Cargando…
Clinical application of a digital semi-rigid bridge space maintainer fabricated from polyetheretherketone for premature loss of primary molars
BACKGROUND: Premature loss of primary molars can be treated with a band loop space maintainer (SM). However, fabricating a conventional band loop SM requires multiple clinical and laboratory procedures, which can potentially affect the accuracy of the SM. Moreover, the conventional SM is unable to f...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10685679/ https://www.ncbi.nlm.nih.gov/pubmed/38031148 http://dx.doi.org/10.1186/s12903-023-03570-2 |
_version_ | 1785151688290598912 |
---|---|
author | Wang, Qi Zhang, Zhenzhen Zhong, Sheng Liu, Jiajia Hu, Ying Zhou, Ziling Zhang, Caidi Bai, Shizhu Wu, Li’an |
author_facet | Wang, Qi Zhang, Zhenzhen Zhong, Sheng Liu, Jiajia Hu, Ying Zhou, Ziling Zhang, Caidi Bai, Shizhu Wu, Li’an |
author_sort | Wang, Qi |
collection | PubMed |
description | BACKGROUND: Premature loss of primary molars can be treated with a band loop space maintainer (SM). However, fabricating a conventional band loop SM requires multiple clinical and laboratory procedures, which can potentially affect the accuracy of the SM. Moreover, the conventional SM is unable to fully restore masticatory function and maintain the vertical dimension of the edentulous space. In this current study, a fully digital workflow to fabricate a semi-rigid bridge SM made from polyetheretherketone (PEEK) has been described and evaluated for its clinical effectiveness. METHODS: A total of 15 children (eight males and seven females) between the ages of 4–8 years, who experienced the premature loss of a single primary molar, were included in this study. Digital impressions were taken using the CEREC CAD/CAM chair system and imported into CAD software to design the semi-rigid bridge SM, which was fabricated using PEEK block as the maintainer material. The digital SM was tried-in and bonded to the abutment with resin cement. The edentulous space was measured immediately after bonding (T0) and 1 month (T1), 3 months (T2), and 6 months (T3) after treatment. The periodontal condition and mobility of the SM and abutment were also examined. RESULTS: The use of digital impressions resulted in a decreased occurrence of the pharyngeal reflex. The digital semi-rigid bridge SM, fabricated with PEEK, was both convenient and aesthetically pleasing, and successfully restored the anatomy and masticatory function of the missing primary molar. None of the 15 semi-rigid bridge SMs or abutments became loose or fell off during the study, and only one child presented with gingivitis. Furthermore, the difference in the edentulous space at T0, T1, T2, and T3 was not statistically significant (all P > 0.05). CONCLUSIONS: The digital semi-rigid bridge SM fabricated with PEEK was clinically effective in maintaining the missing space and had advantages over the traditional band/crown loop SM. |
format | Online Article Text |
id | pubmed-10685679 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-106856792023-11-30 Clinical application of a digital semi-rigid bridge space maintainer fabricated from polyetheretherketone for premature loss of primary molars Wang, Qi Zhang, Zhenzhen Zhong, Sheng Liu, Jiajia Hu, Ying Zhou, Ziling Zhang, Caidi Bai, Shizhu Wu, Li’an BMC Oral Health Research BACKGROUND: Premature loss of primary molars can be treated with a band loop space maintainer (SM). However, fabricating a conventional band loop SM requires multiple clinical and laboratory procedures, which can potentially affect the accuracy of the SM. Moreover, the conventional SM is unable to fully restore masticatory function and maintain the vertical dimension of the edentulous space. In this current study, a fully digital workflow to fabricate a semi-rigid bridge SM made from polyetheretherketone (PEEK) has been described and evaluated for its clinical effectiveness. METHODS: A total of 15 children (eight males and seven females) between the ages of 4–8 years, who experienced the premature loss of