Cargando…

Intraoral Scan Accuracy and Time Efficiency in Implant-Supported Fixed Partial Dentures: A Systematic Review

The digital implant impression technique (DIT) and conventional implant impression technique (CIT) workflows in implant-supported fixed partial dentures (FPDs) have not been extensively compared in prior studies. Moreover, there is no agreement on the more accurate method that entails less time in t...

Descripción completa

Detalles Bibliográficos
Autores principales: Pullishery, Fawaz, Huraib, Wayel, Alruhaymi, Abdullah S, Alharandah, Wabel Abdulrahman, AlDara, Elaf Waleed, Benten, Muath Mohammed, Alassaf, Dina Mansour, Babatin, Wafa Mohammed A, Mohsen, Nagam Mohammed M
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10688193/
https://www.ncbi.nlm.nih.gov/pubmed/38034200
http://dx.doi.org/10.7759/cureus.48027
_version_ 1785152133007409152
author Pullishery, Fawaz
Huraib, Wayel
Alruhaymi, Abdullah S
Alharandah, Wabel Abdulrahman
AlDara, Elaf Waleed
Benten, Muath Mohammed
Alassaf, Dina Mansour
Babatin, Wafa Mohammed A
Mohsen, Nagam Mohammed M
author_facet Pullishery, Fawaz
Huraib, Wayel
Alruhaymi, Abdullah S
Alharandah, Wabel Abdulrahman
AlDara, Elaf Waleed
Benten, Muath Mohammed
Alassaf, Dina Mansour
Babatin, Wafa Mohammed A
Mohsen, Nagam Mohammed M
author_sort Pullishery, Fawaz
collection PubMed
description The digital implant impression technique (DIT) and conventional implant impression technique (CIT) workflows in implant-supported fixed partial dentures (FPDs) have not been extensively compared in prior studies. Moreover, there is no agreement on the more accurate method that entails less time in the laboratory and during the clinical phases of fabrication and delivery of the prosthesis, respectively. This review aimed to assess the precision of the imaging procedure and overall fabrication time of the DIT and CIT for the implant-supported FPDs. An electronic search was performed using PubMed, Scopus, EMBASE, Cochrane Oral Health Group, and Dentistry and Oral Science Source databases through EBSCO for relevant studies from January 2014 to April 2023. Following the preliminary screening, the studies that met the inclusion criteria underwent full-text review in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The Cochrane Collaboration risk of bias appraisal tool and Newcastle-Ottawa scale were applied to assess the quality of randomized controlled trials (RCTs) and non-randomized prospective clinical studies, respectively. The initial search yielded 332 studies, and after excluding duplicates, 241 papers were available for screening. Titles and abstracts were reviewed, and 97 articles were chosen for full-text review by two authors independently. Furthermore, 89 articles were excluded in compliance with the PICOS question, and eight studies were chosen for qualitative analysis. Hence, the review comprised two RCTs and six prospective clinical studies. The time efficiency of the implant-supported FPDs was examined in four investigations, three of which used the Trios 3 scanner and one used the Intero scanner. The three-dimensional accuracy of DIT and CIT was compared in six clinical comparative studies. One of the RCTs was rated to have a high risk of bias and the other with a moderate quality of evidence. The six prospective studies were rated to have high-quality of evidence. The findings of this review indicate the prospective applicability of future intraoral scanning systems. The DIT was reported to be outstanding in terms of patient preferences and total fabrication time efficiency. Additional in vivo studies are needed to establish the therapeutic usefulness and time efficiency of integrating DIT in more comprehensive settings.
format Online
Article
Text
id pubmed-10688193
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-106881932023-11-30 Intraoral Scan Accuracy and Time Efficiency in Implant-Supported Fixed Partial Dentures: A Systematic Review Pullishery, Fawaz Huraib, Wayel Alruhaymi, Abdullah S Alharandah, Wabel Abdulrahman AlDara, Elaf Waleed Benten, Muath Mohammed Alassaf, Dina Mansour Babatin, Wafa Mohammed A Mohsen, Nagam Mohammed M Cureus Dentistry The digital implant impression technique (DIT) and conventional implant impression technique (CIT) workflows in implant-supported fixed partial dentures (FPDs) have not been extensively compared in prior studies. Moreover, there is no agreement on the more accurate method that entails less time in the laboratory and during the