior inclinations of tibial component on tibiofemoral contact pressures after unicompartmental knee arthroplasty |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10685639/ https://www.ncbi.nlm.nih.gov/pubmed/38031176 http://dx.doi.org/10.1186/s13018-023-04222-5 |
work_keys_str_mv | AT yuanbo theeffectofdifferentposteriorinclinationsoftibialcomponentontibiofemoralcontactpressuresafterunicompartmentalkneearthroplasty AT mozhongjun theeffectofdifferentposteriorinclinationsoftibialcomponentontibiofemoralcontactpressuresafterunicompartmentalkneearthroplasty AT zhangkuan theeffectofdifferentposteriorinclinationsoftibialcomponentontibiofemoralcontactpressuresafterunicompartmentalkneearthroplasty AT zhuxu theeffectofdifferentposteriorinclinationsoftibialcomponentontibiofemoralcontactpressuresafterunicompartmentalkneearthroplasty AT yansonghua theeffectofdifferentposteriorinclinationsoftibialcomponentontibiofemoralcontactpressuresafterunicompartmentalkneearthroplasty AT zengjizhou theeffectofdifferentposteriorinclinationsoftibialcomponentontibiofemoralcontactpressuresafterunicompartmentalkneearthroplasty AT yuanbo effectofdifferentposteriorinclinationsoftibialcomponentontibiofemoralcontactpressuresafterunicompartmentalkneearthroplasty AT mozhongjun effectofdifferentposteriorinclinationsoftibialcomponentontibiofemoralcontactpressuresafterunicompartmentalkneearthroplasty AT zhangkuan effectofdifferentposteriorinclinationsoftibialcomponentontibiofemoralcontactpressuresafterunicompartmentalkneearthroplasty AT zhuxu effectofdifferentposteriorinclinationsoftibialcomponentontibiofemoralcontactpressuresafterunicompartmentalkneearthroplasty AT yansonghua effectofdifferentposteriorinclinationsoftibialcomponentontibiofemoralcontactpressuresafterunicompartmentalkneearthroplasty AT zengjizhou effectofdifferentposteriorinclinationsoftibialcomponentontibiofemoralcontactpressuresafterunicompartmentalkneearthroplasty |