Cargando…
Biomechanical analysis of bridge combined fixation system as a novel treatment for the fixation of type A3 distal femoral fractures
BACKGROUND: To compare the biomechanical parameters of AO/OTA type A3 distal femoral fractures fixed bilaterally with a bridge combined fixation system (BCFS) and lateral locking compression plate + locking reconstruction plate (LCP + LRP). METHODS: Twelve A3 distal femoral fracture models with medi...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10687203/ https://www.ncbi.nlm.nih.gov/pubmed/38033528 http://dx.doi.org/10.3389/fsurg.2023.1264904 |
_version_ | 1785151932843687936 |
---|---|
author | Liu, Jianke Huang, Zhaozhao Qi, Yubin Long, Yuntao Zhang, Yanhui Liu, Na Zuo, Guilai Wang, Wen |
author_facet | Liu, Jianke Huang, Zhaozhao Qi, Yubin Long, Yuntao Zhang, Yanhui Liu, Na Zuo, Guilai Wang, Wen |
author_sort | Liu, Jianke |
collection | PubMed |
description | BACKGROUND: To compare the biomechanical parameters of AO/OTA type A3 distal femoral fractures fixed bilaterally with a bridge combined fixation system (BCFS) and lateral locking compression plate + locking reconstruction plate (LCP + LRP). METHODS: Twelve A3 distal femoral fracture models with medial cortical defects of the distal femur were created using synthetic femoral Sawbones. BCFS and LCP + LRP were used for bilateral fixation, with six in each group. Axial compression and torsion tests were performed on the two groups of fracture models to determine their stiffness during axial compression and the Torsional stiffness during torsion tests. Axial compression failure tests were performed to collect the vertical loads of the ultimate failure tests. RESULTS: In the test conducted on the fixed type A3 distal femoral fracture models, the axial stiffness in the BCFS group (group A) (1,072.61 ± 113.5 N/mm) was not significantly different from that in the LCP + LRP group (group B) (1,184.13 ± 110.24 N/mm) (t = 1.726, P = 0.115), the Torsional stiffness in group A (3.73 ± 0.12 N.m/deg) was higher than that in group B (3.37 ± 0.04 N.m/deg) (t = 6.825, P < 0.001),and the ultimate failure test of type A3 fracture model showed that the vertical load to destroy group A fixation (5,290.45 ± 109.63 N) was higher than that for group B (3,978.43 ± 17.1 N) (t = 23.28, P < 0.05). Notably, intertrochanteric fractures occurred in groups A and B. CONCLUSIONS: In the fixation of type A3 distal femoral fractures, the anti-axial compression of the BCFS group was similar to that of the LCP + LRP group, but the anti-torsion was better. |
format | Online Article Text |
id | pubmed-10687203 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-106872032023-11-30 Biomechanical analysis of bridge combined fixation system as a novel treatment for the fixation of type A3 distal femoral fractures Liu, Jianke Huang, Zhaozhao Qi, Yubin Long, Yuntao Zhang, Yanhui Liu, Na Zuo, Guilai Wang, Wen Front Surg Surgery BACKGROUND: To compare the biomechanical parameters of AO/OTA type A3 distal femoral fractures fixed bilaterally with a bridge combined fixation system (BCFS) and lateral locking compression plate + locking reconstruction plate (LCP + LRP). METHODS: Twelve A3 distal femoral fracture models with medial cortical defects of the distal femur were created using synthetic femoral Sawbones. BCFS and LCP + LRP were used for bilateral fixation, with six in each group. Axial compression and torsion tests were performed on the two groups of fracture models to determine their stiffness during axial compression and the Torsional stiffness during torsion tests. Axial compression failure tests were performed to collect the vertical loads of the ultimate failure tests. RESULTS: In the test conducted on the fixed type A3 distal femoral fracture models, the axial stiffness in the BCFS group (group A) (1,072.61 ± 113.5 N/mm) was not significantly different from that in the LCP + LRP group (group B) (1,184.13 ± 110.24 N/mm) (t = 1.726, P = 0.115), the Torsional stiffness in group A (3.73 ± 0.12 N.m/deg) was higher than that in group B (3.37 ± 0.04 N.m/deg) (t = 6.825, P < 0.001),and the ultimate failure test of type A3 fracture model showed that the vertical load to destroy group A fixation (5,290.45 ± 109.63 N) was higher than that for group B (3,978.43 ± 17.1 N) (t = 23.28, P < 0.05). Notably, intertrochanteric fractures occurred in groups A and B. CONCLUSIONS: In the fixation of type A3 distal femoral fractures, the anti-axial compression of the BCFS group was similar to that of the LCP + LRP group, but the anti-torsion was better. Frontiers Media S.A. 2023-11-16 /pmc/articles/PMC10687203/ /pubmed/38033528 http://dx.doi.org/10.3389/fsurg.2023.1264904 Text en © 2023 Liu, Huang, Qi, Long, Zhang, Liu, Zuo and Wang. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY) (https://creativecommons.org/licenses/by/4.0/) . The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Surgery Liu, Jianke Huang, Zhaozhao Qi, Yubin Long, Yuntao Zhang, Yanhui Liu, Na Zuo, Guilai Wang, Wen Biomechanical analysis of bridge combined fixation system as a novel treatment for the fixation of type A3 distal femoral fractures |
title | Biomechanical analysis of bridge combined fixation system as a novel treatment for the fixation of type A3 distal femoral fractures |
title_full | Biomechanical analysis of bridge combined fixation system as a novel treatment for the fixation of type A3 distal femoral fractures |
title_fullStr | Biomechanical analysis of bridge combined fixation system as a novel treatment for the fixation of type A3 distal femoral fractures |
title_full_unstemmed | Biomechanical analysis of bridge combined fixation system as a novel treatment for the fixation of type A3 distal femoral fractures |
title_short | Biomechanical analysis of bridge combined fixation system as a novel treatment for the fixation of type A3 distal femoral fractures |
title_sort | biomechanical analysis of bridge combined fixation system as a novel treatment for the fixation of type a3 distal femoral fractures |
topic | Surgery |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10687203/ https://www.ncbi.nlm.nih.gov/pubmed/38033528 http://dx.doi.org/10.3389/fsurg.2023.1264904 |
work_keys_str_mv | AT liujianke biomechanicalanalysisofbridgecombinedfixationsystemasanoveltreatmentforthefixationoftypea3distalfemoralfractures AT huangzhaozhao biomechanicalanalysisofbridgecombinedfixationsystemasanoveltreatmentforthefixationoftypea3distalfemoralfractures AT qiyubin biomechanicalanalysisofbridgecombinedfixationsystemasanoveltreatmentforthefixationoftypea3distalfemoralfractures AT longyuntao biomechanicalanalysisofbridgecombinedfixationsystemasanoveltreatmentforthefixationoftypea3distalfemoralfractures AT zhangyanhui biomechanicalanalysisofbridgecombinedfixationsystemasanoveltreatmentforthefixationoftypea3distalfemoralfractures AT liuna biomechanicalanalysisofbridgecombinedfixationsystemasanoveltreatmentforthefixationoftypea3distalfemoralfractures AT zuoguilai biomechanicalanalysisofbridgecombinedfixationsystemasanoveltreatmentforthefixationoftypea3distalfemoralfractures AT wangwen biomechanicalanalysisofbridgecombinedfixationsystemasanoveltreatmentforthefixationoftypea3distalfemoralfractures |