Cargando…

Biomechanical analysis of bridge combined fixation system as a novel treatment for the fixation of type A3 distal femoral fractures

BACKGROUND: To compare the biomechanical parameters of AO/OTA type A3 distal femoral fractures fixed bilaterally with a bridge combined fixation system (BCFS) and lateral locking compression plate + locking reconstruction plate (LCP + LRP). METHODS: Twelve A3 distal femoral fracture models with medi...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Jianke, Huang, Zhaozhao, Qi, Yubin, Long, Yuntao, Zhang, Yanhui, Liu, Na, Zuo, Guilai, Wang, Wen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10687203/
https://www.ncbi.nlm.nih.gov/pubmed/38033528
http://dx.doi.org/10.3389/fsurg.2023.1264904
_version_ 1785151932843687936
author Liu, Jianke
Huang, Zhaozhao
Qi, Yubin
Long, Yuntao
Zhang, Yanhui
Liu, Na
Zuo, Guilai
Wang, Wen
author_facet Liu, Jianke
Huang, Zhaozhao
Qi, Yubin
Long, Yuntao
Zhang, Yanhui
Liu, Na
Zuo, Guilai
Wang, Wen
author_sort Liu, Jianke
collection PubMed
description BACKGROUND: To compare the biomechanical parameters of AO/OTA type A3 distal femoral fractures fixed bilaterally with a bridge combined fixation system (BCFS) and lateral locking compression plate + locking reconstruction plate (LCP + LRP). METHODS: Twelve A3 distal femoral fracture models with medial cortical defects of the distal femur were created using synthetic femoral Sawbones. BCFS and LCP + LRP were used for bilateral fixation, with six in each group. Axial compression and torsion tests were performed on the two groups of fracture models to determine their stiffness during axial compression and the Torsional stiffness during torsion tests. Axial compression failure tests were performed to collect the vertical loads of the ultimate failure tests. RESULTS: In the test conducted on the fixed type A3 distal femoral fracture models, the axial stiffness in the BCFS group (group A) (1,072.61 ± 113.5 N/mm) was not significantly different from that in the LCP + LRP group (group B) (1,184.13 ± 110.24 N/mm) (t = 1.726, P = 0.115), the Torsional stiffness in group A (3.73 ± 0.12 N.m/deg) was higher than that in group B (3.37 ± 0.04 N.m/deg) (t = 6.825, P < 0.001),and the ultimate failure test of type A3 fracture model showed that the vertical load to destroy group A fixation (5,290.45 ± 109.63 N) was higher than that for group B (3,978.43 ± 17.1 N) (t = 23.28, P < 0.05). Notably, intertrochanteric fractures occurred in groups A and B. CONCLUSIONS: In the fixation of type A3 distal femoral fractures, the anti-axial compression of the BCFS group was similar to that of the LCP + LRP group, but the anti-torsion was better.
format Online
Article
Text
id pubmed-10687203
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-106872032023-11-30 Biomechanical analysis of bridge combined fixation system as a novel treatment for the fixation of type A3 distal femoral fractures Liu, Jianke Huang, Zhaozhao Qi, Yubin Long, Yuntao Zhang, Yanhui Liu, Na Zuo, Guilai Wang, Wen Front Surg Surgery BACKGROUND: To compare the biomechanical parameters of AO/OTA type A3 distal femoral fractures fixed bilaterally with a bridge combined fixation system (BCFS) and lateral locking compression plate + locking reconstruction plate (LCP + LRP). METHODS: Twelve A3 distal femoral fracture models with medial cortical defects of the distal femur were created using synthetic femoral Sawbones. BCFS and LCP + LRP were used for bilateral fixation, with six in each group. Axial compression and torsion tests were performed on the two groups of fracture models to determine their stiffness during axial compression and the Torsional stiffness during torsion tests. Axial compression failure tests were performed to collect the vertical loads of the ultimate failure tests. RESULTS: In the test conducted on the fixed type A3 distal femoral fracture models, the axial stiffness in the BCFS group (group A) (1,072.61 ± 113.5 N/mm) was not significantly different from that in the LCP + LRP group (group B) (1,184.13 ± 110.24 N/mm) (t = 1.726, P = 0.115), the Torsional stiffness in group A (3.73 ± 0.12 N.m/deg) was higher than that in group B (3.37 ± 0.04 N.m/deg) (t = 6.825, P < 0.001),and the ultimate failure test of type A3 fracture model showed that the vertical load to destroy group A fixation (5,290.45 ± 109.63 N) was higher than that for group B (3,978.43 ± 17.1 N) (t = 23.28, P < 0.05). Notably, intertrochanteric fractures occurred in groups A and B. CONCLUSIONS: In the fixation of type A3 distal femoral fractures, the anti-axial compression of the BCFS group was similar to that of the LCP + LRP group, but the anti-torsion was better. Frontiers Media S.A. 2023-11-16 /pmc/articles/PMC10687203/ /pubmed/38033528 http://dx.doi.org/10.3389/fsurg.2023.1264904 Text en © 2023 Liu, Huang, Qi, Long, Zhang, Liu, Zuo and Wang. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY) (https://creativecommons.org/licenses/by/4.0/) . The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Surgery
Liu, Jianke
Huang, Zhaozhao
Qi, Yubin
Long, Yuntao
Zhang, Yanhui
Liu, Na
Zuo, Guilai
Wang, Wen
Biomechanical analysis of bridge combined fixation system as a novel treatment for the fixation of type A3 distal femoral fractures
title Biomechanical analysis of bridge combined fixation system as a novel treatment for the fixation of type A3 distal femoral fractures
title_full Biomechanical analysis of bridge combined fixation system as a novel treatment for the fixation of type A3 distal femoral fractures
title_fullStr Biomechanical analysis of bridge combined fixation system as a novel treatment for the fixation of type A3 distal femoral fractures
title_full_unstemmed Biomechanical analysis of bridge combined fixation system as a novel treatment for the fixation of type A3 distal femoral fractures
title_short Biomechanical analysis of bridge combined fixation system as a novel treatment for the fixation of type A3 distal femoral fractures
title_sort biomechanical analysis of bridge combined fixation system as a novel treatment for the fixation of type a3 distal femoral fractures
topic Surgery
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10687203/
https://www.ncbi.nlm.nih.gov/pubmed/38033528
http://dx.doi.org/10.3389/fsurg.2023.1264904
work_keys_str_mv AT liujianke biomechanicalanalysisofbridgecombinedfixationsystemasanoveltreatmentforthefixationoftypea3distalfemoralfractures
AT huangzhaozhao biomechanicalanalysisofbridgecombinedfixationsystemasanoveltreatmentforthefixationoftypea3distalfemoralfractures
AT qiyubin biomechanicalanalysisofbridgecombinedfixationsystemasanoveltreatmentforthefixationoftypea3distalfemoralfractures
AT longyuntao biomechanicalanalysisofbridgecombinedfixationsystemasanoveltreatmentforthefixationoftypea3distalfemoralfractures
AT zhangyanhui biomechanicalanalysisofbridgecombinedfixationsystemasanoveltreatmentforthefixationoftypea3distalfemoralfractures
AT liuna biomechanicalanalysisofbridgecombinedfixationsystemasanoveltreatmentforthefixationoftypea3distalfemoralfractures
AT zuoguilai biomechanicalanalysisofbridgecombinedfixationsystemasanoveltreatmentforthefixationoftypea3distalfemoralfractures
AT wangwen biomechanicalanalysisofbridgecombinedfixationsystemasanoveltreatmentforthefixationoftypea3distalfemoralfractures