Cargando…

Reliability of International Normalized Ratio Results in the CoaguChek Pro II System in a Clinical Setting

The National Institute of Cardiology has previously used the CoaguChek(®) XS Plus system (Roche Diagnostics International Ltd), comparing capillary blood prothrombin time/international normalized ratio (PT/INR) results with those obtained using BCS-XP/Thromborel (Siemens). We assessed the reliabilit...

Descripción completa

Detalles Bibliográficos
Autores principales: Cortina-de-la-Rosa, Evelyn, Izaguirre-Ávila, Raúl, Ramírez-Hernández, Alejandro, Romero-Arroyo, María-Oliva, Cortés-Cortés, Karen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10686019/
https://www.ncbi.nlm.nih.gov/pubmed/38018118
http://dx.doi.org/10.1177/10760296231216451
_version_ 1785151733925675008
author Cortina-de-la-Rosa, Evelyn
Izaguirre-Ávila, Raúl
Ramírez-Hernández, Alejandro
Romero-Arroyo, María-Oliva
Cortés-Cortés, Karen
author_facet Cortina-de-la-Rosa, Evelyn
Izaguirre-Ávila, Raúl
Ramírez-Hernández, Alejandro
Romero-Arroyo, María-Oliva
Cortés-Cortés, Karen
author_sort Cortina-de-la-Rosa, Evelyn
collection PubMed
description The National Institute of Cardiology has previously used the CoaguChek(®) XS Plus system (Roche Diagnostics International Ltd), comparing capillary blood prothrombin time/international normalized ratio (PT/INR) results with those obtained using BCS-XP/Thromborel (Siemens). We assessed the reliability of PT/INR results using the third-generation CoaguChek Pro II system, the CoaguChek XS Plus system, and cobas(®) t 411 for citrated plasma analysis. Venous and capillary PT/INR were measured (N = 204). Spearman's correlation, Bland-Altman, and concordance analysis between methods were conducted. Spearman's correlation coefficients between venous/capillary INR were high for CoaguChek Pro II versus CoaguChek XS Plus (r = 0.994), CoaguChek Pro II versus cobas t 411 (r = 0.967), and CoaguChek XS Plus versus cobas t 411 (r = 0.968). Good concordance was observed among capillary methods (concordance coefficient [κ] = 0.888) and remaining relationships (P < .001 for all): cobas t 411 versus CoaguChek XS Plus (κ = 0.696) and cobas t 411 versus CoaguChek Pro II (κ = 0.684). In conclusion, good agreement was observed between CoaguChek Pro II, CoaguChek XS Plus, and cobas t 411.
format Online
Article
Text
id pubmed-10686019
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-106860192023-11-30 Reliability of International Normalized Ratio Results in the CoaguChek Pro II System in a Clinical Setting Cortina-de-la-Rosa, Evelyn Izaguirre-Ávila, Raúl Ramírez-Hernández, Alejandro Romero-Arroyo, María-Oliva Cortés-Cortés, Karen Clin Appl Thromb Hemost Original Manuscript The National Institute of Cardiology has previously used the CoaguChek(®) XS Plus system (Roche Diagnostics International Ltd), comparing capillary blood prothrombin time/international normalized ratio (PT/INR) results with those obtained using BCS-XP/Thromborel (Siemens). We assessed the reliability of PT/INR results using the third-generation CoaguChek Pro II system, the CoaguChek XS Plus system, and cobas(®) t 411 for citrated plasma analysis. Venous and capillary PT/INR were measured (N = 204). Spearman's correlation, Bland-Altman, and concordance analysis between methods were conducted. Spearman's correlation coefficients between venous/capillary INR were high for CoaguChek Pro II versus CoaguChek XS Plus (r = 0.994), CoaguChek Pro II versus cobas t 411 (r = 0.967), and CoaguChek XS Plus versus cobas t 411 (r = 0.968). Good concordance was observed among capillary methods (concordance coefficient [κ] = 0.888) and remaining relationships (P < .001 for all): cobas t 411 versus CoaguChek XS Plus (κ = 0.696) and cobas t 411 versus CoaguChek Pro II (κ = 0.684). In conclusion, good agreement was observed between CoaguChek Pro II, CoaguChek XS Plus, and cobas t 411. SAGE Publications 2023-11-28 /pmc/articles/PMC10686019/ /pubmed/38018118 http://dx.doi.org/10.1177/10760296231216451 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Manuscript
Cortina-de-la-Rosa, Evelyn
Izaguirre-Ávila, Raúl
Ramírez-Hernández, Alejandro
Romero-Arroyo, María-Oliva
Cortés-Cortés, Karen
Reliability of International Normalized Ratio Results in the CoaguChek Pro II System in a Clinical Setting
title Reliability of International Normalized Ratio Results in the CoaguChek Pro II System in a Clinical Setting
title_full Reliability of International Normalized Ratio Results in the CoaguChek Pro II System in a Clinical Setting
title_fullStr Reliability of International Normalized Ratio Results in the CoaguChek Pro II System in a Clinical Setting
title_full_unstemmed Reliability of International Normalized Ratio Results in the CoaguChek Pro II System in a Clinical Setting
title_short Reliability of International Normalized Ratio Results in the CoaguChek Pro II System in a Clinical Setting
title_sort reliability of international normalized ratio results in the coaguchek pro ii system in a clinical setting
topic Original Manuscript
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10686019/
https://www.ncbi.nlm.nih.gov/pubmed/38018118
http://dx.doi.org/10.1177/10760296231216451
work_keys_str_mv AT cortinadelarosaevelyn reliabilityofinternationalnormalizedratioresultsinthecoaguchekproiisysteminaclinicalsetting
AT izaguirreavilaraul reliabilityofinternationalnormalizedratioresultsinthecoaguchekproiisysteminaclinicalsetting
AT ramirezhernandezalejandro reliabilityofinternationalnormalizedratioresultsinthecoaguchekproiisysteminaclinicalsetting
AT romeroarroyomariaoliva reliabilityofinternationalnormalizedratioresultsinthecoaguchekproiisysteminaclinicalsetting
AT cortescorteskaren reliabilityofinternationalnormalizedratioresultsinthecoaguchekproiisysteminaclinicalsetting