clinical phases of fabrication and delivery of the prosthesis, respectively. This review aimed to assess the precision of the imaging procedure and overall fabrication time of the DIT and CIT for the implant-supported FPDs. An electronic search was performed using PubMed, Scopus, EMBASE, Cochrane Oral Health Group, and Dentistry and Oral Science Source databases through EBSCO for relevant studies from January 2014 to April 2023. Following the preliminary screening, the studies that met the inclusion criteria underwent full-text review in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The Cochrane Collaboration risk of bias appraisal tool and Newcastle-Ottawa scale were applied to assess the quality of randomized controlled trials (RCTs) and non-randomized prospective clinical studies, respectively. The initial search yielded 332 studies, and after excluding duplicates, 241 papers were available for screening. Titles and abstracts were reviewed, and 97 articles were chosen for full-text review by two authors independently. Furthermore, 89 articles were excluded in compliance with the PICOS question, and eight studies were chosen for qualitative analysis. Hence, the review comprised two RCTs and six prospective clinical studies. The time efficiency of the implant-supported FPDs was examined in four investigations, three of which used the Trios 3 scanner and one used the Intero scanner. The three-dimensional accuracy of DIT and CIT was compared in six clinical comparative studies. One of the RCTs was rated to have a high risk of bias and the other with a moderate quality of evidence. The six prospective studies were rated to have high-quality of evidence. The findings of this review indicate the prospective applicability of future intraoral scanning systems. The DIT was reported to be outstanding in terms of patient preferences and total fabrication time efficiency. Additional in vivo studies are needed to establish the therapeutic usefulness and time efficiency of integrating DIT in more comprehensive settings. Cureus 2023-10-31 /pmc/articles/PMC10688193/ /pubmed/38034200 http://dx.doi.org/10.7759/cureus.48027 Text en Copyright © 2023, Pullishery et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Dentistry
Pullishery, Fawaz
Huraib, Wayel
Alruhaymi, Abdullah S
Alharandah, Wabel Abdulrahman
AlDara, Elaf Waleed
Benten, Muath Mohammed
Alassaf, Dina Mansour
Babatin, Wafa Mohammed A
Mohsen, Nagam Mohammed M
Intraoral Scan Accuracy and Time Efficiency in Implant-Supported Fixed Partial Dentures: A Systematic Review
title Intraoral Scan Accuracy and Time Efficiency in Implant-Supported Fixed Partial Dentures: A Systematic Review
title_full Intraoral Scan Accuracy and Time Efficiency in Implant-Supported Fixed Partial Dentures: A Systematic Review
title_fullStr Intraoral Scan Accuracy and Time Efficiency in Implant-Supported Fixed Partial Dentures: A Systematic Review
title_full_unstemmed Intraoral Scan Accuracy and Time Efficiency in Implant-Supported Fixed Partial Dentures: A Systematic Review
title_short Intraoral Scan Accuracy and Time Efficiency in Implant-Supported Fixed Partial Dentures: A Systematic Review
title_sort intraoral scan accuracy and time efficiency in implant-supported fixed partial dentures: a systematic review
topic Dentistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10688193/
https://www.ncbi.nlm.nih.gov/pubmed/38034200
http://dx.doi.org/10.7759/cureus.48027
work_keys_str_mv AT pullisheryfawaz intraoralscanaccuracyandtimeefficiencyinimplantsupportedfixedpartialdenturesasystematicreview
AT huraibwayel intraoralscanaccuracyandtimeefficiencyinimplantsupportedfixedpartialdenturesasystematicreview
AT alruhaymiabdullahs intraoralscanaccuracyandtimeefficiencyinimplantsupportedfixedpartialdenturesasystematicreview
AT alharandahwabelabdulrahman intraoralscanaccuracyandtimeefficiencyinimplantsupportedfixedpartialdenturesasystematicreview
AT aldaraelafwaleed intraoralscanaccuracyandtimeefficiencyinimplantsupportedfixedpartialdenturesasystematicreview
AT bentenmuathmohammed intraoralscanaccuracyandtimeefficiencyinimplantsupportedfixedpartialdenturesasystematicreview
AT alassafdinamansour intraoralscanaccuracyandtimeefficiencyinimplantsupportedfixedpartialdenturesasystematicreview
AT babatinwafamohammeda intraoralscanaccuracyandtimeefficiencyinimplantsupportedfixedpartialdenturesasystematicreview
AT mohsennagammohammedm intraoralscanaccuracyandtimeefficiencyinimplantsupportedfixedpartialdenturesasystematicreview