Cargando…
Reliability of International Normalized Ratio Results in the CoaguChek Pro II System in a Clinical Setting
The National Institute of Cardiology has previously used the CoaguChek(®) XS Plus system (Roche Diagnostics International Ltd), comparing capillary blood prothrombin time/international normalized ratio (PT/INR) results with those obtained using BCS-XP/Thromborel (Siemens). We assessed the reliabilit...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10686019/ https://www.ncbi.nlm.nih.gov/pubmed/38018118 http://dx.doi.org/10.1177/10760296231216451 |
_version_ | 1785151733925675008 |
---|---|
author | Cortina-de-la-Rosa, Evelyn Izaguirre-Ávila, Raúl Ramírez-Hernández, Alejandro Romero-Arroyo, María-Oliva Cortés-Cortés, Karen |
author_facet | Cortina-de-la-Rosa, Evelyn Izaguirre-Ávila, Raúl Ramírez-Hernández, Alejandro Romero-Arroyo, María-Oliva Cortés-Cortés, Karen |
author_sort | Cortina-de-la-Rosa, Evelyn |
collection | PubMed |
description | The National Institute of Cardiology has previously used the CoaguChek(®) XS Plus system (Roche Diagnostics International Ltd), comparing capillary blood prothrombin time/international normalized ratio (PT/INR) results with those obtained using BCS-XP/Thromborel (Siemens). We assessed the reliability of PT/INR results using the third-generation CoaguChek Pro II system, the CoaguChek XS Plus system, and cobas(®) t 411 for citrated plasma analysis. Venous and capillary PT/INR were measured (N = 204). Spearman's correlation, Bland-Altman, and concordance analysis between methods were conducted. Spearman's correlation coefficients between venous/capillary INR were high for CoaguChek Pro II versus CoaguChek XS Plus (r = 0.994), CoaguChek Pro II versus cobas t 411 (r = 0.967), and CoaguChek XS Plus versus cobas t 411 (r = 0.968). Good concordance was observed among capillary methods (concordance coefficient [κ] = 0.888) and remaining relationships (P < .001 for all): cobas t 411 versus CoaguChek XS Plus (κ = 0.696) and cobas t 411 versus CoaguChek Pro II (κ = 0.684). In conclusion, good agreement was observed between CoaguChek Pro II, CoaguChek XS Plus, and cobas t 411. |
format | Online Article Text |
id | pubmed-10686019 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-106860192023-11-30 Reliability of International Normalized Ratio Results in the CoaguChek Pro II System in a Clinical Setting Cortina-de-la-Rosa, Evelyn Izaguirre-Ávila, Raúl Ramírez-Hernández, Alejandro Romero-Arroyo, María-Oliva Cortés-Cortés, Karen Clin Appl Thromb Hemost Original Manuscript The National Institute of Cardiology has previously used the CoaguChek(®) XS Plus system (Roche Diagnostics International Ltd), comparing capillary blood prothrombin time/international normalized ratio (PT/INR) results with those obtained using BCS-XP/Thromborel (Siemens). We assessed the reliability of PT/INR results using the third-generation CoaguChek Pro II system, the CoaguChek XS Plus system, and cobas(®) t 411 for citrated plasma analysis. Venous and capillary PT/INR were measured (N = 204). Spearman's correlation, Bland-Altman, and concordance analysis between methods were conducted. Spearman's correlation coefficients between venous/capillary INR were high for CoaguChek Pro II versus CoaguChek XS Plus (r = 0.994), CoaguChek Pro II versus cobas t 411 (r = 0.967), and CoaguChek XS Plus versus cobas t 411 (r = 0.968). Good concordance was observed among capillary methods (concordance coefficient [κ] = 0.888) and remaining relationships (P < .001 for all): cobas t 411 versus CoaguChek XS Plus (κ = 0.696) and cobas t 411 versus CoaguChek Pro II (κ = 0.684). In conclusion, good agreement was observed between CoaguChek Pro II, CoaguChek XS Plus, and cobas t 411. SAGE Publications 2023-11-28 /pmc/articles/PMC10686019/ /pubmed/38018118 http://dx.doi.org/10.1177/10760296231216451 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Original Manuscript Cortina-de-la-Rosa, Evelyn Izaguirre-Ávila, Raúl Ramírez-Hernández, Alejandro Romero-Arroyo, María-Oliva Cortés-Cortés, Karen Reliability of International Normalized Ratio Results in the CoaguChek Pro II System in a Clinical Setting |
title | Reliability of International Normalized Ratio Results in the CoaguChek Pro II System in a Clinical Setting |
title_full | Reliability of International Normalized Ratio Results in the CoaguChek Pro II System in a Clinical Setting |
title_fullStr | Reliability of International Normalized Ratio Results in the CoaguChek Pro II System in a Clinical Setting |
title_full_unstemmed | Reliability of International Normalized Ratio Results in the CoaguChek Pro II System in a Clinical Setting |
title_short | Reliability of International Normalized Ratio Results in the CoaguChek Pro II System in a Clinical Setting |
title_sort | reliability of international normalized ratio results in the coaguchek pro ii system in a clinical setting |
topic | Original Manuscript |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10686019/ https://www.ncbi.nlm.nih.gov/pubmed/38018118 http://dx.doi.org/10.1177/10760296231216451 |
work_keys_str_mv | AT cortinadelarosaevelyn reliabilityofinternationalnormalizedratioresultsinthecoaguchekproiisysteminaclinicalsetting AT izaguirreavilaraul reliabilityofinternationalnormalizedratioresultsinthecoaguchekproiisysteminaclinicalsetting AT ramirezhernandezalejandro reliabilityofinternationalnormalizedratioresultsinthecoaguchekproiisysteminaclinicalsetting AT romeroarroyomariaoliva reliabilityofinternationalnormalizedratioresultsinthecoaguchekproiisysteminaclinicalsetting AT cortescorteskaren reliabilityofinternationalnormalizedratioresultsinthecoaguchekproiisysteminaclinicalsetting |