a single primary molar, were included in this study. Digital impressions were taken using the CEREC CAD/CAM chair system and imported into CAD software to design the semi-rigid bridge SM, which was fabricated using PEEK block as the maintainer material. The digital SM was tried-in and bonded to the abutment with resin cement. The edentulous space was measured immediately after bonding (T0) and 1 month (T1), 3 months (T2), and 6 months (T3) after treatment. The periodontal condition and mobility of the SM and abutment were also examined. RESULTS: The use of digital impressions resulted in a decreased occurrence of the pharyngeal reflex. The digital semi-rigid bridge SM, fabricated with PEEK, was both convenient and aesthetically pleasing, and successfully restored the anatomy and masticatory function of the missing primary molar. None of the 15 semi-rigid bridge SMs or abutments became loose or fell off during the study, and only one child presented with gingivitis. Furthermore, the difference in the edentulous space at T0, T1, T2, and T3 was not statistically significant (all P > 0.05). CONCLUSIONS: The digital semi-rigid bridge SM fabricated with PEEK was clinically effective in maintaining the missing space and had advantages over the traditional band/crown loop SM. BioMed Central 2023-11-29 /pmc/articles/PMC10685679/ /pubmed/38031148 http://dx.doi.org/10.1186/s12903-023-03570-2 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Wang, Qi Zhang, Zhenzhen Zhong, Sheng Liu, Jiajia Hu, Ying Zhou, Ziling Zhang, Caidi Bai, Shizhu Wu, Li’an Clinical application of a digital semi-rigid bridge space maintainer fabricated from polyetheretherketone for premature loss of primary molars |
title | Clinical application of a digital semi-rigid bridge space maintainer fabricated from polyetheretherketone for premature loss of primary molars |
title_full | Clinical application of a digital semi-rigid bridge space maintainer fabricated from polyetheretherketone for premature loss of primary molars |
title_fullStr | Clinical application of a digital semi-rigid bridge space maintainer fabricated from polyetheretherketone for premature loss of primary molars |
title_full_unstemmed | Clinical application of a digital semi-rigid bridge space maintainer fabricated from polyetheretherketone for premature loss of primary molars |
title_short | Clinical application of a digital semi-rigid bridge space maintainer fabricated from polyetheretherketone for premature loss of primary molars |
title_sort | clinical application of a digital semi-rigid bridge space maintainer fabricated from polyetheretherketone for premature loss of primary molars |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10685679/ https://www.ncbi.nlm.nih.gov/pubmed/38031148 http://dx.doi.org/10.1186/s12903-023-03570-2 |
work_keys_str_mv | AT wangqi clinicalapplicationofadigitalsemirigidbridgespacemaintainerfabricatedfrompolyetheretherketoneforprematurelossofprimarymolars AT zhangzhenzhen clinicalapplicationofadigitalsemirigidbridgespacemaintainerfabricatedfrompolyetheretherketoneforprematurelossofprimarymolars AT zhongsheng clinicalapplicationofadigitalsemirigidbridgespacemaintainerfabricatedfrompolyetheretherketoneforprematurelossofprimarymolars AT liujiajia clinicalapplicationofadigitalsemirigidbridgespacemaintainerfabricatedfrompolyetheretherketoneforprematurelossofprimarymolars AT huying clinicalapplicationofadigitalsemirigidbridgespacemaintainerfabricatedfrompolyetheretherketoneforprematurelossofprimarymolars AT zhouziling clinicalapplicationofadigitalsemirigidbridgespacemaintainerfabricatedfrompolyetheretherketoneforprematurelossofprimarymolars AT zhangcaidi clinicalapplicationofadigitalsemirigidbridgespacemaintainerfabricatedfrompolyetheretherketoneforprematurelossofprimarymolars AT baishizhu clinicalapplicationofadigitalsemirigidbridgespacemaintainerfabricatedfrompolyetheretherketoneforprematurelossofprimarymolars AT wulian clinicalapplicationofadigitalsemirigidbridgespacemaintainerfabricatedfrompolyetheretherketoneforprematurelossofprimarymolars |