Cargando…
Results of the Use of Bioabsorbable Magnesium Screws for Surgical Treatment of Mason Type II Radial Head Fractures
BACKGROUND: In Mason classification type II radial head fractures, compared to plate fixation, fixation with cannulated headless screws and absorbable pins has been reported to provide more favorable postoperative outcomes, including less postoperative limitation in range of motion. The fact that ra...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Orthopaedic Association
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10689227/ https://www.ncbi.nlm.nih.gov/pubmed/38045577 http://dx.doi.org/10.4055/cios23074 |
_version_ | 1785152326776913920 |
---|---|
author | Lee, Chul-Hyung Woo, Seungha Choi, Hyun Duck |
author_facet | Lee, Chul-Hyung Woo, Seungha Choi, Hyun Duck |
author_sort | Lee, Chul-Hyung |
collection | PubMed |
description | BACKGROUND: In Mason classification type II radial head fractures, compared to plate fixation, fixation with cannulated headless screws and absorbable pins has been reported to provide more favorable postoperative outcomes, including less postoperative limitation in range of motion. The fact that radial head fractures are less prone to weight-bearing during fracture union further supports the use of absorbable screws as a suitable alternative treatment option in radial head fractures. This study aimed to perform fixation through open reduction using bioabsorbable magnesium screws for Mason type II radial head fractures and to report radiographic and clinical results. METHODS: Among patients who visited the orthopedic department from April 2017 to August 2021, 22 with surgical indications were selected for participation. Radiographic tests were conducted at 2 weeks, 4 weeks, 8 weeks, 12 weeks, 6 months, and over 1 year after surgery to confirm the degree of bone union, reduction loss, and degree of H(2) gas production. The Disabilities of the Arm, Shoulder and Hand (DASH) score, Mayo Elbow Performance Score (MEPS), hand grip power, and range of joint motion were measured at the 6-month follow-up to evaluate the clinical efficacy of the operation. RESULTS: Bone union was confirmed in all 22 cases, and the mean time to union was 10.2 weeks. DASH score was 22.27 on average and no patients complained of significant discomfort after the surgery. The mean MEPS was 91.1. The hand grip power of the affected hand was similar to that of the unaffected hand, being 1.19% weaker on average. These differences reached statistical significance (p = 0.002). The range of elbow joint motion was measured: mean flexion, 146.1°; mean extension, 1.4°; mean pronation, 88.2°; and mean supination, 87.9°. CONCLUSIONS: In treating Mason type II radial head fractures, the use of bioabsorbable screws made of magnesium showed satisfactory results in radiographic and clinical evaluations. Magnesium bioabsorbable screws can maintain sufficient stability at the fracture site and have the advantage of avoiding secondary operation for the removal of internal fixation devices. |
format | Online Article Text |
id | pubmed-10689227 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | The Korean Orthopaedic Association |
record_format | MEDLINE/PubMed |
spelling | pubmed-106892272023-12-02 Results of the Use of Bioabsorbable Magnesium Screws for Surgical Treatment of Mason Type II Radial Head Fractures Lee, Chul-Hyung Woo, Seungha Choi, Hyun Duck Clin Orthop Surg Original Article BACKGROUND: In Mason classification type II radial head fractures, compared to plate fixation, fixation with cannulated headless screws and absorbable pins has been reported to provide more favorable postoperative outcomes, including less postoperative limitation in range of motion. The fact that radial head fractures are less prone to weight-bearing during fracture union further supports the use of absorbable screws as a suitable alternative treatment option in radial head fractures. This study aimed to perform fixation through open reduction using bioabsorbable magnesium screws for Mason type II radial head fractures and to report radiographic and clinical results. METHODS: Among patients who visited the orthopedic department from April 2017 to August 2021, 22 with surgical indications were selected for participation. Radiographic tests were conducted at 2 weeks, 4 weeks, 8 weeks, 12 weeks, 6 months, and over 1 year after surgery to confirm the degree of bone union, reduction loss, and degree of H(2) gas production. The Disabilities of the Arm, Shoulder and Hand (DASH) score, Mayo Elbow Performance Score (MEPS), hand grip power, and range of joint motion were measured at the 6-month follow-up to evaluate the clinical efficacy of the operation. RESULTS: Bone union was confirmed in all 22 cases, and the mean time to union was 10.2 weeks. DASH score was 22.27 on average and no patients complained of significant discomfort after the surgery. The mean MEPS was 91.1. The hand grip power of the affected hand was similar to that of the unaffected hand, being 1.19% weaker on average. These differences reached statistical significance (p = 0.002). The range of elbow joint motion was measured: mean flexion, 146.1°; mean extension, 1.4°; mean pronation, 88.2°; and mean supination, 87.9°. CONCLUSIONS: In treating Mason type II radial head fractures, the use of bioabsorbable screws made of magnesium showed satisfactory results in radiographic and clinical evaluations. Magnesium bioabsorbable screws can maintain sufficient stability at the fracture site and have the advantage of avoiding secondary operation for the removal of internal fixation devices. The Korean Orthopaedic Association 2023-12 2023-10-25 /pmc/articles/PMC10689227/ /pubmed/38045577 http://dx.doi.org/10.4055/cios23074 Text en Copyright © 2023 by The Korean Orthopaedic Association https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Lee, Chul-Hyung Woo, Seungha Choi, Hyun Duck Results of the Use of Bioabsorbable Magnesium Screws for Surgical Treatment of Mason Type II Radial Head Fractures |
title | Results of the Use of Bioabsorbable Magnesium Screws for Surgical Treatment of Mason Type II Radial Head Fractures |
title_full | Results of the Use of Bioabsorbable Magnesium Screws for Surgical Treatment of Mason Type II Radial Head Fractures |
title_fullStr | Results of the Use of Bioabsorbable Magnesium Screws for Surgical Treatment of Mason Type II Radial Head Fractures |
title_full_unstemmed | Results of the Use of Bioabsorbable Magnesium Screws for Surgical Treatment of Mason Type II Radial Head Fractures |
title_short | Results of the Use of Bioabsorbable Magnesium Screws for Surgical Treatment of Mason Type II Radial Head Fractures |
title_sort | results of the use of bioabsorbable magnesium screws for surgical treatment of mason type ii radial head fractures |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10689227/ https://www.ncbi.nlm.nih.gov/pubmed/38045577 http://dx.doi.org/10.4055/cios23074 |
work_keys_str_mv | AT leechulhyung resultsoftheuseofbioabsorbablemagnesiumscrewsforsurgicaltreatmentofmasontypeiiradialheadfractures AT wooseungha resultsoftheuseofbioabsorbablemagnesiumscrewsforsurgicaltreatmentofmasontypeiiradialheadfractures AT choihyunduck resultsoftheuseofbioabsorbablemagnesiumscrewsforsurgicaltreatmentofmasontypeiiradialheadfractures |