Cargando…

Impact of Dose Perturbations Around Brachytherapy Seeds in External-Beam Radiotherapy Planning: A Fundamental and Clinical Validation Using Treatment Planning System-Based Monte Carlo Simulations

Background This study evaluates dose perturbations caused by nonradioactive seeds in clinical cases by employing treatment planning system-based Monte Carlo (TPS-MC) simulation. Methodology We investigated dose perturbation using a water-equivalent phantom and 20 clinical cases of prostate cancer (1...

Descripción completa

Detalles Bibliográficos
Autores principales: Ogawa, Shuta, Yasui, Keisuke, Hayashi, Naoki, Saito, Yasunori, Hayashi, Shinya
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10689119/
https://www.ncbi.nlm.nih.gov/pubmed/38046495
http://dx.doi.org/10.7759/cureus.48041
_version_ 1785152304869015552
author Ogawa, Shuta
Yasui, Keisuke
Hayashi, Naoki
Saito, Yasunori
Hayashi, Shinya
author_facet Ogawa, Shuta
Yasui, Keisuke
Hayashi, Naoki
Saito, Yasunori
Hayashi, Shinya
author_sort Ogawa, Shuta
collection PubMed
description Background This study evaluates dose perturbations caused by nonradioactive seeds in clinical cases by employing treatment planning system-based Monte Carlo (TPS-MC) simulation. Methodology We investigated dose perturbation using a water-equivalent phantom and 20 clinical cases of prostate cancer (10 cases with seeds and 10 cases without seeds) treated at Fujita Health University Hospital, Japan. First, dose calculations for a simple geometry were performed using the RayStation MC algorithm for a water-equivalent phantom with and without a seed. TPS-independent Monte Carlo (full-MC) simulations and film measurements were conducted to verify the accuracy of TPS-MC simulation. Subsequently, dose calculations using TPS-MC were performed on CT images of clinical cases of prostate cancer with and without seeds, and the dose distributions were compared. Results In clinical cases, dose calculations using MC simulations revealed hotspots around the seeds. However, the size of the hotspot was not correlated with the number of seeds. The maximum difference in dose perturbation between TPS-MC simulations and film measurements was 3.9%, whereas that between TPS-MC simulations and full-MC simulations was 3.7%. The dose error of TPS-MC was negligible for multiple beams or rotational irradiation. Conclusions Hotspots were observed in dose calculations using TPS-MC performed on CT images of clinical cases with seeds. The dose calculation accuracy around the seeds using TPS-MC simulations was comparable to that of film measurements and full-MC simulations, with differences within 3.9%. Although the clinical impact of hotspots occurring around the seeds is minimal, utilizing MC simulations on TPSs can be beneficial to verify their presence.
format Online
Article
Text
id pubmed-10689119
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-106891192023-12-01 Impact of Dose Perturbations Around Brachytherapy Seeds in External-Beam Radiotherapy Planning: A Fundamental and Clinical Validation Using Treatment Planning System-Based Monte Carlo Simulations Ogawa, Shuta Yasui, Keisuke Hayashi, Naoki Saito, Yasunori Hayashi, Shinya Cureus Medical Physics Background This study evaluates dose perturbations caused by nonradioactive seeds in clinical cases by employing treatment planning system-based Monte Carlo (TPS-MC) simulation. Methodology We investigated dose perturbation using a water-equivalent phantom and 20 clinical cases of prostate cancer (10 cases with seeds and 10 cases without seeds) treated at Fujita Health University Hospital, Japan. First, dose calculations for a simple geometry were performed using the RayStation MC algorithm for a water-equivalent phantom with and without a seed. TPS-independent Monte Carlo (full-MC) simulations and film measurements were conducted to verify the accuracy of TPS-MC simulation. Subsequently, dose calculations using TPS-MC were performed on CT images of clinical cases of prostate cancer with and without seeds, and the dose distributions were compared. Results In clinical cases, dose calculations using MC simulations revealed hotspots around the seeds. However, the size of the hotspot was not correlated with the number of seeds. The maximum difference in dose perturbation between TPS-MC simulations and film measurements was 3.9%, whereas that between TPS-MC simulations and full-MC simulations was 3.7%. The dose error of TPS-MC was negligible for multiple beams or rotational irradiation. Conclusions Hotspots were observed in dose calculations using TPS-MC performed on CT images of clinical cases with seeds. The dose calculation accuracy around the seeds using TPS-MC simulations was comparable to that of film measurements and full-MC simulations, with differences within 3.9%. Although the clinical impact of hotspots occurring around the seeds is minimal, utilizing MC simulations on TPSs can be beneficial to verify their presence. Cureus 2023-10-31 /pmc/articles/PMC10689119/ /pubmed/38046495 http://dx.doi.org/10.7759/cureus.48041 Text en Copyright © 2023, Ogawa et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Medical Physics
Ogawa, Shuta
Yasui, Keisuke
Hayashi, Naoki
Saito, Yasunori
Hayashi, Shinya
Impact of Dose Perturbations Around Brachytherapy Seeds in External-Beam Radiotherapy Planning: A Fundamental and Clinical Validation Using Treatment Planning System-Based Monte Carlo Simulations
title Impact of Dose Perturbations Around Brachytherapy Seeds in External-Beam Radiotherapy Planning: A Fundamental and Clinical Validation Using Treatment Planning System-Based Monte Carlo Simulations
title_full Impact of Dose Perturbations Around Brachytherapy Seeds in External-Beam Radiotherapy Planning: A Fundamental and Clinical Validation Using Treatment Planning System-Based Monte Carlo Simulations
title_fullStr Impact of Dose Perturbations Around Brachytherapy Seeds in External-Beam Radiotherapy Planning: A Fundamental and Clinical Validation Using Treatment Planning System-Based Monte Carlo Simulations
title_full_unstemmed Impact of Dose Perturbations Around Brachytherapy Seeds in External-Beam Radiotherapy Planning: A Fundamental and Clinical Validation Using Treatment Planning System-Based Monte Carlo Simulations
title_short Impact of Dose Perturbations Around Brachytherapy Seeds in External-Beam Radiotherapy Planning: A Fundamental and Clinical Validation Using Treatment Planning System-Based Monte Carlo Simulations
title_sort impact of dose perturbations around brachytherapy seeds in external-beam radiotherapy planning: a fundamental and clinical validation using treatment planning system-based monte carlo simulations
topic Medical Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10689119/
https://www.ncbi.nlm.nih.gov/pubmed/38046495
http://dx.doi.org/10.7759/cureus.48041
work_keys_str_mv AT ogawashuta impactofdoseperturbationsaroundbrachytherapyseedsinexternalbeamradiotherapyplanningafundamentalandclinicalvalidationusingtreatmentplanningsystembasedmontecarlosimulations
AT yasuikeisuke impactofdoseperturbationsaroundbrachytherapyseedsinexternalbeamradiotherapyplanningafundamentalandclinicalvalidationusingtreatmentplanningsystembasedmontecarlosimulations
AT hayashinaoki impactofdoseperturbationsaroundbrachytherapyseedsinexternalbeamradiotherapyplanningafundamentalandclinicalvalidationusingtreatmentplanningsystembasedmontecarlosimulations
AT saitoyasunori impactofdoseperturbationsaroundbrachytherapyseedsinexternalbeamradiotherapyplanningafundamentalandclinicalvalidationusingtreatmentplanningsystembasedmontecarlosimulations
AT hayashishinya impactofdoseperturbationsaroundbrachytherapyseedsinexternalbeamradiotherapyplanningafundamentalandclinicalvalidationusingtreatmentplanningsystembasedmontecarlosimulations