Cargando…
A low-dose biplanar X-ray imager has RSA level precision in total knee arthroplasty
BACKGROUND AND PURPOSE: The low radiation biplanar X-ray imager (EOS imaging, Paris, France) scans patients in a weight-bearing position, provides calibrated images, and limits radiation, an asset for serial radiostereometric analysis (RSA) studies. RSA in vivo precision values have not been publish...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medical Journals Sweden, on behalf of the Nordic Orthopedic Federation
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10688435/ https://www.ncbi.nlm.nih.gov/pubmed/38032252 http://dx.doi.org/10.2340/17453674.2023.19669 |
_version_ | 1785152170716299264 |
---|---|
author | HURRY, Jennifer K SPURWAY, Alan J LAENDE, Elise K REHAN, Saad ASTEPHEN WILSON, Janie L DUNBAR, Michael J EL-HAWARY, Ron |
author_facet | HURRY, Jennifer K SPURWAY, Alan J LAENDE, Elise K REHAN, Saad ASTEPHEN WILSON, Janie L DUNBAR, Michael J EL-HAWARY, Ron |
author_sort | HURRY, Jennifer K |
collection | PubMed |
description | BACKGROUND AND PURPOSE: The low radiation biplanar X-ray imager (EOS imaging, Paris, France) scans patients in a weight-bearing position, provides calibrated images, and limits radiation, an asset for serial radiostereometric analysis (RSA) studies. RSA in vivo precision values have not been published for this type of imaging system, thus the goal of this study was to assess the precision of RSA in vivo utilizing a low radiation biplanar imager. PATIENTS AND METHODS: At a mean of 5 years post-surgery (range 1.4–7.5 years), 15 total knee arthroplasty (TKA) participants (mean age 67 years at the time of imaging, 12 female, 3 male) with RSA markers implanted during index surgery were scanned twice at the same visit in the EOS imager. Precision of marker-based analysis was calculated by comparing the position of the implant relative to the underlying bone between the 2 examinations. RESULTS: The 95% limit of precision was 0.11, 0.04, and 0.15 mm along the x, y, and z axes, respectively and 0.15°, 0.20°, and 0.14° around the same axes. CONCLUSION: This precision study has shown an in vivo RSA precision of ≤ 0.15 mm and ≤ 0.20°, well within published uniplanar values for conventional arthroplasty RSA, with the added benefit of weight-bearing imaging, a lower radiation dose, and without the need for a reference object during the scan. |
format | Online Article Text |
id | pubmed-10688435 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Medical Journals Sweden, on behalf of the Nordic Orthopedic Federation |
record_format | MEDLINE/PubMed |
spelling | pubmed-106884352023-11-30 A low-dose biplanar X-ray imager has RSA level precision in total knee arthroplasty HURRY, Jennifer K SPURWAY, Alan J LAENDE, Elise K REHAN, Saad ASTEPHEN WILSON, Janie L DUNBAR, Michael J EL-HAWARY, Ron Acta Orthop Article BACKGROUND AND PURPOSE: The low radiation biplanar X-ray imager (EOS imaging, Paris, France) scans patients in a weight-bearing position, provides calibrated images, and limits radiation, an asset for serial radiostereometric analysis (RSA) studies. RSA in vivo precision values have not been published for this type of imaging system, thus the goal of this study was to assess the precision of RSA in vivo utilizing a low radiation biplanar imager. PATIENTS AND METHODS: At a mean of 5 years post-surgery (range 1.4–7.5 years), 15 total knee arthroplasty (TKA) participants (mean age 67 years at the time of imaging, 12 female, 3 male) with RSA markers implanted during index surgery were scanned twice at the same visit in the EOS imager. Precision of marker-based analysis was calculated by comparing the position of the implant relative to the underlying bone between the 2 examinations. RESULTS: The 95% limit of precision was 0.11, 0.04, and 0.15 mm along the x, y, and z axes, respectively and 0.15°, 0.20°, and 0.14° around the same axes. CONCLUSION: This precision study has shown an in vivo RSA precision of ≤ 0.15 mm and ≤ 0.20°, well within published uniplanar values for conventional arthroplasty RSA, with the added benefit of weight-bearing imaging, a lower radiation dose, and without the need for a reference object during the scan. Medical Journals Sweden, on behalf of the Nordic Orthopedic Federation 2023-11-30 /pmc/articles/PMC10688435/ /pubmed/38032252 http://dx.doi.org/10.2340/17453674.2023.19669 Text en © 2023 The Author(s) https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (https://creativecommons.org/licenses/by-nc/4.0/), allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material for non-commercial purposes, provided proper attribution to the original work. |
spellingShingle | Article HURRY, Jennifer K SPURWAY, Alan J LAENDE, Elise K REHAN, Saad ASTEPHEN WILSON, Janie L DUNBAR, Michael J EL-HAWARY, Ron A low-dose biplanar X-ray imager has RSA level precision in total knee arthroplasty |
title | A low-dose biplanar X-ray imager has RSA level precision in total knee arthroplasty |
title_full | A low-dose biplanar X-ray imager has RSA level precision in total knee arthroplasty |
title_fullStr | A low-dose biplanar X-ray imager has RSA level precision in total knee arthroplasty |
title_full_unstemmed | A low-dose biplanar X-ray imager has RSA level precision in total knee arthroplasty |
title_short | A low-dose biplanar X-ray imager has RSA level precision in total knee arthroplasty |
title_sort | low-dose biplanar x-ray imager has rsa level precision in total knee arthroplasty |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10688435/ https://www.ncbi.nlm.nih.gov/pubmed/38032252 http://dx.doi.org/10.2340/17453674.2023.19669 |
work_keys_str_mv | AT hurryjenniferk alowdosebiplanarxrayimagerhasrsalevelprecisionintotalkneearthroplasty AT spurwayalanj alowdosebiplanarxrayimagerhasrsalevelprecisionintotalkneearthroplasty AT laendeelisek alowdosebiplanarxrayimagerhasrsalevelprecisionintotalkneearthroplasty AT rehansaad alowdosebiplanarxrayimagerhasrsalevelprecisionintotalkneearthroplasty AT astephenwilsonjaniel alowdosebiplanarxrayimagerhasrsalevelprecisionintotalkneearthroplasty AT dunbarmichaelj alowdosebiplanarxrayimagerhasrsalevelprecisionintotalkneearthroplasty AT elhawaryron alowdosebiplanarxrayimagerhasrsalevelprecisionintotalkneearthroplasty AT hurryjenniferk lowdosebiplanarxrayimagerhasrsalevelprecisionintotalkneearthroplasty AT spurwayalanj lowdosebiplanarxrayimagerhasrsalevelprecisionintotalkneearthroplasty AT laendeelisek lowdosebiplanarxrayimagerhasrsalevelprecisionintotalkneearthroplasty AT rehansaad lowdosebiplanarxrayimagerhasrsalevelprecisionintotalkneearthroplasty AT astephenwilsonjaniel lowdosebiplanarxrayimagerhasrsalevelprecisionintotalkneearthroplasty AT dunbarmichaelj lowdosebiplanarxrayimagerhasrsalevelprecisionintotalkneearthroplasty AT elhawaryron lowdosebiplanarxrayimagerhasrsalevelprecisionintotalkneearthroplasty |