Cargando…
Possible Delayed Foreign Body Reactions against Titanium Clips and Coating Materials after Unruptured Cerebral Aneurysm Surgery
Delayed foreign body reactions to either or both clipping and coating materials have been reported in several small series; however, studies in the titanium clip era are scarce. This study aims to survey the contemporary status of such reactions to titanium clips and coating materials. Among patient...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Japan Neurosurgical Society
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10687670/ https://www.ncbi.nlm.nih.gov/pubmed/37648536 http://dx.doi.org/10.2176/jns-nmc.2023-0116 |
Sumario: | Delayed foreign body reactions to either or both clipping and coating materials have been reported in several small series; however, studies in the titanium clip era are scarce. This study aims to survey the contemporary status of such reactions to titanium clips and coating materials. Among patients who received a total of 2327 unruptured cerebral aneurysmal surgeries, 12 developed delayed intraparenchymal reactions during outpatient magnetic resonance imaging (MRI) follow-up. A retrospective investigation was conducted. The patients' average age was 58.6 (45-73) years, and 11 were women. The aneurysms were located in the middle cerebral artery (n = 7), internal carotid artery (n = 4), or anterior communicating artery (AComA, n = 1). In 10 patients, additional coating with tiny cotton fragments was applied to the residual neck after clipping with titanium clips; however, only the clipping with titanium clips was performed in the remaining two. The median time from surgery to diagnosis was 4.5 (0.3-60) months. Seven (58.3%) patients were asymptomatic, and three developed neurological deficits. MRI findings were characterized by a solid- or rim-enhancing lobulated mass adjacent to the clip with surrounding parenchymal edema. In 11 patients, the lesions reduced in size or disappeared; however, in one patient, an AComA aneurysm was exacerbated, necessitating its removal along with optic nerve decompression. In conclusion, cotton material is a strongly suspected cause of delayed foreign body reactions, and although extremely rare, titanium clips alone may also induce such a reaction. The prognosis is relatively good with steroid therapy; however, caution is required when the aneurysm is close to the optic nerve, as in AComA aneurysms. |
---|